English
Related papers

Related papers: A lens-coupled scintillation counter in cryogenic …

200 papers

Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with…

Instrumentation and Detectors · Physics 2015-01-27 M. Sorel

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

The advent of the silicon photomultiplier has allowed the development of highly segmented calorimeters using plastic scintillator as the active media, with photodetectors embedded in the calorimeter, in dimples in the plastic. To reduce the…

Instrumentation and Detectors · Physics 2024-01-23 B. Kronheim , A. Belloni , T. K. Edberg , S. C. Eno , C. Howe , C. Palmer , C. Papageorgakis , M. Paranjpe , S. Sriram

We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…

At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…

Instrumentation and Detectors · Physics 2023-03-01 Yuanjing Ji , Zebo Tang , Chen Li , Xin Li , Ming Shao

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke…

A scintillation muon telescope module with fiber-optic light collection using silicon photomultipliers was developed, tested, and installed for continuous monitoring to study cosmic ray variations. The aim of this study was to create a…

Instrumentation and Methods for Astrophysics · Physics 2026-02-10 Belov S. M. , Yanke V. G

The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…

We are developing a novel high-brightness atomic beam, comprised of a two-body exotic atom called muonium (M $ = \mu^+ + e^-$), for next-generation atomic physics and gravitational interaction measurements. This M source originates from a…

Instrumentation and Detectors · Physics 2022-06-29 J. Zhang , D. Goeldi , R. Iwai , M. Sakurai , A. Soter

We present the design and measured performance of a light emitting diode (LED) module for spatially mapping kinetic inductance detector (KID) arrays in the laboratory. Our novel approach uses a multiplexing scheme that only requires seven…

Instrumentation and Methods for Astrophysics · Physics 2023-01-13 Jordan E. Shroyer , Matt Nelson , Liam Walters , Bradley R. Johnson

We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the…

Mesoscale and Nanoscale Physics · Physics 2015-01-19 A. J. R. MacDonald , G. G. Popowich , B. D. Hauer , P. H. Kim , A. Fredrick , X. Rojas , P. Doolin , J. P. Davis

Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light…

Instrumentation and Detectors · Physics 2019-05-22 M. Ehlert , A. Hollnagel , I. Korol , A. Korzenev , H. Lacker , P. Mermod , J. Schliwinski , L. Shihora , P. Venkova , M. Wurm

A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…

Instrumentation and Detectors · Physics 2018-06-27 B. D. Leverington , M. Dziewiecki , L. Renner , R. Runze

We measure the liquid argon scintillation response to electronic recoils in the energy range of $2.82$ to $1274.6~{\rm keV}$ at null electric field. The single-phase detector with a large optical coverage used in this measurement yields…

Instrumentation and Detectors · Physics 2020-11-25 M. Kimura , K. Aoyama , M. Tanaka , K. Yorita

We have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects…

Instrumentation and Detectors · Physics 2023-06-14 M. Chaudhuri , G. Agnolet , V. Iyer , V. K. S. Kashyap , M. Lee , R. Mahapatra , S. Maludze , N. Mirabolfathi , B. Mohanty , M. Platt , A. Upadhyay , S. Sahoo , S. Verma

The NUCLEUS experiment aims at measuring the coherent elastic scattering of nuclear reactor antineutrinos off nuclei using cryogenic calorimeters. Operating at an overburden of 3m.w.e., muon-induced backgrounds are expected to be dominant.…

Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI…

Instrumentation and Detectors · Physics 2015-09-02 B. Lopez Paredes , C. D. R. Azevedo , S. Paganis , A. L. M. Silva , N. J. C. Spooner , J. F. C. A. Veloso

There is a global trend to increase the light yield of CsI scintillators used in neutrino and dark matter detection by operating undoped crystals at cryogenic temperatures. However, high light yield alone is not sufficient to guarantee a…

Instrumentation and Detectors · Physics 2023-07-25 K. Ding , J. Liu , Y. Yang , K. Scholberg , D. M. Markoff

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities.…

Instrumentation and Detectors · Physics 2021-03-24 B. Aimard , L. Aizawa , C. Alt , J. Asaadi , M. Auger , V. Aushev , D. Autiero , A. Balaceanu , G. Balik , L. Balleyguier , E. Bechetoille , D. Belver , A. M. Blebea-Apostu , S. Bolognesi , S. Bordoni , N. Bourgeois , B. Bourguille , J. Bremer , G. Brown , G. Brunetti , L. Brunetti , D. Caiulo , M. Calin , E. Calvo , M. Campanelli , K. Cankocak , C. Cantini , B. Carlus , B. M. Cautisanu , M. Chalifour , A. Chappuis , N. Charitonidis , A. Chatterjee , A. Chiriacescuf , P. Chiu , S. Conforti , P. Cotte , P. Crivelli , C. Cuesta , J. Dawson , I. De Bonis , C. De La Taille , A. Delbart , S. Di Luise , F. Doizon , C. Drancourt , D. Duchesneau , F. Dulucq , F. Duval , S. Emery , A. Ereditato , A. Falcone , K. Fusshoeller , A. Gallego-Ros , V. Galymov , N. Geffroy , A. Gendotti , A. Gherghel-Lascu , I. Gil-Botella , C. Girerd , M. C. Gomoiu , P. Gorodetzky , E. Hamada , R. Hanni , T. Hasegawa , A. Holin , S. Horikawa , M. Ikeno , S. Jiménez , A. Jipa , M. Karolak , Y. Karyotakis , S. Kasai , K. Kasami , T. Kishishita , H. Konari , I. Kreslo , D. Kryn , P. Kunzé , M. Kurokawa , Y. Kuromori , C. Lastoria , I. Lazanu , G. Lehmann-Miotto , M. Leyton , N. Lira , K. Loo , D. Lorca , P. Lutz , T. Lux , J. Maalampi , G. Maire , M. Maki , L. Manenti , R. M. Margineanu , J. Marteau , G. Martin-Chassard , H. Mathez , E. Mazzucato , G. Misitano , D. Mladenov , L. Molina Bueno , T. S. Mosu , W. Mu , S. Murphy , K. Nakayoshi , S. Narita , D. Navas-Nicolás , K. Negishi , M. Nessi , M. Niculescu-Oglinzanu , F. Noto , A. Noury , Y. Onishchuk , C. Palomares , M. Parvu , T. Patzak , Y. Penichot , E. Pennacchio , L. Periale , H. Pessard , F. Pietropaolo , D. Pugnere , B. Radics , D. Redondo , C. Regenfus , A. Remoto , F. Resnati , O. Ristea , A. Rubbia , A. Saftoiu , K. Sakashita , F. Sanchez , C. Santos , A. Scarpelli , C. Schloesser , K. Sendai , F. Sergiampietri , S. Shahsavarani , M. Shoji , J. Sinclair , J. Soto-Oton , D. I. Stanca , D. Stefan , R. Sulej , M. Tanaka , V. Toboaru , A. Tonazzo , W. Tromeur , W. H. Trzaska , T. Uchida , L. Urda , F. Vannucci , G. Vasseur , A. Verdugo , T. Viant , S. Vihonen , S. Vilalte , M. Weber , S. Wu , J. Yu , L. Zambelli , M. Zito

A number of critical active and passive components of optical links have been tested at 77 K or lower temperatures, demonstrating potential development of optical links operating inside the liquid argon time projection chamber (LArTPC)…

‹ Prev 1 4 5 6 7 8 10 Next ›