We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a…

Instrumentation and Detectors · Physics 2015-10-28 L. Arazi , A. E. C. Coimbra , E. Erdal , I. Israelashvili , M. L. Rappaport , S. Shchemelinin , D. Vartsky , J. M. F. dos Santos , A. Breskin

Particle detectors that use liquid xenon (LXe) as detection medium are among the leading technologies in the search for dark matter weakly interacting massive particles (WIMPs). A key enabling element has been the low-energy detection…

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their…

Instrumentation and Methods for Astrophysics · Physics 2021-01-22 D. S. Akerib , A. K. Al Musalhi , S. K. Alsum , C. S. Amarasinghe , A. Ames , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , X. Bai , J. Balajthy , S. Balashov , J. Bang , J. W. Bargemann , D. Bauer , A. Baxter , P. Beltrame , E. P. Bernard , A. Bernstein , A. Bhatti , A. Biekert , T. P. Biesiadzinski , H. J. Birch , G. M. Blockinger , B. Boxer , C. A. J. Brew , P. Brás , S. Burdin , J. K. Busenitz , M. Buuck , R. Cabrita , M. C. Carmona-Benitez , M. Cascella , C. Chan , N. I. Chott , A. Cole , M. V. Converse , A. Cottle , G. Cox , J. E. Cutter , C. E. Dahl , L. de Viveiros , J. E. Y. Dobson , E. Druszkiewicz , S. R. Eriksen , A. Fan , S. Fayer , N. M. Fearon , S. Fiorucci , H. Flaecher , E. D. Fraser , T. Fruth , R. J. Gaitskell , J. Genovesi , C. Ghag , E. Gibson , S. Gokhale , M. G. D. van der Grinten , C. B. Gwilliam , C. R. Hall , S. J. Haselschwardt , S. A. Hertel , M. Horn , D. Q. Huang , C. M. Ignarra , O. Jahangir , R. S. James , W. Ji , J. Johnson , A. C. Kaboth , A. C. Kamaha , K. Kamdin , K. Kazkaz , D. Khaitan , A. Khazov , I. Khurana , D. Kodroff , L. Korley , E. V. Korolkova , H. Kraus , S. Kravitz , L. Kreczko , B. Krikler , V. A. Kudryavtsev , E. A. Leason , K. T. Lesko , C. Levy , J. Li , J. Liao , J. Lin , A. Lindote , R. Linehan , W. H. Lippincott , X. Liu , M. I. Lopes , E. Lopez Asamar , B. López Paredes , W. Lorenzon , S. Luitz , P. A. Majewski , A. Manalaysay , L. Manenti , R. L. Mannino , N. Marangou , M. E. McCarthy , D. N. McKinsey , J. McLaughlin , E. H. Miller , E. Mizrachi , A. Monte , M. E. Monzani , J. A. Morad , J. D. Morales Mendoza , E. Morrison , B. J. Mount , A. St. J. Murphy , D. Naim , A. Naylor , C. Nedlik , H. N. Nelson , F. Neves , J. A. Nikoleyczik , I. Olcina , K. C. Oliver-Mallory , S. Pal , K. J. Palladino , J. Palmer , N. Parveen , E. K. Pease , B. Penning , G. Pereira , A. Piepke , Y. Qie , J. Reichenbacher , C. A. Rhyne , A. Richards , Q. Riffard , G. R. C. Rischbieter , R. Rosero , P. Rossiter , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , P. R. Scovell , S. Shaw , T. A. Shutt , J. J. Silk , C. Silva , R. Smith , M. Solmaz , V. N. Solovov , P. Sorensen , I. Stancu , A. Stevens , K. Stifter , B. Suerfu , T. J. Sumner , N. Swanson , M. Szydagis , W. C. Taylor , R. Taylor , D. J. Temples , P. A. Terman , D. R. Tiedt , M. Timalsina , W. H. To , M. Tripathi , D. R. Tronstad , W. Turner , U. Utku , A. Vaitkus , B. Wang , J. J. Wang , W. Wang , J. R. Watson , R. C. Webb , R. G. White , T. J. Whitis , M. Williams , F. L. H. Wolfs , D. Woodward , C. J. Wright , X. Xiang , J. Xu , M. Yeh , P. Zarzhitsky

