English
Related papers

Related papers: Rotating sample magnetometer for cryogenic tempera…

200 papers

Recent theoretical and experimental work has demonstrated how the superconducting critical temperature ($T_c$) can be modified by rotating the magnetization of a single homogeneous ferromagnet proximity-coupled to the superconducting layer.…

Superconductivity · Physics 2019-04-25 Lina G. Johnsen , Niladri Banerjee , Jacob Linder

We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of…

Mesoscale and Nanoscale Physics · Physics 2015-06-17 A. Roychowdhury , M. A. Gubrud , R. Dana , J. R. Anderson , C. J. Lobb , F. C. Wellstood , M. Dreyer

Cooling microwave resonators to near the quantum ground state, crucial for their operation in the quantum regime, is typically achieved by direct device refrigeration to a few tens of millikelvin. However, in quantum experiments that…

Quantum Physics · Physics 2020-01-29 Mingrui Xu , Xu Han , Chang-Ling Zou , Wei Fu , Yuntao Xu , Changchun Zhong , Liang Jiang , Hong X. Tang

Planar superconducting microwave resonators are key elements in a variety of technical applications and also act as sensitive probes for microwave spectroscopy of various materials of interest. Here superconducting Pb is a suitable material…

Superconductivity · Physics 2016-10-11 Nikolaj G Ebensperger , Markus Thiemann , Martin Dressel , Marc Scheffler

State-of-the-art magnetic field measurements performed in shielded environments with carefully controlled conditions rarely reflect the realities of those applications envisioned in the introductions of peer-reviewed publications.…

Atomic Physics · Physics 2020-10-13 Kai-Mei C. Fu , Geoffrey Z. Iwata , Arne Wickenbrock , Dmitry Budker

Levitated ferromagnetic systems are expected to have significant potential in precision magnetic field sensing by leveraging mechanical isolation to minimize mechanical contact and associated noise. Here, we report the implementation of a…

Quantum Physics · Physics 2026-03-03 Ren Yichong , Wu Lielie , Broer Wijnand , Xue Fei , Huang Pu , Du JiangFeng

Room temperature properties and behavior of several types of cryogenic magnetic shielding materials are measured and reported here. Large changes in the effective relative permeability are observed when the materials are perturbed with a…

Accelerator Physics · Physics 2016-01-05 Anthony C. Crawford

Workflows have been developed in the past decade to enable atom probe tomography analysis at cryogenic temperatures. The inability to control the local deposition of the metallic precursor from the gas-injection system (GIS) at cryogenic…

Materials Science · Physics 2023-06-21 James O. Douglas , Michele Conroy , Finn Giuliani , Baptiste Gault

We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…

Applied Physics · Physics 2022-05-04 M. Rosner , D. Beck , P. Fierlinger , H. Filter , C. Klau , F. Kuchler , P. Rößner , M. Sturm , D. Wurm , Z. Sun

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We…

Instrumentation and Detectors · Physics 2022-10-17 Andrew J. Woods , Alexander. M. Donald , Rasul Gazizulin , Eddy Collin , Lucia Steinke

We present a design for a new microresonator whose geometry is optimized to maximize sub-Standard Quantum Limit (SQL) performance. The new design is predicted to have thermal noise well below the SQL across a broad range of frequencies when…

We performed two-dimensional simulated tempering (ST) simulations of the two-dimensional Ising model with different lattice sizes in order to investigate the two-dimensional ST's applicability to dealing with phase transitions and to study…

Statistical Mechanics · Physics 2015-06-05 Tetsuro Nagai , Yuko Okamoto

Fast feedback from cryogenic electrical characterization measurements is key for the development of scalable quantum computing technology. At room temperature, high-throughput device testing is accomplished with a probe-based solution,…

We present a vector network analyzer (VNA) based broadband cryogenic ferromagnetic resonance (FMR) spectrometer, operating up to 20 GHz over a temperature range of 11 to 350 K. A cost effective architecture is implemented through the…

Instrumentation and Detectors · Physics 2026-01-13 Anna Merin Francis , Sunil Nair

In low temperature transport measurements, there is frequently a need to protect a device at cryogenic temperatures from thermal noise originating in warmer parts of the experiment. There are also a wide range of experiments, such as high…

Other Condensed Matter · Physics 2007-05-23 Lafe Spietz , John Teufel , R. J. Schoelkopf

The design, fabrication and performance of an apparatus for the measurement of direct rf power absorption in colossal magnetoresistive (CMR) and superconducting samples are described. The system consists of a self-resonant LC tank circuit…

Superconductivity · Physics 2015-06-25 S. Sarangi , S. V. Bhat

Progress in electromagnetic induction imaging with atomic magnetometers has brought its domain to the edge of the regime useful for biomedical imaging. However, a demonstration of imaging below the required 1 Sm$^{-1}$ level is still…

Instrumentation and Detectors · Physics 2020-04-02 Cameron Deans , Luca Marmugi , Ferruccio Renzoni

We present a compact sample holder equipped with electromagnets and high frequency transmission lines; the sample holder is intended for combined x-ray magnetic circular dichroism (XMCD) and ferromagnetic resonance measurements (FMR).…

Mesoscale and Nanoscale Physics · Physics 2015-05-13 D. A. Arena , Y. Ding , E. Vescovo , S. Z. Zohar , Y. Guan , W. E. Bailey

We find unusual temperature dependence of the ferromagnetic resonance (FMR) frequency $f_{\rm R}$ for the spin-reorientation (SR) transition, in which the easy axis changes depending on temperature, observed in the Nd permanent magnet,…

Statistical Mechanics · Physics 2020-09-21 Masamichi Nishino , Seiji Miyashita

Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is…