English
Related papers

Related papers: Fast alignment of a complex tracking detector usin…

200 papers

Reliable data quality monitoring is a key asset in delivering collision data suitable for physics analysis in any modern large-scale High Energy Physics experiment. This paper focuses on the use of artificial neural networks for supervised…

Data Analysis, Statistics and Probability · Physics 2018-08-03 Adrian Alan Pol , Gianluca Cerminara , Cecile Germain , Maurizio Pierini , Agrima Seth

The performance of the ATLAS Inner Detector alignment has been studied using $pp$ collision data at $\sqrt{s} = 13$ TeV collected by the ATLAS experiment during Run 2 (2015 to 2018) of the Large Hadron Collider (LHC). The goal of the…

High Energy Physics - Experiment · Physics 2021-01-05 ATLAS Collaboration

The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a centre-of-mass energy of 14\,TeV and to reach the unprecedented peak instantaneous luminosity of 5\,$-$\,7.5\,x\,$10^{34}$\,cm$^{-2}$s$^{-1}$…

Instrumentation and Detectors · Physics 2020-04-22 Alessandro La Rosa

During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Instrumentation and Detectors · Physics 2015-01-21 T. Peltola

The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large…

Instrumentation and Detectors · Physics 2023-07-19 E. Shumka , A. Samalan , M. Tytgat , M. El Sawy , G. A. Alves , F. Marujo , E. A. Coelho , E. M. Da Costa , H. Nogima , A. Santoro , S. Fonseca De Souza , D. De Jesus Damiao , M. Thiel , K. Mota Amarilo , M. Barroso Ferreira Filho , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , H. Kou , Z. -A. Liu , J. Zhao , J. Song , Q. Hou , W. Diao , P. Cao , C. Avila , D. Barbosa , A. Cabrera , A. Florez , J. Fraga , J. Reyes , Y. Assran , M. A. Mahmoud , Y. Mohammed , I. Crotty , I. Laktineh , G. Grenier , M. Gouzevitch , L. Mirabito , K. Shchablo , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegar , B. Boghrati , M. Ebraimi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , G. Iaselli , G. Pugliese , F. Loddo , N. De Filippis , R. Aly , D. Ramos , W. Elmetenawee , S. Leszki , I. Margjeka , D. Paesani , L. Benussi , S. Bianco , D. Piccolo , S. Meola , S. Buontempo , F. Carnevali , L. Lista , P. Paolucci , F. Fienga , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , E. Asilar , J. Choi , T. J. Kim , S. Y. Choi , B. Hong , K. S. Lee , H. Y. Oh , J. Goh , I. Yu , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , R. L. Fernandez , M. Ramirez-Garcia , E. Vazquez , M. A. Shah , N. Zaganidis , A. Radi , H. Hoorani , S. Muhammad , A. Ahmad , I. Asghar , W. A. Khan , J. Eysermans , F. Torres Da Silva De Araujo

The muons reconstruction package for the SID/ILC detector has been extended to include the Electro-Magnetic Calorimeter. The procedure previously used to reconstruct the charged tracks, an helical fit approximation, has been replaced by a…

Instrumentation and Detectors · Physics 2007-05-23 C. Milstene , G. Fisk , A. Para

The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5$\times10^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000-4000…

Instrumentation and Detectors · Physics 2023-03-08 The Tracker Group of the CMS Collaboration

The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the $\eta$ coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC)…

Instrumentation and Detectors · Physics 2020-06-17 M. I. Pedraza-Morales

Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these…

Instrumentation and Detectors · Physics 2024-04-04 S. J. Paul , A. Peck , M. Arratia , Y. Gotra , V. Ziegler , R. De Vita , F. Bossu , M. Defurne , H. Atac , C. Ayerbe Gayoso , L. Baashen , N. A. Baltzell , L. Barion , M. Bashkanov , M. Battaglieri , I. Bedlinskiy , B. Benkel , F. Benmokhtar , A. Bianconi , L. Biondo , A. S. Biselli , M. Bondi , S. Boiarinov , K. Th. Brinkmann , W. J. Briscoe , W. K. Brooks , D. Bulumulla , V. D. Burkert , R. Capobianco , D. S. Carman , J. C. Carvajal , P. Chatagnon , V. Chesnokov , T. Chetry , G. Ciullo , P. L. Cole , G. Costantini , A. D Angelo , N. Dashyan , A. Deur , S. Diehl , C. Djalali , R. Dupre , A. El Alaoui , L. El Fassi , L. Elouadrhiri , A. Filippi , K. Gates , G. Gavalian , Y. Ghandilyan , G. P. Gilfoyle , A. A. Golubenko , G. Gosta , R. W. Gothe , K. Griffioen , M. Guidal , H. Hakobyan , M. Hattawy , F. Hauenstein , T. B. Hayward , D. Heddle , A. Hobart , M. Holtrop , Y. Ilieva , D. G. Ireland , E. L. Isupov , H. S. Jo , R. Johnston , K. Joo , D. Keller , M. Khachatryan , A. Khanal , A. Kim , W. Kim , V. Klimenko , A. Kripko , L. Lanza , M. Leali , P. Lenisa , X. Li , I. J. D. MacGregor , D. Marchand , L. Marsicano , V. Mascagna , B. McKinnon , C. McLauchlin , S. Migliorati , T. Mineeva , M. Mirazita , V. Mokeev , C. Munoz Camacho , P. Nadel-Turonski , P. Naidoo , K. Neupane , D. Nguyen , S. Niccolai , M. Nicol , G. Niculescu , M. Osipenko , P. Pandey , M. Paolone , R. Paremuzyan , N. Pilleux , O. Pogorelko , M. Pokhrel , J. Poudel , J. W. Price , Y. Prok , T. Reed , M. Ripani , J. Ritman , F. Sabatie , S. Schadmand , A. Schmidt , E. V. Shirokov , U. Shrestha , P. Simmerling , M. Spreafico , D. Sokhan , N. Sparveris , I. I. Strakovsky , S. Strauch , J. A. Tan , R. Tyson , M. Ungaro , S. Vallarino , L. Venturelli , H. Voskanyan , E. Voutier , D. P. Watts , X. Wei , R. Wishart , M. H. Wood , N. Zachariou

During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…

Instrumentation and Detectors · Physics 2020-04-22 Spencer R. Klein

The production of silicon detector modules that will instrument the CMS Inner Tracker has nowadays reached 1300 units out of the approximately 3700 needed in total, with an overall yield close to 96%. A description of the module design, the…

Instrumentation and Detectors · Physics 2009-11-10 Giacomo Sguazzoni

The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The…

The ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of MAPS, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE…

Instrumentation and Detectors · Physics 2022-09-21 Bogdan-Mihail Blidaru

The CMS muon system at the LHC is built of different detector technologies. The measurement of the background hit rates in the different muon detectors during the LHC Run-2 is of prime importance for an assessment of the longevity of the…

Instrumentation and Detectors · Physics 2020-04-22 Silvia Costantini

The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…

High Energy Physics - Experiment · Physics 2025-02-11 Clara Lasaosa

A prototype module for an International Linear Collider (ILC) detector was built, installed, and tested between 2006 and 2009 at CERN and Fermilab as part of the CALICE test beam program, in order to study the possibilities of extending…

Instrumentation and Detectors · Physics 2015-06-03 The CALICE Collaboration

In the High-Luminosity Large Hadron Collider (HL-LHC), one of the most challenging computational problems is expected to be finding and fitting charged-particle tracks during event reconstruction. The methods currently in use at the LHC are…

The powerful muon and tracker systems of the CMS detector together with dedicated reconstruction software allow precise and efficient measurement of muon tracks originating from proton-proton collisions. The standard muon reconstruction…

Instrumentation and Detectors · Physics 2008-10-22 Norbert Neumeister , Chang Liu

In preparation for the High Luminosity LHC, the entire tracker detector of the CMS experiment will be exchanged as part of the Phase-2 Upgrade. The new Outer Tracker will comprise approximately 13,000 silicon sensor modules, of which 7608…

Instrumentation and Detectors · Physics 2022-05-25 F. Zhang , G. Blanchot , S. Higginbotham , A. Honma , A. Kalogeropoulos , M. Kovacs , A. La Rosa , S. Nasr