English
Related papers

Related papers: Commissioning of a Geant4 based treatment plan sim…

200 papers

This article proposes a methodology to model and simulate complex systems, based on IRM4MLS, a generic agent-based meta-model able to deal with multi-level systems. This methodology permits the engineering of dynamic multi-level agent-based…

Multiagent Systems · Computer Science 2013-11-21 Jean-Baptiste Soyez , Gildas Morvan , Daniel Dupont , Rochdi Merzouki

Two full rotating gantry with different nozzles (Multipurpose nozzle with MLC, Scanning Dedicated nozzle) with conventional cyclotron system is installed and under commissioning for various proton treatment options at Samsung Medical Center…

We present a detailed simulation of the performance of water Cerenkov detectors suitable for use in the Pierre Auger Observatory. Using {\sc geant4}, a flexible object-oriented simulation program, including all known physics processes, has…

Astrophysics · Physics 2010-01-15 L. A. Anchordoqui , T. P. McCauley , T. Paul , S. Reucroft , J. D. Swain , L. Taylor

We present the design and preliminary results of a prototype beam-based digital feedback system for the Interaction Point of the International Linear Collider. A custom analogue front-end processor, FPGA-based digital signal processing…

Modulated electron radiotherapy (MERT) and combined, modulated photon/electron radiotherapy (MPERT) have received increased research attention, having shown capacity for reduced low dose exposure to healthy tissue and comparable, if not…

Medical Physics · Physics 2014-10-10 Samantha A. M. Lloyd , Isabelle M. Gagne , Sergei Zavgorodni

We present an open-source code for the simulation of electron and ion transport for user-defined gas mixtures with static uniform electric and magnetic fields. The program provides microscopic interaction simulation and is interfaced with…

Computational Physics · Physics 2021-09-14 Michele Renda , Dan Andrei Ciubotaru , Calin Iulian Banu

A new Monte Carlo-Library Least Squares (MCLLS) method was developed for the neutron inelastic-scattering and thermal-capture analysis (NITA) technique in real-time online analysis systems to determine boron content in Tinkal ore samples.…

Applied Physics · Physics 2023-08-29 Onur Erbay , Iskender Atilla Reyhancan

A simulation workflow is under development to interface particle data transfer and matching of geometry between the electromagnetic (EM) cavity simulation code ACE3P and radiation code Geant4. The target is to simulate dark current (DC)…

High Energy Physics - Experiment · Physics 2023-08-22 Lixin Ge , Zenghai Li , Cho-Kuen Ng , Liling Xiao , Hiroyasu Ego , Yoshinori Enomoto , Hiroshi Iwase , Yu Morikawa , Takashi Yoshimoto

LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…

This work presents a large language model (LLM)-based agent OpenFOAMGPT tailored for OpenFOAM-centric computational fluid dynamics (CFD) simulations, leveraging two foundation models from OpenAI: the GPT-4o and a chain-of-thought…

Fluid Dynamics · Physics 2025-12-09 Sandeep Pandey , Ran Xu , Wenkang Wang , Xu Chu

Predictive simulation of vibrational spectra of complex condensed-phase and interface systems with thousands of degrees of freedom has long been a challenging task of modern condensed matter theory. In this work, fourth-generation…

Materials Science · Physics 2025-12-04 Md Omar Faruque , Dil K. Limbu , Nathan London , Mohammad R. Momeni

A set of physics models for nanodosimetry simulation is being re-engineered for use in Geant4-based simulations. This extension of Geant4 capabilities is part of a larger scale R&D project for multi-scale simulation involving adaptable,…

Computational Physics · Physics 2009-12-10 E. Gargioni , V. Grichine , M. G. Pia

A Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) is used to study radiation fields of H-1, He-4, Li-7 and C-12 beams with similar ranges (~160-180 mm) in water. Microdosimetry spectra are simulated for wall-less and walled…

Medical Physics · Physics 2014-02-10 Lucas Burigo , Igor Pshenichnov , Igor Mishustin , Marcus Bleicher

A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field…

Accelerator Physics · Physics 2013-02-06 M. Nirkko , S. Braccini , A. Ereditato , I. Kreslo , P. Scampoli , M. Weber

The program Simourg (Simulator of Usually Requested Geometries) is based on the Geant4 toolkit and created for Monte Carlo simulation of gamma-ray spectrometric nuclear detectors with a simple axial symmetric geometry, which is typical for…

Instrumentation and Detectors · Physics 2025-12-09 V. V. Kobychev

Purpose: We presented a GPU-based MC framework, ARCHER-EPID, specifically designed for EPID transit dosimetry, with improving accuracy and efficiency. Methods: A comprehensive MC framework was developed to perform full radiation transport…

Medical Physics · Physics 2025-10-29 Ning Gao , Didi Li , Na Liu , Yankui Chang , Qiang Ren , Xi Pei , Zhi Wang , Xie George Xu

In this paper, we develop an in-memory analog computing (IMAC) architecture realizing both synaptic behavior and activation functions within non-volatile memory arrays. Spin-orbit torque magnetoresistive random-access memory (SOT-MRAM)…

Hardware Architecture · Computer Science 2021-09-15 Mohammed Elbtity , Abhishek Singh , Brendan Reidy , Xiaochen Guo , Ramtin Zand

X-ray Computed Tomography (CT) is used to recover the true surfaces of fluid channels and fed to simulation tool (ANSYS) to create accurate cyber environment. The simulation tool also receives CT-assisted multiphase fluid profiles…

Fluid Dynamics · Physics 2024-08-06 Vaishali Sharma , Arpit Kumar , Snehlata Shakya , Mayank Goswami

The recent development on large multimodal models (LMMs), especially GPT-4V(ision) and Gemini, has been quickly expanding the capability boundaries of multimodal models beyond traditional tasks like image captioning and visual question…

Information Retrieval · Computer Science 2024-03-14 Boyuan Zheng , Boyu Gou , Jihyung Kil , Huan Sun , Yu Su

Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinoblastoma treatment with external photon beam radiotherapy.…

Medical Physics · Physics 2018-09-25 P. A. Mayorga , L. Brualla , A. Flühs , W. Sauerwein , A. M. Lallena