English
Related papers

Related papers: A 1.82 m^2 ring laser gyroscope for nano-rotationa…

200 papers

The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…

Optics · Physics 2021-01-22 Benjamin Merkel , Daniel Repp , Andreas Reiserer

Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of…

Instrumentation and Detectors · Physics 2021-09-22 L. McCuller , S. E. Dwyer , A. C. Green , Haocun Yu , L. Barsotti , C. D. Blair , D. D. Brown , A. Effler , M. Evans , A. Fernandez-Galiana , P. Fritschel , V. V. Frolov , N. Kijbunchoo , G. L. Mansell , F. Matichard , N. Mavalvala , D. E. McClelland , T. McRae , A. Mullavey , D. Sigg , B. J. J. Slagmolen , M. Tse , T. Vo , R. L. Ward , C. Whittle , R. Abbott , C. Adams , R. X. Adhikari , A. Ananyeva , S. Appert , K. Arai , J. S. Areeda , Y. Asali , 0 S. M. Aston , C. Austin , A. M. Baer , M. Ball , S. W. Ballmer , S. Banagiri , D. Barker , J. Bartlett , B. K. Berger , J. Betzwieser , D. Bhattacharjee , G. Billingsley , S. Biscans , R. M. Blair , N. Bode , P. Booker , R. Bork , A. Bramley , A. F. Brooks , A. Buikema , C. Cahillane , K. C. Cannon , X. Chen , 0 A. A. Ciobanu , F. Clara , C. M. Compton , S. J. Cooper , K. R. Corley , 0 S. T. Countryman , 0 P. B. Covas , D. C. Coyne , L. E. H. Datrier , D. Davis , C. Di Fronzo , K. L. Dooley , J. C. Driggers , T. Etzel , T. M. Evans , J. Feicht , P. Fulda , M. Fyffe , J. A. Giaime , K. D. Giardina , P. Godwin , E. Goetz , S. Gras , C. Gray , R. Gray , E. K. Gustafson , R. Gustafson , J. Hanks , J. Hanson , T. Hardwick , R. K. Hasskew , M. C. Heintze , A. F. Helmling-Cornell , N. A. Holland , J. D. Jones , S. Kandhasamy , S. Karki , M. Kasprzack , K. Kawabe , P. J. King , J. S. Kissel , Rahul Kumar , M. Landry , B. B. Lane , B. Lantz , M. Laxen , Y. K. Lecoeuche , J. Leviton , J. Liu , M. Lormand , A. P. Lundgren , 0 R. Macas , M. MacInnis , D. M. Macleod , S. Marka , 0 Z. Marka , 0 D. V. Martynov , K. Mason , T. J. Massinger , R. McCarthy , S. McCormick , J. McIver , G. Mendell , K. Merfeld , E. L. Merilh , F. Meylahn , T. Mistry , R. Mittleman , G. Moreno , C. M. Mow-Lowry , S. Mozzon , 0 T. J. N. Nelson , P. Nguyen , L. K. Nuttall , 0 J. Oberling , Richard J. Oram , C. Osthelder , D. J. Ottaway , H. Overmier , J. R. Palamos , W. Parker , E. Payne , A. Pele , R. Penhorwood , C. J. Perez , M. Pirello , H. Radkins , K. E. Ramirez , J. W. Richardson , K. Riles , N. A. Robertson , J. G. Rollins , C. L. Romel , J. H. Romie , M. P. Ross , K. Ryan , T. Sadecki , E. J. Sanchez , L. E. Sanchez , T. R. Saravanan , R. L. Savage , D. Schaetzl , R. Schnabel , R. M. S. Schofield , E. Schwartz , D. Sellers , T. Shaffer , J. R. Smith , S. Soni , B. Sorazu , A. P. Spencer , K. A. Strain , L. Sun , M. J. Szczepanczyk , M. Thomas , P. Thomas , K. A. Thorne , K. Toland , C. I. Torrie , G. Traylor , A. L. Urban , G. Vajente , G. Valdes , D. C. Vander-Hyde , P. J. Veitch , K. Venkateswara , G. Venugopalan , A. D. Viets , C. Vorvick , M. Wade , J. Warner , B. Weaver , R. Weiss , B. Willke , C. C. Wipf , L. Xiao , H. Yamamoto , Hang Yu , L. Zhang , M. E. Zucker , J. Zweizig

We describe a nuclear spin gyroscope based on an alkali-metal-noble-gas co-magnetometer. An optically pumped alkali-metal vapor is used to polarize the noble gas atoms and detect their gyroscopic precession. Spin precession due to magnetic…

Atomic Physics · Physics 2007-05-23 T. W. Kornack , R. K. Ghosh , M. V. Romalis

Gyroscopes play a crucial role in many and diverse applications associated with navigation, positioning, and inertial sensing [1]. In general, most optical gyroscopes rely on the Sagnac effect -- a relativistically induced phase shift that…

The interrogation of an ultra-narrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the…

Optics · Physics 2015-05-14 Didier Guyomarc'H , Gaëtan Hagel , Cédric Zumsteg , Martina Knoop

We realize a Mach-Zehnder-type dual-atom-interferometer gyroscope with an interrogation arm of 40 cm length and the interference area up to 1.2 cm$^2$. The precise angular alignment of the large-scale separated Raman lasers is demonstrated…

The Virgo gravitational wave detector is an interferometer (ITF) with 3km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several…

