Related papers: The 87-Sr optical frequency standard at PTB
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock…
We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total…
We report on the isotope shift between ${}^{88}$Sr and ${}^{87}$Sr on the ${}^1S_0 - {}^3P_0$ clock transitions. The interleaved operation of an optical lattice clock with two isotopes allows the canceling out of common perturbations, such…
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $\nu_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency…
Optical frequency comparison of the 40Ca+ clock transition \nu_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition \nu_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio \nu_{Ca} / \nu_{Sr} = 0.957 631 202 358…
The absolute frequency of the $^{87}{\rm Sr}$ lattice clock transition was evaluated with an uncertainty of $1.1\times 10^{-15}$ using a frequency link to the international atomic time (TAI). The frequency uncertainty of a hydrogen maser…
We describe the current status of the Ca optical frequency standards with laser-cooled neutral atoms realized in two different laboratories for the purpose of developing a possible future optical atomic clock. Frequency measurements…
We report on a frequency measurement of the $(3s^2)^1S_0\to(3s3p)^3P_1$ clock transition of $^{24}$Mg on a thermal atomic beam. The intercombination transition has been referenced to a portable primary Cs frequency standard with the help of…
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A…
We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…
The absolute frequency of the In$^{+}$ $5s^{2 1}S_{0}$ - $5s5p^{3}P_{0}$ clock transition at 237 nm was measured with an accuracy of 1.8 parts in $10^{13}$. Using a phase-coherent frequency chain, we compared the $^{1}S_{0}$ - $^{3}P_{0}$…
We report the direct frequency measurement of the visible 5s$^2$ $^1$S$_0$-5s 5p$^3$P$_1$ intercombination line of strontium that is considered a possible candidate for a future optical frequency standard. The frequency of a…
By varying the density of an ultracold $^{88}$Sr sample from $10^9$ cm$^{-3}$ to $> 10^{12}$ cm$^{-3}$, we make the first definitive measurement of the density-related frequency shift and linewidth broadening of the $^1S_0$ - $^3P_1$…
We measured the absolute frequency of the optical clock transition 1S0 (F = 1/2) - 3P0 (F = 1/2) of 171Yb atoms confined in a one-dimensional optical lattice and it was determined to be 518 295 836 590 863.5(8.1) Hz. The frequency was…
The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We…
We report on a $^{88}$Sr$^{+}$ single-ion optical clock with an estimated fractional systematic uncertainty of $7.9\times 10^{-19}$. The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation…
The $^1\mathrm{S}_0$-$^3\mathrm{P}_0$ clock transition frequency $\nu_\text{Sr}$ in neutral $^{87}$Sr has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years.…
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a…
We demonstrate a one-dimensional optical lattice clock with a spin-polarized fermionic isotope designed to realize a collision-shift-free atomic clock with neutral atom ensembles. To reduce systematic uncertainties, we developed both Zeeman…
We report on the spectroscopy of the $5s^2 {}^1S_0 (F=9/2) \to 5s5p {}^3P_0 (F=9/2)$ clock transition of ${}^{87}{\rm Sr}$ atoms (natural linewidth of 1 mHz) trapped in a one-dimensional optical lattice. Recoilless transitions with a…