The fastCAT application uses pre-calculated Monte Carlo (MC) CBCT phantom-specific scatter and detector response functions to reduce simulation time for megavoltage (MV) and kilovoltage (kV) CBCT imaging. Pre-calculated x-ray beam energy…

Medical Physics · Physics 2021-09-15 Jericho O'Connell , Magdalena Bazalova-Carter

XENON10 is a new direct dark matter detection experiment using liquid xenon as target for weakly interacting, massive particles (WIMPs). A two-phase (liquid/gas) time projection chamber with 15 kg fiducial mass has been installed in a…

Astrophysics · Physics 2008-11-26 Laura Baudis

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon

The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the…

Instrumentation and Methods for Astrophysics · Physics 2018-06-13 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , B. Antunes , F. Arneodo , M. Balata , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , A. Breskin , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , A. Chiarini , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , R. Corrieri , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , J. -M. Disdier , M. Doets , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Florin , D. Front , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , K. -L. Giboni , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , C. Huhmann , R. Itay , A. James , B. Kaminsky , S. Kazama , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , R. Maier , A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. Morå , M. Murra , J. Naganoma , K. Ni , U. Oberlack , D. Orlandi , R. Othegraven , P. Pakarha , S. Parlati , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , V. Pizzella , M. -C. Piro , G. Plante , N. Priel , D. Ramírez García , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , J. M. F. dos Santos , R. Saldahna , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , M. Stern , A. Stein , D. Tatananni , L. Tatananni , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , M. Vargas , O. Wack , R. Walet , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , C. Wittweg , J. Wulf , J. Ye , Y. Zhang

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

Dual-phase time projection chambers (TPCs) filled with the liquid noble gas xenon (LXe) are currently the most sensitive detectors searching for interactions of WIMP dark matter in a laboratory-based experiment. This is achieved by…

Instrumentation and Methods for Astrophysics · Physics 2014-08-08 Marc Schumann

The feasibility study of a new technique for thermal neutron detection using a Timepix3 camera (TPX3Cam) with custom-made optical add-ons operated in event-mode data acquisition is presented. The camera has a spatial resolution of ~ 16 um…

X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique of x-ray photons, which can be used to sense different elements or nanoparticle (NP) agents inside deep samples or tissues. XFCT has been an active research…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Yile Fang , Michael Lun , Changqing Li

The NeXT mission has been proposed to study high-energy non-thermal phenomena in the universe. The high-energy response of the super mirror will enable us to perform the first sensitive imaging observations up to 80 keV. The focal plane…

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing…

The XENON1T experiment is the most recent stage of the XENON Dark Matter Search, aiming for the direct detection of Weakly Interacting Massive Particles (WIMPs). To reach its projected sensitivity, the background has to be reduced by two…

Instrumentation and Detectors · Physics 2017-06-28 Christopher Geis , Cyril Grignon , Uwe Oberlack , Diego Ramírez García , Quirin Weitzel

nEXO is a proposed experiment to search for the neutrino-less double beta decay ($0\nu\beta\beta$) of $^{136}$Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form…

