English
Related papers

Related papers: Characterization of GEM Detectors for Application …

200 papers

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…

Instrumentation and Detectors · Physics 2018-12-12 Aashaq Shah , CMS-Muon Collaboration

In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger…

Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…

Instrumentation and Detectors · Physics 2014-12-10 D. Abbaneo , M. Abbas , M. Abbrescia , A. A. Abdelalim , M. Abi Akl , W. Ahmed , W. Ahmed , P. Altieri , R. Aly , C. Asawatangtrakuldee , A. Ashfaq , P. Aspell , Y. Assran , I. Awan , S. Bally , Y. Ban , S. Banerjee , P. Barria , L. Benussi , V. Bhopatkar , S. Bianco , J. Bos , O. Bouhali , S. Braibant , S. Buontempo , C. Calabria , M. Caponero , C. Caputo , F. Cassese , A. Castaneda , S. Cauwenbergh , F. R. Cavallo , A. Celik , M. Choi , K. Choi , S. Choi , J. Christiansen , A. Cimmino , S. Colafranceschi , A. Colaleo , A. Conde Garcia , M. M. Dabrowski , G. De Lentdecker , R. De Oliveira , G. de Robertis , S. Dildick , B. Dorney , W. Elmetenawee , G. Fabrice , M. Ferrini , S. Ferry , P. Giacomelli , J. Gilmore , L. Guiducci , A. Gutierrez , R. M. Hadjiiska , A. Hassan , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , Y. G. Jeng , T. Kamon , P. E. Karchin , H. S. Kim , S. Krutelyov , A. Kumar , J. Lee , T. Lenzi , L. Litov , F. Loddo , T. Maerschalk , G. Magazzu , M. Maggi , Y. Maghrbi , A. Magnani , N. Majumdar , P. K. Mal , K. Mandal , A. Marchioro , A. Marinov , J. A. Merlin , A. K. Mohanty , A. Mohapatra , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , S. Nuzzo , E. Oliveri , L. M. Pant , P. Paolucci , I. Park , G. Passeggio , B. Pavlov , B. Philipps , M. Phipps , D. Piccolo , H. Postema , G. Pugliese , A. Puig Baranac , A. Radi , R. Radogna , G. Raffone , S. Ramkrishna , A. Ranieri , C. Riccardi , A. Rodrigues , L. Ropelewski , S. RoyChowdhury , M. S. Ryu , G. Ryu , A. Safonov , A. Sakharov , S. Salva , G. Saviano , A. Sharma , S. K. Swain , J. P. Talvitie , C. Tamma , A. Tatarinov , N. Turini , T. Tuuva , J. Twigger , M. Tytgat , I. Vai , M. van Stenis , R. Venditi , E. Verhagen , P. Verwilligen , P. Vitulo , D. Wang , M. Wang , U. Yang , Y. Yang , R. Yonamine , N. Zaganidis , F. Zenoni , A. Zhang

After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $\eta$ region. To improve both the tracking and…

Instrumentation and Detectors · Physics 2021-12-08 M. Abbas , M. Abbrescia , H. Abdalla , A. Abdelalim , S. AbuZeid , A. Agapitos , A. Ahmad , A. Ahmed , W. Ahmed , C. Aimè , C. Aruta , I. Asghar , P. Aspell , C. Avila , J. Babbar , Y. Ban , R. Band , S. Bansal , L. Benussi , V. Bhatnagar , M. Bianco , S. Bianco , K. Black , L. Borgonovi , O. Bouhali , A. Braghieri , S. Braibant , S. Butalla , S. Calzaferri , M. Caponero , J. Carlson , F. Cassese , N. Cavallo , S. S. Chauhan , S. Colafranceschi , A. Colaleo , A. Conde Garcia , M. Dalchenko , A. De Iorio , G. De Lentdecker , D. Dell Olio , G. De Robertis , W. Dharmaratna , S. Dildick , B. Dorney , R. Erbacher , F. Fabozzi , F. Fallavollita , A. Ferraro , D. Fiorina , E. Fontanesi , M. Franco , C. Galloni , P. Giacomelli , S. Gigli , J. Gilmore , M. Gola , M. Gruchala , A. Gutierrez , R. Hadjiiska , T. Hakkarainen , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , T. Huang , P. Iaydjiev , A. Irshad , A. Iorio , F. Ivone , W. Jang , J. Jaramillo , A. Juodagalvis , E. Juska , B. Kailasapathy , T. Kamon , Y. Kang , P. Karchin , A. Kaur , H. Kaur , H. Keller , H. Kim , J. Kim , S. Kim , B. Ko , A. Kumar , S. Kumar , N. Lacalamita , J. S. H. Lee , A. Levin , Q. Li , F. Licciulli , L. Lista , K. Liyanage , F. Loddo , M. Luhach , M. Maggi , Y. Maghrbi , N. Majumdar , K. Malagalage , S. Malhotra , S. Martiradonna , C. McLean , J. Merlin , M. Misheva , G. Mocellin , L. Moureaux , A. Muhammad , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , S. Nuzzo , R. Oliveira , P. Paolucci , I. C. Park , L. Passamonti , G. Passeggio , A. Peck , A. Pellecchia , N. Perera , L. Petre , H. Petrow , D. Piccolo , D. Pierluigi , G. Raffone , M. Rahmani , F. Ramirez , A. Ranieri , G. Rashevski , B. Regnery , M. Ressegotti , C. Riccardi , M. Rodozov , E. Romano , C. Roskas , B. Rossi , P. Rout , J. D. Ruiz , A. Russo , A. Safonov , A. K. Sahota , D. Saltzberg , G. Saviano , A. Shah , A. Sharma , R. Sharma , T. Sheokand , M. Shopova , F. M. Simone , J. Singh , U. Sonnadara , E. Starling , B. Stone , J. Sturdy , G. Sultanov , Z. Szillasi , D. Teague , D. Teyssier , T. Tuuva , M. Tytgat , I. Vai , N. Vanegas , R. Venditti , P. Verwilligen , W. Vetens , A. K. Virdi , P. Vitulo , A. Wajid , D. Wang , K. Wang , I. J. Watson , N. Wickramage , D. D. C. Wickramarathna , S. Yang , U. Yang , Y. Yang , J. Yongho , I. Yoon , Z. You , I. Yu , S. Zaleski

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions…

Instrumentation and Detectors · Physics 2020-06-09 CMS Muon Group

The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central…

Instrumentation and Detectors · Physics 2020-01-29 M. A. Shah , R. Hadjiska

The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive…

Based on the CMS Upgrade R&D Proposal RD10.02, we describe the motivation and main features of the CMS GEM Project for LS2 and propose the addition of a full GE1/12 detector station comprising Gas Electron Multiplier (GEM) chambers to the…

Instrumentation and Detectors · Physics 2012-12-03 D. Abbaneo , M. Abbrescia , P. Aspell , S. Bianco , K. Hoepfner , M. Hohlmann , M. Maggi , G. De Lentdecker , A. Safonov , A. Sharma , M. Tytgat

Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…

Instrumentation and Detectors · Physics 2016-11-17 M. Hohlmann , K. Gnanvo , L. Grasso , J. B. Locke , A. Quintero , D. Mitra

With the increases in the LHC instantaneous luminosity, maintaining effective triggering and avoiding dead time will become especially challenging. As the sensitivity of many physics studies, depends critically on the ability to maintain…

Instrumentation and Detectors · Physics 2013-10-09 A. Castaneda

The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…

Instrumentation and Detectors · Physics 2018-09-07 Jian Wang

The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon…

Instrumentation and Detectors · Physics 2022-05-18 Stephen D. Butalla , Marcus Hohlmann

The High-Luminosity LHC (HL-LHC, or Phase 2 LHC) will deliver proton-proton collisions at 5-7.5 times the nominal LHC luminosity, with an expected number of 140-200 pp-interactions per bunch crossing (Pile-up or PU). To maintain the…

Instrumentation and Detectors · Physics 2023-07-19 Piet Verwilligen

Single muon triggers are crucial for the physics programmes at hadron collider experiments. To be sensitive to electroweak processes, single muon triggers with transverse momentum thresholds down to 20 GeV and dimuon triggers with even…

Instrumentation and Detectors · Physics 2019-03-27 D. Cieri , S. Abovyan , V. Danielyan , M. Fras , P. Gadow , O. Kortner , S. Kortner , H. Kroha , F. Müller , S. Nowak , P. Richter , K. Schmidt-Sommerfeld

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas…

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

‹ Prev 1 2 3 10 Next ›