General Relativity and Quantum Cosmology · Physics 2011-08-09 The Virgo Collaboration , T. Accadia , F. Acernese , P. Astone , G. Ballardin , F. Barone , M. Barsuglia , A. Basti , Th. S. Bauer , M. Bebronne , M. G. Beker , A. Belletoile , M. Bitossi , M. A. Bizouard , M. Blom , F. Bondu , L. Bonelli , R. Bonnand , V. Boschi , L. Bosi , B. Bouhou , S. Braccini , C. Bradaschia , M. Branchesi , T. Briant , A. Brillet , V. Brisson , T. Bulik , H. J. Bulten , D. Buskulic , C. Buy , G. Cagnoli , E. Calloni , B. Canuel , F. Carbognani , F. Cavalier , R. Cavalieri , G. Cella , E. Cesarini , O. Chaibi , E. Chassande-Mottin , A. Chincarini , A. Chiummo , F. Cleva , E. Coccia , P. -F. Cohadon , C. N. Colacino , J. Colas , A. Colla , M. Colombini , A. Conte , M. Coughlin , J. -P. Coulon , E. Cuoco , S. DAntonio , V. Dattilo , M. Davier , R. Day , R. De Rosa , G. Debreczeni , W. Del Pozzo , M. del Prete , L. Di Fiore , A. Di Lieto , M. Di Paolo Emilio , A. Di Virgilio , A. Dietz , M. Drago , G. Endroczi , V. Fafone , I. Ferrante , F. Fidecaro , I. Fiori , R. Flaminio , L. A. Forte , J. -D. Fournier , J. Franc , S. Frasca , F. Frasconi , M. Galimberti , L. Gammaitoni , F. Garufi , M. E. Gaspar , G. Gemme , E. Genin , A. Gennai , A. Giazotto , R. Gouaty , M. Granata , C. Greverie , G. M. Guidi , J. -F. Hayau , A. Heidmann , H. Heitmann , P. Hello , P. Jaranowski , I. Kowalska , A. Krolak , N. Leroy , N. Letendre , T. G. F. Li , N. Liguori , M. Lorenzini , V. Loriette , G. Losurdo , E. Majorana , I. Maksimovic , N. Man , M. Mantovani , F. Marchesoni , F. Marion , J. Marque , F. Martelli , A. Masserot , C. Michel , L. Milano , Y. Minenkov , M. Mohan , N. Morgado , A. Morgia , S. Mosca , B. Mours , L. Naticchioni , F. Nocera , G. Pagliaroli , L. Palladino , C. Palomba , F. Paoletti , M. Parisi , A. Pasqualetti , R. Passaquieti , D. Passuello , G. Persichetti , F. Piergiovanni , M. Pietka , L. Pinard , R. Poggiani , M. Prato , G. A. Prodi , M. Punturo , P. Puppo , D. S. Rabeling , I. Racz , P. Rapagnani , V. Re , T. Regimbau , F. Ricci , F. Robinet , A. Rocchi , L. Rolland , R. Romano , D. Rosinska , P. Ruggi , B. Sassolas , D. Sentenac , L. Sperandio , R. Sturani , B. Swinkels , M. Tacca , L. Taffarello , A. Toncelli , M. Tonelli , O. Torre , E. Tournefier , F. Travasso , G. Vajente , J. F. J. van den Brand , C. Van Den Broeck , S. van der Putten , M. Vasuth , M. Vavoulidis , G. Vedovato , D. Verkindt , F. Vetrano , A. Vicere , J. -Y. Vinet , S. Vitale , H. Vocca , R. L. Ward , M. Was , M. Yvert , A. Zadrozny , J. -P. Zendri

The spaceborne laser emission telescope is a core and critical component of the space gravitational wave detection system.Compared with ground-based telescopes, the on-orbit space environment is more complex and harsh, presenting higher…

Instrumentation and Methods for Astrophysics · Physics 2026-03-10 Long Yongtao , Mo Yan , Cao Shengyi , Cao Jiamin , Zhao Lujia , Wang Haibo , Wang Shuangbao , Tan Hao , Liu Xiaohong , Wang Dawei , Ma Donglin

We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to…

We report experimental and theoretical study of a rotating diode-pumped Nd-YAG ring laser with active beat note stabilization. Our experimental setup is described in the usual Maxwell-Bloch formalism. We analytically derive a stability…

Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes has been enhanced by adding multiple coupled optical resonators. The use of optical cavities is…

Instrumentation and Detectors · Physics 2007-05-23 D. Sigg , H. Rong , P. Fritschel , M. Zucker , R. Bork , N. Mavalvala , D. Ouimette , G. Gonzalez

We report the first direct measurements of the very small effect of forced diurnal polar motion, successfully observed on three of our large ring lasers, which now measure the instantaneous direction of Earth's rotation axis to a precision…

State-of-the-art optical oscillators based on lasers frequency stabilized to high finesse optical cavities are limited by thermal noise that causes fluctuations of the cavity length. Thermal noise represents a fundamental limit to the…

Optics · Physics 2015-03-19 T. Kessler , C. Hagemann , C. Grebing , T. Legero , U. Sterr , F. Riehle , M. J. Martin , L. Chen , J. Ye

We demonstrate phase and frequency stabilization of a diode laser at the thermal noise limit of a passive optical cavity. The system is compact and exploits a cavity design that reduces vibration sensitivity. The sub-Hz laser is…

Optics · Physics 2009-11-13 A. D. Ludlow , X. Huang* , M. Notcutt , T. Zanon , S. M. Foreman , M. M. Boyd , S. Blatt , J. Ye

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a…

The Sc galaxy NGC 6181 was observed at the 6m telescope of SAO RAS with the scanning Perot-Fabry interferometer in the H-alpha emission line and at the 1m telescope of SAO RAS in BVRI broadband filters with CCD. Subtraction of the mean…

Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this letter, we demonstrate ultra-high-vacuum compatible inertial…

Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed…

The absolute measurement of the Earth angular rotation rate with ground-based instruments becomes challenging if the 1 part in $10^9$ of precision has to be obtained. This threshold is important for fundamental physics and for geodesy, to…