Related papers: Efficient Radio Frequency filters for space constr…
A normal metal - superconductor hybrid single-electron trap with tunable barrier is utilized as a tool for spectrum analysis at the extremely low signal levels, using only well filtered cryogenic microwave background as a photon source in…
We propose and test a cryogenic setup comprising dielectric waveguides for mm-wave frequencies in the range of 75-110 GHz and temperatures down to 10 mK. The targeted applications are quantum technologies at millimeter-wave frequencies,…
Long-lived, high-frequency phonons are valuable for applications ranging from optomechanics to emerging quantum systems. For scientific as well as technological impact, we seek high-performance oscillators that offer a path towards…
The quantum transduction of an rf/microwave signal to the optical domain, and vice versa, paves the way for technologies that exploit the advantages of each domain to perform quantum operations. Since electro-optomechanical devices…
Fast and high-fidelity qubit readout requires strong coupling between the readout resonator and the feedline. However, such coupling unavoidably enhances qubit decay through the Purcell effect. We present a four-pole broadband Purcell…
Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that…
The precision of typical thermometers consisting of $N$ particles is shot noise limited, improving as $\sim1/\sqrt{N}$. For high precision thermometry and thermometric standards this presents an important theoretical noise floor. Here it is…
Formaldehyde, a known human carcinogen, is a common indoor air pollutant. However, its real-time and selective recognition from interfering gases remains challenging, especially for low-power sensors suffering from noise and baseline drift.…
We derive the quantum filter for a quantum open system undergoing quadrature measurements (homodyning) where the input field is in a general quasi-free state. This extends previous work for thermal input noise and allows for squeezed…
The frequency band between $0.1$ and $10\mathrm{Hz}$ remains largely unexplored in gravitational-wave astronomy due to strong seismic, Newtonian, and suspension thermal noise that limit ground-based detectors. The Cryogenic sub-Hz cROss…
The utility of inertial sensors depends on resilience against real-world dynamics and noise. Atom interferometry offers a sensing technology with the advantage of good long-term stability, high sensitivity, and accuracy. High measurement…
In this study, we present the design and analysis of a Low Noise Amplifier tailored specifically for quantum applications. We selected the HEMT for its unique noise reduction properties, crucial for quantum engineering. The main goal is to…
70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described…
Detections of gravitational waves (GW) in the frequency band 35 Hz to 500 Hz have led to the birth of GW astronomy. Expected signals above 500 Hz, such as the quasinormal modes of lower mass black holes and neutron star mergers signatures…
We report on low mechanical loss in a high-stress silicon nitride (Si_{3}N_{4}) membrane at temperatures below 100 mK. We isolate a membrane via a phononic shield formed within a supporting silicon frame, and measure the mechanical quality…
Continuous-wave squeezed states of light at the wavelength of 1550 nm have recently been demonstrated, but so far the obtained factors of noise suppression still lag behind today's best squeezing values demonstrated at 1064 nm. Here we…
Resonant frequency modulation spectroscopy has been previously used as a highly-sensitive method for measuring the output of cold atom interferometers. Using a detailed model that accounts for optical saturation, laser intensities and…
Parametric amplifiers have become a workhorse in superconducting quantum computing, however research and development of these devices has been hampered by inconsistent, and sometimes misleading noise performance characterization…
Low-frequency qubit control wires require non-trivial thermal anchoring and low-pass filtering. The resulting electron temperature serves as a quality benchmark for these signal lines. In this technical note, we make use of a primary…
Quantum systems are exceedingly difficult to engineer because they are sensitive to various types of noises. In particular, time-dependent noises are frequently encountered in experiments but how to overcome them remains a challenging…