Instrumentation and Detectors · Physics 2019-10-21 Z. Li , W. R. Cen , A. Robinson , D. C. Moore , L. J. Wen , A. Odian , S. Al Kharusi , G. Anton , I. J. Arnquist , I. Badhrees , P. S. Barbeau , D. Beck , V. Belov , T. Bhatta , J. P. Brodsky , E. Brown , T. Brunner , E. Caden , G. F. Cao , L. Cao , C. Chambers , B. Chana , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , A. Craycraft , J. Dalmasson , T. Daniels , L. Darroch , S. J. Daugherty , A. De St. Croix , A. Der Mesrobian-Kabakian , R. DeVoe , M. L. Di Vacri , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , J. Echevers , M. Elbeltagi , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Ferrara , S. Feyzbakhsh , R. Fontaine , A. Fucarino , G. Gallina , P. Gautam , G. Giacomini , D. Goeldi , R. Gornea , G. Gratta , E. V. Hansen , M. Heffner , E. W. Hoppe , J. Hößl , A. House , M. Hughes , A. Iverson , A. Jamil , M. J. Jewell , X. S. Jiang , A. Karelin , L. J. Kaufman , D. Kodroff , T. Koffas , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , K. G. Leach , B. G. Lenardo , D. S. Leonard , G. Li , S. Li , C. Licciardi , Y. H. Lin , P. Lv , R. MacLellan , T. McElroy , M. Medina-Peregrina , T. Michel , B. Mong , K. Murray , P. Nakarmi , C. R. Natzke , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , O. Nusair , K. Odgers , M. Oriunno , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , V. Radeka , E. Raguzin , S. Rescia , F. Retière , M. Richman , T. Rossignol , P. C. Rowson , N. Roy , J. Runge , R. Saldanha , S. Sangiorgio , K. Skarpaas VIII , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , T. I. Totev , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , S. Viel , G. Visser , C. Vivo-Vilches , J. -L. Vuilleumier , M. Wagenpfeil , M. Walent , Q. Wang , M. Ward , J. Watkins , M. Weber , W. Wei , U. Wichoski , S. X. Wu , W. H. Wu , X. Wu , Q. Xia , H. Yang , L. Yang , Y. -R. Yen , O. Zeldovich , J. Zhao , Y. Zhou , T. Ziegler

The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles,…

Instrumentation and Detectors · Physics 2022-01-12 The LUX-ZEPLIN , Collaboration , : , D. S. Akerib , A. K. Al Musalhi , S. K. Alsum , C. S. Amarasinghe , A. Ames , T. J. Anderson , N. Angelides , H. M. Araujo , J. E. Armstrong , M. Arthurs , X. Bai , J. Balajthy , S. Balashov , J. Bang , J. W. Bargemann , D. Bauer , A. Baxter , P. Beltrame , E. P. Bernard , A. Bernstein , A. Bhatti , A. Biekert , T. P. Biesiadzinski , H. J. Birch , G. M. Blockinger , E. Bodnia , B. Boxer , C. A. J. Brew , P. Bras , S. Burdin , J. K. Busenitz , M. Buuck , R. Cabrita , M. C. Carmona-Benitez , M. Cascella , C. Chan , N. I. Chott , A. Cole , M. V. Converse , A. Cottle , G. Cox , O. Creaner , J. E. Cutter , C. E. Dahl , L. de Viveiros , J. E. Y. Dobson , E. Druszkiewicz , S. R. Eriksen , A. Fan , S. Fayer , N. M. Fearon , S. Fiorucci , H. Flaecher , E. D. Fraser , T. Fruth , R. J. Gaitskell , J. Genovesi , C. Ghag , E. Gibson , S. Gokhale , M. G. D. van der Grinten , C. B. Gwilliam , C. R. Hall , S. J. Haselschwardt , S. A. Hertel , M. Horn , D. Q. Huang , C. M. Ignarra , O. Jahangir , R. S. James , W. Ji , J. Johnson , A. C. Kaboth , A. C. Kamaha , K. Kamdin , K. Kazkaz , D. Khaitan , A. Khazov , I. Khurana , D. Kodroff , L. Korley , E. V. Korolkova , H. Kraus , S. Kravitz , L. Kreczko , B. Krikler , V. A. Kudryavtsev , E. A. Leason , J. Lee , D. S. Leonard , K. T. Lesko , C. Levy , J. Liao , J. Lin , A. Lindote , R. Linehan , W. H. Lippincott , X. Liu , M. I. Lopes , E. Lopez Asamar , B. Lopez Paredes , W. Lorenzon , S. Luitz , P. A. Majewski , A. Manalaysay , L. Manenti , R. L. Mannino , N. Marangou , M. E. McCarthy , D. N. McKinsey , J. McLaughlin , E. H. Miller , E. Mizrachi , A. Monte , M. E. Monzani , J. A. Morad , J. D. Morales Mendoza , E. Morrison , B. J. Mount , A. St. J. Murphy , D. Naim , A. Naylor , C. Nedlik , H. N. Nelson , F. Neves , J. A. Nikoleyczik , A. Nilima , I. Olcina , K. C. Oliver-Mallory , S. Pal , K. J. Palladino , J. Palmer , S. Patton , N. Parveen , E. K. Pease , B. Penning , G. Pereira , A. Piepke , Y. Qie , J. Reichenbacher , C. A. Rhyne , A. Richards , Q. Riffard , G. R. C. Rischbieter , R. Rosero , P. Rossiter , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , P. R. Scovell , S. Shaw , T. A. Shutt , J. J. Silk , C. Silva , R. Smith , M. Solmaz , V. N. Solovov , P. Sorensen , J. Soria , I. Stancu , A. Stevens , K. Stifter , B. Suerfu , T. J. Sumner , N. Swanson , M. Szydagis , W. C. Taylor , R. Taylor , D. J. Temples , P. A. Terman , D. R. Tiedt , M. Timalsina , W. H. To , D. R. Tovey , M. Tripathi , D. R. Tronstad , W. Turner , U. Utku , A. Vaitkus , B. Wang , J. J. Wang , W. Wang , J. R. Watson , R. C. Webb , R. G. White , T. J. Whitis , M. Williams , F. L. H. Wolfs , D. Woodward , C. J. Wright , X. Xiang , J. Xu , M. Yeh , P. Zarzhitsky

