In this work we attempt to establish the best time resolution attainable with a scintillation counter consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode. The measured time resolution is inversely…
We present a cryogenic setup where an optical Fabry-Perot resonator is coupled to a single-mode optical fiber with coupling efficiency above 90% at mK temperatures without realignment during cooling down. The setup is prealigned at room…
A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…
Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and…
Simulations of photon propagation in scintillation detectors were performed with the aim to find the optimal scintillator geometry, surface treatment, and shape of external reflector in order to achieve maximum light collection efficiency…
Future cryogenic experiments searching for rare events require reliable, efficient and robust techniques for the detection of photons at temperatures well below that to which low-temperature photomultipliers (PMT) were characterised.…
Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design…
We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…
The scintillating properties of active materials used in high energy and particle physics experiments play an important role regarding the performances of both calorimeters and experiments. Two scintillator materials, a scintillating glass…
The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were…
The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…
The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…
We have developed a sensor system based on an optical photon-counting imager with high timing resolution, aiming for highly time-variable astronomical phenomena. The detector is a monolithic Geiger-mode avalanche photodiode array customized…
We report demonstration of light detection in liquid argon using an acrylic lightguide detector system. This opens the opportunity for development of an inexpensive, large-area light collection system for large liquid argon time projection…
New scintillation counters have been designed and constructed for the CDF upgrade in order to complete the muon coverage of the central CDF detector, and to extend this coverage to larger pseudorapidity. A novel light collection technique…
CryoCsI, the proposed prototype, is a cryogenic undoped CsI scintillating detector, which has a much lower energy threshold potentially down to 0.5 keV$_{nr}$ compared to the doped CsI. This enhanced sensitivity of CryoCsI allows for the…
The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to…
A methodology to measure Near Infrared (NIR) scintillations in gaseous and liquid Ar, using Geiger-mode APDs (GAPDs) sensitive in the NIR and pulsed X-ray irradiation, is described. This study has been triggered by the development of…
The application of reach-through avalanche photodiodes (R'APD) as a photodetector for scintillator tiles has been investigated. The light collected by WLS fibers (0.84mm and 1mm diameter) embedded in the scintillator has been transmited to…
Detectors for direct dark matter search using noble gases in liquid phase as detection medium need to be coupled to liquefaction, purification and recirculation systems. A dedicated cryogenic system has been assembled and operated at the…