Related papers: Adapting a Cryogenic Sapphire Oscillator for Very …
We have carried out full imaging simulation studies to explore the impact of frequency standards in millimeter and sub-millimeter Very Long Baseline Interferometry (VLBI), focusing on the coherence time and sensitivity. In particular, we…
Since its observation in 2019, the first image of a super-massive black hole using Very Long Baseline Interferometry (VLBI) with an Earth-scale baseline has generated much scientific and public interest, including the possible extension of…
We describe a new method which achieves high precision Very Long Baseline Interferometry (VLBI) astrometry in observations at millimeter wavelengths. It combines fast frequency-switching observations, to correct for the dominant…
The cryogenic sapphire oscillator (CSO) is a highly specialized machine, which delivers a reference signal exhibiting the lowest frequency fluctuations. For the best units, the Allan deviation (ADEV) is <1e-15 for integration time between 1…
Extension of radio interferometric baselines into space is inevitable if a diffraction-limited angular resolution defined by the Earth diameter at a given observing wavelength limits a pursuit of specific scientific goals. This was…
Very long baseline interferometry (VLBI) provides the resolution needed to make precision measurements of a pulsar's parallax and proper motion. In making these measurements, the astronomer is faced with difficult calibration problems and a…
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we…
Very long baseline interferometry (VLBI) enables high-angular-resolution observations in astronomy and geodesy by synthesizing a virtual telescope with baselines spanning hundreds to thousands of kilometres. Achieving high instrumental…
Context: Phase referencing is a standard calibration technique in radio interferometry, particularly suited for the detection of weak sources close to the sensitivity limits of the interferometers. However, effects from a changing…
High precision astrometric Space Very Long Baseline Interferometry (S-VLBI) at the low end of the conventional frequency range, i.e. 20cm, is a requirement for a number of high priority science goals. These are headlined by obtaining…
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100…
The balloon-borne very long baseline interferometry (VLBI) experiment is a technical feasibility study for performing radio interferometry in the stratosphere. The flight model has been developed. A balloon-borne VLBI station will be…
Cryogenic Sapphire Oscillators (CSO) developed at UWA have now been in operation around the world continuously for many years. Such oscillators, due to their excellent spectral purity are essential for interrogating atomic frequency…
Observations of ten Compact Symmetric Objects ({\rm CSO}) candidates have been made with the Very Long Baseline Array at 8.4 GHz in 2005 and with a combined Chinese and European VLBI array at 8.4 GHz in 2009. The 2009 observations…
The next-generation space VLBI mission, VSOP-2, is expected to provide unprecedented spatial resolutions at 8.4, 22, and 43GHz. In this report, phase referencing with VSOP-2 is examined in detail based on a simulation tool called ARIS. The…
The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the…
The ESO Very Large Telescope Interferometer (VLTI) is one of the leading interferometric facilities. It is equipped with several 8.2 and 1.8m telescopes, a large number of baselines up to 200m, and with several subsystems designed to enable…
Very Long Baseline Interferometry (VLBI) astrometry is a well established technique for achieving $\pm10~\mu$as parallax accuracies at frequencies well above 10~GHz. At lower frequencies, uncompensated interferometer delays associated with…
A Cryogenic Sapphire Oscillator has been implemented at 11.2 GHz using a low-vibration design pulse-tube cryocooler. Compared with a state-of-the-art liquid helium cooled CSO in the same laboratory, the square root Allan variance of their…
Very-long-baseline interferometry (VLBI) at frequencies above 230 GHz with Earth-diameter baselines gives spatial resolution finer than the ${\sim}50 \mu$as "shadow" of the supermassive black hole at the Galactic Center, Sagittarius A* (Sgr…