Related papers: A new approach to the front-end readout of cryogen…
This article presents the readout electronics of a novel beam monitoring system for ion research facility accelerator. The readout electronics are divided into Front-end Card (FEC) and Readout Control Unit (RCU). FEC uses Topmetal II minus…
The detector readout architecture introduced in this paper is intended for small to medium size physics experiments that have moderate bandwidth needs, and applications that require an ultimately low background radioactivity for the parts…
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to…
Micromegas detector is a gas detector with parallel plate structure, and it consists of a conversion gap in which radiations liberate ionization electrons and a thin amplification gap. The signal of the micromegas detector consists of two…
The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…
We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by…
In the pursuit of quantum computing, solid-state quantum systems, particularly superconducting ones, have made remarkable advancements over the past two decades. However, achieving fault-tolerant quantum computing for next-generation…
We report on the solution optimized for characterizing SNSPDs by rejecting electromagnetic interference from various sources. The proposed readout method enhances measurement stability and enables reliable device characterization at low…
The present thesis follows a three years' work in design, realization and operation of electronic circuits for the readout of particle and radiation sensors, carried out in close collaboration with the Istituto Nazionale di Fisica Nucleare…
Scaling of multi-pixel cryogenic detectors for imaging becomes increasingly difficult with size due to complexity of readout circuitry and cryogenic constraints (thermal load from wiring). We propose and demonstrate a new readout scheme…
All first-generation large-scale gravitational wave detectors are operated at the dark fringe and use a heterodyne readout employing radio frequency (RF) modulation-demodulation techniques. However, the experience in the currently running…
A new approach was developed for the design of front-end circuits for semiconductor radiation detectors. The readout scheme consists of a first stage made of only a few components located close to the detector, and of a remote second stage…
In the strive for scalable quantum processors, significant effort is being devoted to the development of cryogenic classical hardware for the control and readout of a growing number of qubits. Here we report on a cryogenic circuit…
We have developed a cryogenic platform for the control and readout of spin qubits that comprises a high density of dc and radio frequency sample interconnects based on a set of coupled printed circuit boards. The modular setup incorporates…
Cryogenic detectors are at the forefront of rare-event search experiments, including direct detection of dark matter, coherent elastic neutrino-nucleus scattering, neutrinoless double-beta decay, and searches for fractionally charged…
Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit…
The STEREO experiment will search for a sterile neutrino by measuring the anti-neutrino energy spectrum as a function of the distance from the source, the ILL nuclear reactor. A dedicated electronic system, hosted in a single microTCA…
Cryogenic opto-electronic interconnects are gaining increasing interest as a means to control and read out cryogenic electronic components. The challenge is to achieve sufficient signal integrity with low heat load processing. In this…
The ion-sensitive field-effect transistor (ISFET) is an emerging technology that has received much attention in numerous research areas, including biochemistry, medicine, and security applications. However, compared to other types of…
Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias…