Related papers: Stokes imaging polarimetry using image restoration…
This paper presents the High Frequency Instrument (HFI) data processing procedures for the Planck 2018 release. Major improvements in mapmaking have been achieved since the previous 2015 release. They enabled the first significant…
Single-pixel imaging (SPI) exhibits cost-effectiveness, broad spectrum, and stable sub-Nyquist sampling reconstruction, enabling applications across diverse imaging fields.However, due to the inherent reconstruction mechanism, SPI is not…
3D single-pixel imaging (SPI) is a promising imaging technique that can be ffexibly applied to various wavebands. The main challenge in 3D SPI is that the calibration usually requires a large number of standard points as references, which…
Wide-field images made by radio interferometers are invariably affected by direction-dependent systematic effects such as the ionosphere or the beam pattern. Calibration along a set of discrete directions in the sky is the default technique…
In this paper we develop a new approach to the calibration of polarimetric radar data based on two key ideas. The first is the use of in-scene trihedral corner reflectors not only for radiometric and geometric calibration but also to…
This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from…
New generation of radio interferometers are envisaged to produce high quality, high dynamic range Stokes images of the observed sky from the corresponding under-sampled Fourier domain measurements. In practice, these measurements are…
We describe the data reduction algorithms for the Multiband Imaging Photometer for Spitzer (MIPS) instrument. These algorithms were based on extensive preflight testing and modeling of the Si:As (24 micron) and Ge:Ga (70 and 160 micron)…
Context: Polarimetry is a very powerful tool to uncover various properties of astronomical objects that remain otherwise hidden in standard imaging or spectroscopic observations. However, the reliable measurement of the low polarization…
Image slicing is a powerful technique in astronomy. It allows the instrument designer to reduce the slit width of the spectrograph, increasing spectral resolving power whilst retaining throughput. Conventionally this is done using bulk…
The absolute calibration and characterization of the Multiband Imaging Photometer for Spitzer (MIPS) 70 micron coarse- and fine-scale imaging modes are presented based on over 2.5 years of observations. Accurate photometry (especially for…
Limited-angle computerized tomography stands for one of the most difficult challenges in imaging. Although it opens the way to faster data acquisition in industry and less dangerous scans in medicine, standard approaches, such as the…
We present a new matched filter algorithm for direct detection of point sources in the immediate vicinity of bright stars. The stellar Point Spread Function (PSF) is first subtracted using a Karhunen-Lo\'eve Image Processing (KLIP)…
The next generation of solar telescopes will enable us to resolve the fundamental scales of the solar atmosphere, i.e., the pressure scale height and the photon mean free path. High-resolution observations of small-scale structures with…
Different methods for simulating the effects of spatial resolution on magnetic field maps are compared, including those commonly used for inter-instrument comparisons. The investigation first uses synthetic data, and the results are…
The process of data taking, reduction and calibration of near-infrared imaging polarimetry data taken with the ESO Adaptive Optics System ADONIS is described. The ADONIS polarimetric facility is provided by a rotating wire grid polarizer.…
Fourier ptychographic microscopy (FPM) is a recently proposed quantitative phase imaging technique with high resolution and wide field-of-view (FOV). In current FPM imaging platforms, systematic error sources come from the aberrations, LED…
This work introduces a method that applies images of the extended bodies in the solar system to spacecraft camera calibration. The extended bodies consist of planets and moons that are well-modeled by triaxial ellipsoids. When imaged, the…
Increasing the angular resolution of an interferometric array requires placing its elements at large separations. This often leads to sparse coverage and introduces challenges to reconstructing images from interferometric data. We introduce…
A common task in single particle electron cryomicroscopy (cryo-EM) is the rigid alignment of images and/or volumes. In the context of images, a rigid alignment involves estimating the inner-product between one image of $N\times N$ pixels…