Related papers: Stable double-resonance optical spring in laser gr…
The uncertainty principle, applied naively to the test masses of a laser-interferometer gravitational-wave detector, produces a Standard Quantum Limit (SQL) on the interferometer's sensitivity. It has long been thought that beating this SQL…
Rubidium two-photon frequency standards are emerging as powerful contenders for compact, durable devices with exceptional stability. The field has focused on single-color excitation to date. Here we demonstrate the key advantages of a…
We demonstrate a new technique for the experimental measurement of the spectral coherence of microresonator optical frequency combs. Specifically, we use a spectral interference method, typically used in the context of supercontinuum…
We consider various approaches to the creation of a high-stability active optical frequency standard, where the atomic ensemble itself produces a highly stable and accurate frequency signal. The short-time frequency stability of such…
A stable optical resonator has been built using a 30 micrometer-wide, metal-coated microcantilever as one mirror. The second mirror was a 12.7 mm-diameter concave dielectric mirror. By positioning the two mirrors 75 mm apart in a…
We consider a uniform dipolar Fermi gas in two-dimensions (2D) where the dipole moments of fermions are aligned by an orientable external field. We obtain the ground state of the gas in Hartree-Fock approximation and investigate RPA…
Optical sound pressure measurement is a promising technology to establish primary acoustic standards without reliance on specific types of microphones. We developed a precision optical sound pressure measurement system by combining a…
We study the dynamics and stability of soliton optical frequency comb generation in a dissipative, coherently pumped cavity with both second and third-order nonlinearity. Cavity sweep simulations and linear stability analysis based on path…
In this work we investigate an optomechanical system consisting of two cavities coupled to the same mechanical resonator. We consider each cavity being weakly pumped as well as a small tunneling rate between the cavities. In such…
We simulate the performance of a gravitational wave interferometer in the Dual Recycling (DR) configuration, as will be used for systems like Advanced-LIGO. Our grid-based simulation program models complex interferometric detectors with…
Using the force-susceptibility formalism of linear quantum measurements, we study the dynamics of signal recycled interferometers, such as LIGO-II. We show that, although the antisymmetric mode of motion of the four arm-cavity mirrors is…
It has long been thought that the sensitivity of laser interferometric gravitational-wave detectors is limited by the free-mass standard quantum limit, unless radical redesigns of the interferometers or modifications of their input/output…
The capability of optical resonators to extend the effective radiation-matter interaction length originates from a multipass effect, hence is intrinsically limited by the resonator quality factor. Here, we show that this constraint can be…
The dominant hurdle to the operation of optomechanical systems in the quantum regime is the coupling of the vibrating element to a thermal reservoir via mechanical supports. Here we propose a scheme that uses an optical spring to replace…
We propose a scheme for the generation of a robust stationary squeezed state of a mechanical resonator in a quadratically coupled optomechanical system, driven by a pulsed laser. The intracavity photon number presents periodic intense peaks…
We present a novel locking scheme for active length-stabilization and frequency detuning of a cavity optomechanical device based on the optical spring effect. The scheme can be used as an alternative to the Pound-Drever-Hall locking…
We demonstrated for the first time the characterization of absolute frequency stability of three reference cavities by cross beating three laser beams which are independently locked to these reference cavities. This method shows the…
The combination of low mass density, high frequency, and high quality-factor of mechanical resonators made of two-dimensional crystals such as graphene make them attractive for applications in force sensing/mass sensing, and exploring the…
We report on the realization of an optical microcavity consisting in the plane-plane arrangement of two suspended resonant mirrors possessing spectrally overlapping high-quality factor internal resonances. We first investigate its generic…
For the optical generation of ultrastable microwave signals for fountain clocks we developed a setup, which is based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a…