English
Related papers

Related papers: Experimental study of THGEM detector with mini-rim

200 papers

The thick GEM (THGEM) [1] is an "expanded" GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche…

Medical Physics · Physics 2008-11-26 M. Cortesi , R. Chechik , A. Breskin , G. Guedes , V. Dangendorf , D. Vartzky , D. Bar

The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for…

Instrumentation and Detectors · Physics 2009-09-29 S. Lami , G. Latino , E. Oliveri , L. Ropelewski , N. Turini

We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences…

Instrumentation and Detectors · Physics 2018-08-01 Rui de Olivera , Marco Cortesi

Thick GEM-like (THGEM) electrodes are robust, high gain gaseous electron multipliers, economically-manufactured by standard drilling and etching of thin printed circuit board or other materials. Their operation and structure are similar to…

Instrumentation and Detectors · Physics 2008-11-26 R. Chechik , M. Cortesi , A. Breskin , D. Vartsky , D. Bar , V. Dangendorf

Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…

Instrumentation and Detectors · Physics 2008-11-26 A. Bondar , A. Buzulutskov , R. de Oliveira , L. Ropelewski , F. Sauli , L. Shekhtman

The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic…

Instrumentation and Detectors · Physics 2009-09-11 M. Cortesi , V. Peskov , G. Bartesaghi , J. Miyamoto , S. Cohen , R. Chechik , J. M. Maia , J. M. F. dos Santos , G. Gambarini , V. Dangendorf , A. Breskin

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy…

Instrumentation and Detectors · Physics 2011-07-19 T. Zerguerras , B. Genolini , V. Lepeltier , J. Peyre , J. Pouthas , P. Rosier

Sensitivities of current directional dark matter search detectors using gas time projection chambers are now constrained by target mass. A ton-scale gas TPC detector will require large charge readout areas. We present a first demonstration…

Instrumentation and Detectors · Physics 2020-11-24 A. C. Ezeribe , C. Eldridge , W. Lynch , R. R. Marcelo Gregorio , A. Scarff , N. J. C. Spooner

A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…

We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with…

Instrumentation and Detectors · Physics 2015-06-26 V. Aulchenko , A. Bondar , A. Buzulutskov , L. Shekhtman , R. Snopkov , Yu. Tikhonov

Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a…

The characteristic studies of a Single Mask~(SM) triple Gas Electron Multiplier (GEM) detector are carried out using Ar/CO$_2$ gas mixture in 70/30 volume ratio in continuous flow mode. A Fe$^{55}$ X-ray source is used for this work. The…

Instrumentation and Detectors · Physics 2022-11-30 S. Chatterjee , A. Sen , S. Das , S. Biswas

The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the…

Instrumentation and Detectors · Physics 2023-11-20 A. G. McLean , N. J. C. Spooner , T. Crane , C. Eldridge , A. C. Ezeribe , R. R. Marcelo Gregorio , A. Scarff

The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of…

Instrumentation and Detectors · Physics 2015-06-26 R. Chechik , A. Breskin , C. Shalem , D. Moermann

Gas electron multipliers (GEM) detectors are gaseous detectors widely used for tracking and imaging applications due to their good position resolution, high efficiency at high irradiation rates, among other factors. In the present work,…

Instrumentation and Detectors · Physics 2023-03-13 Vishal Kumar , Subhendu Das , Promita Roy , Purba Bhattacharyab , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkar

The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron…

THick Gas Electron Multipliers (THGEMs) are robust and high gain Micro Pattern Gaseous Detectors which are economically manufactured by standard drilling and etching of thin printed circuit boards. In this paper, we present our recent…

Instrumentation and Detectors · Physics 2022-12-20 Promita Roy , Purba Bhattacharya , Vishal Kumar , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkar

We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs…

Instrumentation and Detectors · Physics 2011-04-11 R. Chechik , A. Breskin , C. Shalem

The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…

Instrumentation and Detectors · Physics 2021-07-05 S Chatterjee , S Roy , A Sen , S Chakraborty , S Das , S K Ghosh , S K Prasad , S Raha , S Biswas

A GEM detector with an effective area of 30*30 cm2 has been constructed using an improved self-stretch technique, which enables an easy and fast GEM assembling. The design and assembling of the detector is described. Results from tests of…

Instrumentation and Detectors · Physics 2015-06-19 Wenhao You , Yi Zhou , Cheng Li , Hongfang Chen , Ming Shao , Yongjie Sun , Zebo Tang , Jianbei Liu