Related papers: Nuclear recoil scintillation and ionisation yields…
We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm,…
Liquid xenon-based direct detection dark matter experiments have recently expanded their searches to include high-energy nuclear recoil events as motivated by effective field theory dark matter and inelastic dark matter interaction models,…
The ionization yield in the two-phase liquid xenon dark-matter detector has been studied in keV nuclear-recoil energy region. The newly-obtained nuclear quenching as well as the recently-measured average energy required to produce an…
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear…
Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\sim$MeV neutrinos. Such experiments expect to measure…
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $\alpha$-Be neutron sources…
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and…
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative…
We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber…
We present the results of the first experimental study of ionization yield of electron recoils with energies below 100 keV produced in liquid xenon by the isotopes: 37Ar, 83mKr, 241Am, 129Xe, 131Xe. It is confirmed by a direct measurement…
Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for…
This note presents revised detector parameters applicable to data from the First Science Run of the ZEPLIN-III dark matter experiment; these datasets were acquired in 2008 and reanalised in 2011. This run demonstrated electron recoil…
We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band…
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron…
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the…
The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by…
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which…
The Noble Element Simulation Technique (NEST) is an exhaustive collection of models explaining both the scintillation light and ionization yields of noble elements as a function of particle type (nuclear recoil, electron recoil, alphas),…