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in…

Instrumentation and Detectors · Physics 2025-08-14 XENON Collaboration , E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , M. Balata , L. Baudis , A. L. Baxter , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , E. J. Brookes , A. Brown , S. Bruenner , G. Bruno , R. Budnik , T. K. Bui , C. Cai , J. M. R. Cardoso , F. Cassese , A. Chiarini , D. Cichon , A. P. Cimental Chavez , A. P. Colijn , J. Conrad , R. Corrieri , J. J. Cuenca-García , J. P. Cussonneau , O. Dadoun , V. D'Andrea , M. P. Decowski , B. De Fazio , P. Di Gangi , S. Diglio , J. M. Disdier , D. Douillet , K. Eitel , A. Elykov , S. Farrell , A. D. Ferella , C. Ferrari , H. Fischer , M. Flierman , S. Form , D. Front , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , R. Gardner , N. Garroum , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guerzoni , M. Guida , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , J. Howlett , C. Huhmann , M. Iacovacci , G. Iaquaniello , L. Iven , Y. Itow , J. Jakob , F. Joerg , A. Joy , M. Kara , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , F. Kuger , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , P. Martella , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , E. Mele , M. Messina , R. Michinelli , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , S. Nisi , U. Oberlack , D. Orlandi , R. Othegraven , B. Paetsch , J. Palacio , S. Parlati , P. Paschos , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , J. Qi , J. Qin , D. Ramírez García , M. Rynge , J. Shi , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , E. Shockley , M. Silva , H. Simgen , J. Stephen , M. Stern , B. K. Stillwell , A. Takeda , P. -L. Tan , D. Tatananni , A. Terliuk , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong , T. Zhu

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow…

We present systematic case studies to investigate the sensitivity of axion searches by liquid xenon detectors, using the axio-electric effect (analogue of the photoelectric effect) on xenon atoms. Liquid xenon is widely considered to be one…

Cosmology and Nongalactic Astrophysics · Physics 2015-06-11 K. Arisaka , P. Beltrame , C. Ghag , J. Kaidi , K. Lung , A. Lyashenko , R. D. Peccei , P. Smith , K. Ye

We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment…