English
Related papers

Related papers: Study of gas purifiers for the CMS RPC detector

200 papers

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…

Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas…

The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large…

Instrumentation and Detectors · Physics 2023-07-19 E. Shumka , A. Samalan , M. Tytgat , M. El Sawy , G. A. Alves , F. Marujo , E. A. Coelho , E. M. Da Costa , H. Nogima , A. Santoro , S. Fonseca De Souza , D. De Jesus Damiao , M. Thiel , K. Mota Amarilo , M. Barroso Ferreira Filho , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , H. Kou , Z. -A. Liu , J. Zhao , J. Song , Q. Hou , W. Diao , P. Cao , C. Avila , D. Barbosa , A. Cabrera , A. Florez , J. Fraga , J. Reyes , Y. Assran , M. A. Mahmoud , Y. Mohammed , I. Crotty , I. Laktineh , G. Grenier , M. Gouzevitch , L. Mirabito , K. Shchablo , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegar , B. Boghrati , M. Ebraimi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , G. Iaselli , G. Pugliese , F. Loddo , N. De Filippis , R. Aly , D. Ramos , W. Elmetenawee , S. Leszki , I. Margjeka , D. Paesani , L. Benussi , S. Bianco , D. Piccolo , S. Meola , S. Buontempo , F. Carnevali , L. Lista , P. Paolucci , F. Fienga , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , E. Asilar , J. Choi , T. J. Kim , S. Y. Choi , B. Hong , K. S. Lee , H. Y. Oh , J. Goh , I. Yu , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , R. L. Fernandez , M. Ramirez-Garcia , E. Vazquez , M. A. Shah , N. Zaganidis , A. Radi , H. Hoorani , S. Muhammad , A. Ahmad , I. Asghar , W. A. Khan , J. Eysermans , F. Torres Da Silva De Araujo

The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS…

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap…

Instrumentation and Detectors · Physics 2015-06-22 G. Pugliese

The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas…

Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the…

The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central…

Instrumentation and Detectors · Physics 2020-01-29 M. A. Shah , R. Hadjiska

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

A Pilot unit of a closed loop gas (CLS) mixing and distribution system for the INO project was designed and is being operated with (1.8 x 1.9) m^2 glass RPCs (Resistive Plate Chamber). The performance of an RPC depends on the quality and…

Instrumentation and Detectors · Physics 2017-02-07 S. D. Kalmani , S. Mondal , R. R. Shinde , P. V. Hunagund

Resistive Plate Chambers (RPCs), used for the Muon Spectrometer of the ALICE experiment at CERN LHC, are currently operated in maxi-avalanche mode with a low threshold value and without amplification in the front-end electronics. RPC…

Instrumentation and Detectors · Physics 2020-01-29 Antonio Bianchi

The MuCap experiment is a high-precision measurement of the rate for the basic electroweak process of muon capture, mu- + p -> n + nu . The experimental approach is based on an active target consisting of a time projection chamber (TPC)…

ALICE (A Large Ion Collider Experiment) studies the Quark-Gluon Plasma (QGP): a deconfined state of matter obtained in ultra-relativistic heavy-ion collisions. One of the probes for QGP study are quarkonia and open heavy flavour, of which…

The muon identification system of the ALICE experiment at the CERN LHC is based on Resistive Plate Chamber (RPC) detectors. These RPCs are operated in the so-called maxi-avalanche mode with a gas mixture made of tetrafluoroethane…

Instrumentation and Detectors · Physics 2020-01-29 A. Bianchi , S. Delsanto , P. Dupieux , A. Ferretti , M. Gagliardi , B. Joly , S. P. Manen , M. Marchisone , L. Micheletti , A. Rosano , E. Vercellin

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers (RPCs) and Drift Tube (DT) chambers in the barrel, RPC and Cathode…

Instrumentation and Detectors · Physics 2017-06-22 M. I. Pedraza-Morales , M. A. Shaha , M. Shopova

The Phase II upgrade of the ATLAS Muon Spectrometer will involve the installation of approximately 1000 next-generation Resistive Plate Chamber (RPC) singlets. This upgrade aims to enhance detector coverage, increase hit efficiency, and…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah
‹ Prev 1 2 3 10 Next ›