Related papers: Thermal architecture for the SPIDER flight cryosta…

200 papers

A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact…

We report the instrumentation and experimental results of a cryogenic scanning microwave impedance microscope. The microwave probe and the scanning stage are located inside the variable temperature insert of a helium cryostat. Microwave…

Mesoscale and Nanoscale Physics · Physics 2011-05-24 Worasom Kundhikanjana , Keji Lai , Michael A. Kelly , Zhi-Xun Shen

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five…

Accelerator Physics · Physics 2023-07-18 William Soyars , Tomasz Banaszkiewicz , Ram Dhuley

We propose a high thermal conductivity infrared (IR) filter using alumina for use in millimeter wave detection systems. We constructed a prototype two-layer anti-reflection (AR) coated alumina filter with a diameter of 100mm and a thickness…

Instrumentation and Methods for Astrophysics · Physics 2015-06-18 Yuki Inoue , Tomotake Matsumura , Masashi Hazumi , Adrian T. Lee , Takahiro Okamura , Aritoki Suzuki , Takayuki Tomaru , Hiroshi Yamaguchi

Semiconductor integrated circuits operated at cryogenic temperature will play an essential role in quantum computing architectures. These can offer equivalent or superior performance to their room-temperature counterparts while enabling a…

Mesoscale and Nanoscale Physics · Physics 2025-07-18 Jonathan Eastoe , Grayson M. Noah , Debargha Dutta , Alessandro Rossi , Jonathan D. Fletcher , Alberto Gomez-Saiz

We perform the characterization and modeling of a floating-gate device realized with a commercial 350-nm CMOS technology at cryogenic temperature. The programmability of the device offers a solution in the realization of a precise and…

Applied Physics · Physics 2021-10-25 Michele Castriotta , Enrico Prati , Giorgio Ferrari

Cryogenic ultra-stable lasers have extremely low thermal noise limits and frequency drifts, but they are more seriously affected by vibration noise from cryostats. Main material candidates for cryogenic ultra-stable cavities include silicon…

Instrumentation and Detectors · Physics 2023-05-17 Leilei He , Jingxuan Zhang , Zhiyuan Wang , Jialu Chang , Qiyue Wu , Zehuang Lu , Jie Zhang

Current and future experiments observing the cosmic microwave background require a detailed understanding of optical performance at cryogenic temperatures. Pre-deployment analysis of optics can be performed in custom-engineered cryogenic…

The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced…

Instrumentation and Detectors · Physics 2022-10-05 S. Ceravolo , F. Colao , C. Curatolo , E. Di Meco , E. Diociaiuti , D. Lucchesi , D. Paesani , N. Pastrone , A. Saputi , I. Sarra , L. Sestini , D. Tagnani

A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their…

Instrumentation and Detectors · Physics 2016-11-17 John G. Hartnett , Nitin R. Nand , Chao Wang , Jean-Michel Le Floch

We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…

Instrumentation and Methods for Astrophysics · Physics 2012-05-01 M. Hasegawa , O. Tajima , Y. Chinone , M. Hazumi , K. Ishidoshiro , M. Nagai

SPIDER is the prototype ion source of MITICA, the full-size neutral beam heating system conceived for the ITER tokamak. It includes eight drivers to heat and sustain the inductively coupled plasma (ICP). Owing to their near cylindrical…

Plasma Physics · Physics 2023-05-17 D. López-Bruna , P. Jain , M. Recchia , B. Zaniol , E. Sartori , C. Poggi , V. Candeloro , G. Serianni , P. Veltri

Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven…

Instrumentation and Detectors · Physics 2023-10-26 Constantin Schuster , Sebastian Kempf

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1…

Instrumentation and Detectors · Physics 2022-10-12 Christophe Fluhr , Benoît Dubois , Guillaume Le Tetu , Valerie Soumann , Julien Paris , Enrico Rubiola , Vincent Giordano

One of the standard composite insulation systems for cryogenic applications consists of a layer of hollow glass microspheres (HGMs) followed by a layer of variable density multilayer insulation (VDMLI) comprised of various internal…

Applied Physics · Physics 2024-09-26 Ritayan Mukherjee , Arun Srinivasan

We present a simple layout of a fast cooling system for liquids in sealed containers utilizing the large temperature gradients of cold nitrogen gas. Our system is optimized for about 20 cylindrical containers of 500 cm3 but the setup allows…

Instrumentation and Detectors · Physics 2017-02-24 Dirk Schulze Grachtrup , Mathias Kraken , Niklas van Elten , Stefan Süllow

Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is…

KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We…

Instrumentation and Detectors · Physics 2022-07-05 Rishabh Bajpai , Takayuki Tomaru , Nobuhiro Kimura , Takafumi Ushiba , Kazuhiro Yamamoto , Toshikazu Suzuki , Tohru Honda

A thermal heat switch has been developed intended for cryogenic space applications operating around 100 K. The switch was designed to separate two pulse tube cold heads that cool a common focal plane array. Two cold heads are used for…

Instrumentation and Detectors · Physics 2013-11-26 Marc Dietrich , Andreas Euler , Günter Thummes