Related papers: Planck Early Results. V. The Low Frequency Instrum…
Removal of systematic effects is crucial in present and future CMB experiments mapping large fraction of the sky. Accurate CMB measurements ask for multi-feed array instruments observing the sky with a redundant scanning strategy covering…
Measurements of the cosmic microwave background (CMB) allow high precision observation of the cosmic plasma at redshift z~1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy,…
The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was designed and built incorporating state of the art…
We present a new map-making method for CMB measurements. The method is based on the destriping technique, but it also utilizes information about the noise spectrum. The low-frequency component of the instrument noise stream is modelled as a…
We present foreground-reduced CMB maps derived from the full Planck data set in both temperature and polarization. Compared to the corresponding Planck 2013 temperature sky maps, the total data volume is larger by a factor of 3.2 for…
We present a harmonic model for the data analysis of an all-sky cosmic microwave background survey, such as Planck, where the survey is obtained through ring-scans of the sky. In this model, resampling and pixelisation of the data are…
Observations of cosmic microwave background polarisation, essential for probing a potential phase of inflation in the early universe, suffer from contamination by polarised emission from the Galactic interstellar medium. This work combines…
We estimate the effects of low temporal frequency modes in the time stream on sky maps such as expected from the PLANCK experiment -- a satellite mission designed to image the sky in the microwave band. We perform the computations in a…
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered…
We present here the basic issues of our simulations of PLANCK/LFI observations focussing on the study of the stripes generated by the 1/f noise, including realistic estimates of the 1/f knee frequency, based on the Seiffert et al. (1997)…
The High Frequency Instrument (HFI) of Planck is the most sensitive CMB experiment ever planned. Statistical fluctuations (photon noise) of the CMB itself will be the major limitation to the sensitivity of the CMB channels. Higher frequency…
Planck has mapped the microwave sky in nine frequency bands between 30 and 857 GHz in temperature and seven bands between 30 and 353 GHz in polarization. In this paper we consider the problem of diffuse astrophysical component separation,…
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific…
Context: The Planck data releases have provided the community with sub-millimetre and radio observations of the full-sky at unprecedented resolutions. We make use of the Planck 353, 545 and 857 GHz maps alongside the IRAS 3000 GHz map.…
In this paper we present an overview of the Telescope designed for ESA's mission dedicated to map the Cosmic Microwave Background Anisotropies and Polarization. Two instruments, LFI and HFI, operate in an overall frequency range between 25…
The Planck design and scanning strategy provide many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70GHz and 100GHz channels. Based on different…
We present the intensity foreground algorithms and model employed within the BeyondPlanck analysis framework. The BeyondPlanck analysis is aimed at integrating component separation and instrumental parameter sampling within a global…
Purpose: Low-field MRI systems operate at single MHz-range frequencies, where signal losses are primarily dominated by thermal noise from the radio-frequency (RF) receive coils. Achieving operation close to this limit is essential for…
Aims. To investigate the performance of a deconvolution map-making algorithm for an experiment with a circular scanning strategy, specifically in this case for the analysis of Planck data, and to quantify the effects of making maps using…
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed…