English
Related papers

Related papers: Signal and noise simulation of CUORE bolometric de…

200 papers

Solid state detectors and cryogenic detectors are widely employed in rare event searches, such as direct Dark Matter detection or Coherent Neutrino Nucleus Scattering experiments. The excellent sensitivity and, consequently, their low…

Instrumentation and Detectors · Physics 2019-06-20 M. Mancuso , A. Bento , N. Ferreiro Iachellini , D. Hauff , F. Petricca , F. Pröbst , J. Rothe , R. Strauss

Experiments searching for rare events, such as neutrinoless double beta decay and interactions of dark matter candidates, require extremely low levels of background. When these experiments are performed using macro-bolometers, radioactive…

CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to…

We report on the measurement of the two-neutrino double beta decay half-life of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of TeO$_2$, the half-life is determined to be $T_{1/2}^{2\nu}$ = [8.2 $\pm$ 0.2…

Nuclear Experiment · Physics 2017-02-24 CUORE Collaboration , C. Alduino , K. Alfonso , D. R. Artusa , F. T. Avignone , O. Azzolini , T. I. Banks , G. Bari , J. W. Beeman , F. Bellini , A. Bersani , M. Biassoni , A. Branca , C. Brofferio , C. Bucci , A. Camacho , A. Caminata , L. Canonica , X. G. Cao , S. Capelli , L. Cappelli , L. Carbone , L. Cardani , P. Carniti , N. Casali , L. Cassina , D. Chiesa , N. Chott , M. Clemenza , S. Copello , C. Cosmelli , O. Cremonesi , R. J. Creswick , J. S. Cushman , A. D'Addabbo , I. Dafinei , C. J. Davis , S. Dell'Oro , M. M. Deninno , S. Di Domizio , M. L. Di Vacri , A. Drobizhev , D. Q. Fang , M. Faverzani , G. Fernandes , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , B. K. Fujikawa , A. Giachero , L. Gironi , A. Giuliani , L. Gladstone , P. Gorla , C. Gotti , T. D. Gutierrez , E. E. Haller , K. Han , E. Hansen , K. M. Heeger , R. Hennings-Yeomans , K. P. Hickerson , H. Z. Huang , R. Kadel , G. Keppel , Yu. G. Kolomensky , A. Leder , C. Ligi , K. E. Lim , X. Liu , Y. G. Ma , M. Maino , L. Marini , M. Martinez , R. H. Maruyama , Y. Mei , N. Moggi , S. Morganti , P. J. Mosteiro , T. Napolitano , C. Nones , E. B. Norman , A. Nucciotti , T. O'Donnell , F. Orio , J. L. Ouellet , C. E. Pagliarone , M. Pallavicini , V. Palmieri , L. Pattavina , M. Pavan , G. Pessina , V. Pettinacci , G. Piperno , C. Pira , S. Pirro , S. Pozzi , E. Previtali , C. Rosenfeld , C. Rusconi , S. Sangiorgio , D. Santone , N. D. Scielzo , V. Singh , M. Sisti , A. R. Smith , L. Taffarello , M. Tenconi , F. Terranova , C. Tomei , S. Trentalange , M. Vignati , S. L. Wagaarachchi , B. S. Wang , H. W. Wang , J. Wilson , L. A. Winslow , T. Wise , A. Woodcraft , L. Zanotti , G. Q. Zhang , B. X. Zhu , S. Zimmermann , S. Zucchelli

CUPID is a proposed future ton-scale bolometric neutrinoless double beta decay ($0\nu\beta\beta$) experiment to probe the Majorana nature of neutrinos and discover Lepton Number Violation in the so-called inverted hierarchy region of the…

Instrumentation and Detectors · Physics 2015-04-15 The CUPID Interest Group

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of…

Instrumentation and Detectors · Physics 2021-07-13 A. Armatol , E. Armengaud , W. Armstrong , C. Augier , F. T. Avignone , O. Azzolini , A. Barabash , G. Bari , A. Barresi , D. Baudin , F. Bellini , G. Benato , M. Beretta , L. Bergé , M. Biassoni , J. Billard , V. Boldrini , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , A. Cazes , E. Celi , C. Chang , M. Chapellier , A. Charrier , D. Chiesa , M. Clemenza , I. Colantoni , F. Collamati , S. Copello , O. Cremonesi , R. J. Creswick , A. Cruciani , A. D'Addabbo , G. D'Imperio , I. Dafinei , F. A. Danevich , M. de Combarieu , M. De Jesus , P. de Marcillac , S. Dell'Oro , S. Di Domizio , V. Dompè , A. Drobizhev , L. Dumoulin , G. Fantini , M. Faverzani , E. Ferri , F. Ferri , F. Ferroni , E. Figueroa-Feliciano , J. Formaggio , A. Franceschi , C. Fu , S. Fu , B. K. Fujikawa , J. Gascon , A. Giachero , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , P. Gras , M. Gros , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , D. L. Helis , H. Z. Huang , R. G. Huang , L. Imbert , J. Johnston , A. Juillard , G. Karapetrov , G. Keppel , H. Khalife , V. V. Kobychev , Yu. G. Kolomensky , S. Konovalov , Y. Liu , P. Loaiza , L. Ma , M. Madhukuttan , F. Mancarella , R. Mariam , L. Marini , S. Marnieros , M. Martinez , R. H. Maruyama , B. Mauri , D. Mayer , Y. Mei , S. Milana , D. Misiak , T. Napolitano , M. Nastasi , X. F. Navick , J. Nikkel , R. Nipoti , S. Nisi , C. Nones , E. B. Norman , V. Novosad , I. Nutini , T. O'Donnell , E. Olivieri , C. Oriol , J. L. Ouellet , S. Pagan , C. Pagliarone , L. Pagnanini , P. Pari , L. Pattavina , B. Paul , M. Pavan , H. Peng , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , D. V. Poda , T. Polakovic , O. G. Polischuk , S. Pozzi , E. Previtali , A. Puiu , A. Ressa , R. Rizzoli , C. Rosenfeld , C. Rusconi , V. Sanglard , J. Scarpaci , B. Schmidt , V. Sharma , V. Shlegel , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , O. Tellier , C. Tomei , V. I. Tretyak , A. Tsymbaliuk , M. Velazquez , K. J. Vetter , S. L. Wagaarachchi , G. Wang , L. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , M. Xue , L. Yan , J. Yang , V. Yefremenko , V. Yumatov , M. M. Zarytskyy , J. Zhang , A. Zolotarova , S. Zucchelli

The Cryogenic Rare Event Search with Superconducting Thermometers Phase II (CRESST-II) at the L.N.G.S in Italy is searching for Dark Matter using low-temperature calorimeters. These detectors allow to discriminate different particles by…

We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution…

Various dark matter search experiments employ phonon-based crystal detectors operated at cryogenic temperatures. Some of these detectors, including certain silicon detectors used by the SuperCDMS Collaboration, are able to achieve…

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0\nu\beta\beta$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual…

130Te is one of the candidates for the search for neutrinoless double beta decay. It is currently planned to be used in two experiments: CUORE and SNO+. In the CUORE experiment TeO2 crystals cooled at cryogenic temperatures will be used. In…

Instrumentation and Detectors · Physics 2014-11-24 V. Lozza , J. Petzoldt

A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…

Applied Physics · Physics 2020-08-26 Joris Vincent van Heijningen

Thermal conductivity measurement techniques for materials with nanoscale dimensions require fabrication of very complicated devices or their applicability is limited to a class of materials. Discovery of new methods with high thermal…

The standard non-equilibrium theory of noise in ideal bolometers and microcalorimeters fails to predict the performance of real devices due to additional effects that become important at low temperature. In this paper we extend the theory…

Astrophysics · Physics 2009-11-07 M. Galeazzi , D. McCammon

Cryogenic detectors are at the forefront of rare-event search experiments, including direct detection of dark matter, coherent elastic neutrino-nucleus scattering, neutrinoless double-beta decay, and searches for fractionally charged…

High Energy Physics - Experiment · Physics 2025-12-03 S. Das , R. Dey , V. K. S. Kashyap , B. Mohanty , D. Mondal , S. Banik , M. Chaudhuri , V. Iyer

We study the current noise through an unbiased quantum electron pump and its mesoscopic fluctuations for arbitrary temperatures and beyond the bilinear response. In the bilinear regime, we find the full distributions of the noise power and…

Mesoscale and Nanoscale Physics · Physics 2009-11-07 M. L. Polianski , M. G. Vavilov , P. W. Brouwer

Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range.…

In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…

Instrumentation and Detectors · Physics 2018-10-17 Richard Wigmans

Low-temperature detectors often use mechanical coolers as part of the cooling chain in order to reach sub-Kelvin operating temperatures. The microphonics noise caused by the mechanical coolers is a general and inherent issue for these…

Instrumentation and Methods for Astrophysics · Physics 2023-03-03 R. Imamura , H. Awaki , M. Tsujimoto , S. Yamada , F. S. Porter , C. A. Kilbourne , R. L. Kelley , Y. Takei

In the framework of the ``ULTIMA'' project, we use ultra cold superfluid 3He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after…

Instrumentation and Detectors · Physics 2009-11-13 J. Elbs , Yu. M. Bunkov , E. Collin , H. Godfrin , O. Suvorova