English
Related papers

Related papers: Further developments and tests of microstrip gas c…

200 papers

We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges…

Instrumentation and Detectors · Physics 2011-07-28 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors…

Instrumentation and Detectors · Physics 2011-08-31 P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , P. Pietropaolo , P. Picchi

We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and…

Instrumentation and Detectors · Physics 2015-05-18 P. Fonte , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard

In the last few years our group have focused on developing various designs of spark-protected micropattern gaseous detectors featuring resistive electrodes instead of the traditional metallic ones: resistive microstrip counters, resistive…

Instrumentation and Detectors · Physics 2015-06-04 P. Fonte , E. Nappi , P. Martinengo , R. Oliveira , V. Peskov F. Pietropaolo , P. Picchi

The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber (RMSGC) using additional field shaping strips located inside the detector substrate are described.

Instrumentation and Detectors · Physics 2014-04-01 R. Oliveira , S. Franchino , V. Peskov

We have developed prototypes of GEM-like detectors with resistive electrodes to be used as RICH photodetectors equipped with CsI photocathodes. The main advantages of these detectors are their intrinsic spark protection and possibility to…

Instrumentation and Detectors · Physics 2008-11-26 A. G. Agocs , A. Di Mauro , A. Ben David , B. Clark , P. Martinengo , E. Nappi , V. Peskov

The development of gaseous detectors has been exciting again since the appearance of a MicroStrip Gas Chamber(MSGC) in 1988, which is made using a micro-electronics technology. These days lots of variations of the advanced gaseous detectors…

High Energy Physics - Experiment · Physics 2009-10-31 Toru Tanimori , Yuji Nishi , Atsuhiko Ochi , Yasuro Nishi

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

Instrumentation and Detectors · Physics 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

We have developed and tested several new designs of GEM detectors with micropattern electrodes manufactured by microelectronic technology. In one design, the inner layer of the detector electrode consists of thin metallic strips and the…

Instrumentation and Detectors · Physics 2009-06-25 A. Di Mauro , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our…

Instrumentation and Detectors · Physics 2008-07-18 V. Peskov , P. Martinengo , E. Nappi , R. Oliveira , G. Paic , F. Pietropaolo , P. Picchi

In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photocathodes. The hole type structure considerably suppresses the…

Instrumentation and Detectors · Physics 2008-11-26 J. M. Bidault , P. Fonte , T. Francke , P. Galy , V. Peskov , I. Rodionov

MicroPattern Gaseous Detectors (MPGD) made of resistive strips have raised as a promising technology for the protection against spark processes having place in the gaseous chamber. The reproduction of the signals and its propagation through…

Instrumentation and Detectors · Physics 2015-06-03 J. Galan

A new anode support structure for the spherical proportional counter is presented that incorporates a resistive correction electrode made of glass. This electrode improves the electric field homogeneity versus angle while suppressing the…

Instrumentation and Detectors · Physics 2018-12-05 I. Katsioulas , I. Giomataris , P. Knights , M. Gros , X. F. Navick , K. Nikolopoulos , I. Savvidis

Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim…

Instrumentation and Detectors · Physics 2012-04-11 V. Peskov

We report promising initial results obtained with new resistive-electrode GEM (RETGEM) detectors manufactured, for the first time, using screen printing technology. These new detectors allow one to reach gas gains nearly as high as with…

Instrumentation and Detectors · Physics 2009-12-10 B. Clark , A. G. Agocs , R. Oliveira , V. Peskov , Pietropaolo , Picchi

In this work we present a novel idea for a compact spark-protected single amplification stage Micro-Pattern Gas Detector (MPGD). The detector amplification stage, realized with a structure very similar to a GEM foil, is embedded through a…

Instrumentation and Detectors · Physics 2015-06-23 G. Bencivenni , R. De Oliveira , G. Morello , M. Poli Lener

Micromegas is presently in use by many experiments providing enhanced performance when used in high particle environment. Compared with other solid-state detectors or conventional gas counters Micromegas is robust and radiation hard. Recent…

Instrumentation and Detectors · Physics 2008-11-26 I. Giomataris

We describe the first tests with a new proportional gas detector. Its geometry consists in slits opened in a copper metallized kapton foil with 30 micron anode strips suspended in these openings. In this way the multiplication process is…

Instrumentation and Detectors · Physics 2007-05-23 J. Claude Labbe , F. Gomez , T. Nunez , A. Pazos , P. Vazquez

We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…

Instrumentation and Detectors · Physics 2017-10-11 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi