English
Related papers

Related papers: Micromegas for imaging hadronic calorimetry

200 papers

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and…

Instrumentation and Detectors · Physics 2022-04-04 Timothy Andeen , Julia Gonski , James Hirschauer , James Hoff , Gabriel Matos , John Parsons

The search for weakly interacting, light particles that couple to photons received significant attention in recent years. When those particles are produced at high energies, they lead to two, nearly collinear photons after their decay and…

Instrumentation and Detectors · Physics 2022-10-05 Friedemann Neuhaus , Elisa Ruiz Choliz , Matthias Schott

Five small prototype micromegas detectors were positioned in the ATLAS detector during Large Hadron Collider running at $\sqrt{s} = 7$ and $8\, \mathrm{TeV}$. A $9\times 4.5\, \mathrm{cm^2}$ double drift gap detector was placed in front of…

Instrumentation and Detectors · Physics 2015-06-17 Y. Kataoka , S. Leontsinis , K. Ntekas

An imaging calorimeter has been designed and is being built for the PAMELA satellite-borne experiment. The physics goals of the experiment are the measurement of the flux of antiprotons, positrons and light isotopes in the cosmic radiation.…

Instrumentation and Detectors · Physics 2015-06-26 M. Boezio , V. Bonvicini , E. Mocchiutti , P. Schiavon , G. Scian , A. Vacchi , G. Zampa , N. Zampa

An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas…

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses small…

Instrumentation and Detectors · Physics 2019-08-13 Katja Seidel

The DHCAL collaboration is assembling a large scale prototype Digital Hadron Calorimeter (DHCAL). The calorimeter utilizes Resistive Plate Chambers (RPCs) as active medium and features of the order of 400,000 1 \times 1 cm2 pads with binary…

Instrumentation and Detectors · Physics 2010-05-05 Jose Repond

The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…

Instrumentation and Detectors · Physics 2025-11-24 The CMS Electromagnetic Calorimeter Group

The bulk Micromegas detector is considered to be a promising candidate for building TPCs for several future experiments including the projected linear collider. The standard bulk with a spacing of 128 micron has already established itself…

Instrumentation and Detectors · Physics 2016-05-11 Purba Bhattacharya , Sudeb Bhattacharya , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar , Paul Colas , David Attie

This paper describes an R&D electronic program for the next generation of linear collider electromagnetic calorimeter. After a brief presentation of the requirements, a global scheme of the electronics is given. Then, we describe the three…

Instrumentation and Detectors · Physics 2007-05-23 S. Manen , G. Bohner , J. Lecoq , J. Fleury , C. De la Taille , G. Martin , the FLC Collaboration

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…

Instrumentation and Detectors · Physics 2012-08-08 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , Y. Mikami , N. K. Watson T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward W. Yan , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , C. Günter , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , I. Marchesini , N. Meyer , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , J. Haller , S. Richter , J. Samson P. Eckert , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , S. Uozumi , J. A. Ballin , P. D. Dauncey , A. -M. Magnan , H. S. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , Y. Soloviev , V. Kozlov , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , A. Frey , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , G. Guilhem , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , M. Nishiyama , T. Takeshita , S. Tozuka , T. Buanes , G. Eigen

A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout…

Instrumentation and Detectors · Physics 2015-06-19 Y. Haddad , M. Ruan , V. Boudry

Muon imaging technology is an innovative imaging technique that can be applied in volcano imaging, heavy nuclear material detection, and archaeological research. The Micromegas detector is a promising choice for muon imaging due to its high…

Instrumentation and Detectors · Physics 2024-10-28 Ting Wang , Yu Wang , Zhihang Yao , Yulin Liu , Changqing Feng , Zhiyong Zhang , Shubin Liu

In particle physics, homogeneous calorimeters are used to measure the energy of particles as they interact with the detector material. Although not as precise as trackers or muon detectors, these calorimeters provide valuable insights into…

The CALICE Semi-digital hadronic calorimeter built in 2011, was installed and tested during two periods of two weeks each in 2012 at CERN SPS facilities. The detector has more than 450000 channels with a semi-digital readout distributed on…

Instrumentation and Detectors · Physics 2019-08-16 Y. Haddad

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses small…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time…

The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…

We present results of the performance of the second prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, as well as…

The development of cryogenic calorimeters was originally motivated by the fact that very low energy thresholds and excellent energy resolutions can be achieved by these devices. Cryogenic devices are widely used in double beta decay…

High Energy Physics - Experiment · Physics 2011-01-17 Klaus Pretzl