Related papers: A GPU-based finite-size pencil beam algorithm with…

200 papers

Nanodosimetry relates Ionization Detail (ID) and ionization parameters (Ip) to biological endpoints relevant for charged-particle radiotherapy. This supports a more physics-based modeling of biological effectiveness than traditional…

In radiotherapy, a trade-off exists between computational workload/speed and dose calculation accuracy. Calculation methods like pencil-beam convolution can be much faster than Monte-Carlo methods, but less accurate. The dose difference,…

Medical Physics · Physics 2020-05-18 Yixun Xing , Ph. D. , You Zhang , Ph. D. , Dan Nguyen , Ph. D. , Mu-Han Lin , Ph. D. , Weiguo Lu , Ph. D. , Steve Jiang , Ph. D

A novel dose calculation approach was designed based on the application of LSTM network that processes the 3D patient/phantom geometry as a sequence of 2D computed tomography input slices yielding a corresponding sequence of 2D slices that…

Medical Physics · Physics 2021-06-09 Ahmad Neishabouri , Niklas Wahl , Ulrich Köthe , Mark Bangert

The emergence of artificial intelligence (AI) accelerators like NVIDIA Tensor Cores offers new opportunities to speed up tensor-heavy scientific computations. However, applying them to quantum chemistry is challenging due to strict accuracy…

Chemical Physics · Physics 2026-04-20 Hua Huang , Wenkai Shao , Jeff Hammond

Accurate dose calculation is vitally important for proton therapy. Pencil beam (PB) model-based dose calculation is fast but inaccurate due to the approximation when dealing with inhomogeneities. Monte Carlo (MC) dose calculation is the…

A broad-beam-delivery system for heavy-charged-particle radiotherapy often employs multiple collimators and a range-compensating filter, which potentially offer complex beam customization. In treatment planning, it is however difficult for…

Medical Physics · Physics 2012-01-11 Nobuyuki Kanematsu

Purpose: To demonstrate the feasibility of fast Monte Carlo (MC) based inverse biological planning for the treatment of head and neck tumors in spot-scanning proton therapy. Methods: Recently, a fast and accurate Graphics Processor Unit…

Medical Physics · Physics 2016-10-11 H. Wan Chan Tseung , J. Ma , C. R. Kreofsky , D. Ma , C. Beltran

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging…

Medical Physics · Physics 2010-04-13 Xun Jia , Yifei Lou , John Lewis , Ruijiang Li , Xuejun Gu , Chunhua Men , William Y. Song , Steve B. Jiang

A model for beam customization with collimators and a range-compensating filter based on the phase-space theory for beam transport is presented for dose distribution calculation in treatment planning of radiotherapy with protons and heavier…

Medical Physics · Physics 2008-05-27 Nobuyuki Kanematsu , Shunsuke Yonai , Azusa Ishizaki , Masami Torikoshi

Monte Carlo (MC) simulations provide gold-standard accuracy for carbon ion therapy dose calculations but are computationally intensive. Analytical pencil beam algorithms offer speed but reduced accuracy in heterogeneous tissues. We…

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…

Medical Physics · Physics 2015-05-19 Xun Jia , Bin Dong , Yifei Lou , Steve B. Jiang

This paper describes the algorithm and examines the performance of an IMRT beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated…

Medical Physics · Physics 2009-11-10 David Djajaputra , Qiuwen Wu , Yan Wu , Radhe Mohan

A new strategy for radiation therapy dosimetry planning (RTDP) used to reduce dose estimation errors due to respiratory motion in breast treatment was illustrated and evaluated in this study. On CT data set acquired for breast treatment,…

Medical Physics · Physics 2021-10-20 Mazen Moussallem , Pauline Harb , Hanane Rima , Zeina Al Kattar , Saad Ayoubi

To accurately verify the dose of intensity-modulated radiation therapy (IMRT), we have used a global optimization method to investigate a new dose-verification algorithm. In practical application of this quality assurance (QA) procedure,…

Medical Physics · Physics 2007-05-23 Dong Hyun Park , Sung-Yong Park , Dahl Park , Tae-Hyun Kim , Kyung Hwan Shin , Dae Yong Kim , Kwan-Ho Cho

Conventional radiotherapy dose calculation algorithms are often computationally slow and non-differentiable, creating bottlenecks for online adaptive radiotherapy (ART) and limiting end-to-end automatic planning. Deep learning provides…

This study presents FREDopt, a newly developed GPU-accelerated open-source optimization software for simultaneous proton dose and dose-averaged LET (LETd) optimization in IMPT treatment planning. FREDopt was implemented entirely in Python,…

Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…

Purpose: We presented a GPU-based MC framework, ARCHER-EPID, specifically designed for EPID transit dosimetry, with improving accuracy and efficiency. Methods: A comprehensive MC framework was developed to perform full radiation transport…

Medical Physics · Physics 2025-10-29 Ning Gao , Didi Li , Na Liu , Yankui Chang , Qiang Ren , Xi Pei , Zhi Wang , Xie George Xu

Purpose: To develop a DL-based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on-line adaptive proton therapy clinical decision and subsequent replanning. Methods: PBSPT plans of 103 prostate cancer…

Background: Intensity-modulated proton therapy (IMPT) using pencil beam technique scans tumor in a layer by layer, then spot by spot manner. It can provide highly conformal dose to tumor targets and spare nearby organs-at-risk (OAR). Fast…

Medical Physics · Physics 2024-11-28 Aoxiang Wang , Ya-Nan Zhu , Jufri Setianegara , Yuting Lin , Peng Xiao , Qingguo Xie , Hao Gao