English
Related papers

Related papers: The CALICE Software Framework and Operational Expe…

200 papers

Particle Flow Algorithms (PFAs) have been proposed as a method of improving the jet energy resolution of future colliding beam detectors. PFAs require calorimeters with high granularity to enable three-dimensional imaging of events. The…

Instrumentation and Detectors · Physics 2019-08-13 Kurt Francis

I describe parameterizations of realistic $e^\pm$- and $\gamma$-beam spectra at future linear $e^+e^-$-colliders. Emphasis is put on simplicity and reproducibility of the parameterizations, supporting reproducible physics simulations. The…

High Energy Physics - Phenomenology · Physics 2009-10-28 Thorsten Ohl

The CALICE collaboration has constructed a highly granular hadronic calorimeter based on small scintillator tiles read out with silicon photomultipliers. With this detector, data was taken at CERN and at Fermilab. The high granularity of…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The CALICE collaboration has constructed a hadronic sandwich calorimeter prototype with 7608 scintillating plates, individually read out by multi-pixel silicon photomultipliers (SiPMs). For the first time ever the read out is performed…

Instrumentation and Detectors · Physics 2009-02-10 Riccardo Fabbri

Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered…

High Energy Physics - Experiment · Physics 2023-01-24 Ivan Smiljanic

The ALICE Collaboration at CERN developed a 3D visualisation tool capable of displaying a representation of collected collision data (particle trajectories, clusters and calorimeter towers) called the Event Display. The Event Display is…

Instrumentation and Detectors · Physics 2023-09-25 Piotr Nowakowski , Przemysław Rokita , Łukasz Graczykowski

LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…

This paper presents the simulation of the GLAST high energy gamma-ray telescope. The simulation package, written in C++, is based on the Geant4 toolkit, and it is integrated into a general framework used to process events. A detailed…

An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common…

High Energy Physics - Experiment · Physics 2023-04-28 Vincent Boudry

We summarize the recent activity of our group in the calibration, monitoring and gain stabilization of photodetectors, primarily silicon photomultipliers, in calorimeters using scintillator as active medium. The task originally solved for…

Instrumentation and Detectors · Physics 2015-03-25 J. Cvach , M. Janata , M. Kovalcuk , J. Kvasnicka , I. Polak , J. Smolik

We present LEMURS: an extensive dataset of simulated calorimeter showers designed to support the development and benchmarking of fast simulation methods in high-energy physics, most notably providing a step towards the development of…

Instrumentation and Detectors · Physics 2025-11-04 Peter McKeown , Piyush Raikwar , Anna Zaborowska

The software compensation algorithms developed for the CALICE Analog Hadron Calorimeter are extended to incorporate time information on the cell level, and the performance is studied in GEANT4 simulations with a detector model of a…

Instrumentation and Detectors · Physics 2022-08-30 Christian Graf , Frank Simon

ALICE, the experiment dedicated to the study of heavy ion collisions at the LHC, uses an object-oriented framework for simulation, reconstruction and analysis (AliRoot) based on ROOT. Here, we describe the general ALICE simulation strategy…

Computational Physics · Physics 2007-05-23 F. Carminati , A. Morsch

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…

Instrumentation and Detectors · Physics 2014-07-24 CALICE Collaboration , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , M. A. Thomson , D. R. Ward , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , A. Ribon , V. Uzhinskiy , C. Carloganu , P. Gay , S. Manen , L. Royer , M. Tytgat , N. Zaganidis , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , A. Ebrahimi , G. Falley , K. Gadow , P. Goettlicher , C. Guenter , O. Hartbrich , B. Hermberg , S. Karstensen , F. Krivan , K. Krueger , B. Lutz , S. Morozov , V. Morgunov , C. Neubueser , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , E. Garutti , S. Laurien , S. Lu , I. Marchesini , M. Matysek , M. Ramilli , K. Briggl , P. Eckert , T. Harion , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , G. W. Wilson , K. Kawagoe , Y. Sudo , T. Yoshioka , P. D. Dauncey , M. Wing , F. Salvatore , E. Cortina Gil , S. Mannai , G. Baulieu , P. Calabria , L. Caponetto , C. Combaret , R. Della Negra , G. Grenier , R. Han , J-C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeur , M. Vander Donckt , Y. Zoccarato , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , F. Corriveau , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , D. Besson , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , J. Rouene , N. Seguin-Moreau , M. Anduze , V. Balagura , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , E. Guliyev , Y. Haddad , F. Magniette , G. Musat , M. Ruan , T. H. Tran , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , H. Ono , T. Takeshita , S. Uozumi , D. Jeans , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , M. Goetze , J. Sauer , S. Weber , C. Zeitnitz

In this article, we present a recently released R package for Bayesian calibration. Many industrial fields are facing unfeasible or costly field experiments. These experiments are replaced with numerical/computer experiments which are…

Computation · Statistics 2018-08-30 Mathieu Carmassi , Pierre Barbillon , Matthieu Chiodetti , Merlin Keller , Eric Parent

In order to profit from the high granularity of the calorimeters proposed for the ILC that are suitable for the Particle Flow Approach, specialised clustering algorithms have to be developped. GARLIC is such an algorithm with the goal to…

High Energy Physics - Experiment · Physics 2009-02-19 Marcel Reinhard , Jean-Claude Brient

Detectors at future e+e- collider need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered…

Instrumentation and Detectors · Physics 2012-02-01 Ivanka Bozovic-Jelisavcic

A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination…

Instrumentation and Detectors · Physics 2019-08-14 T. Peitzmann

A software package has been developed to bridge the R analysis model with the conceptual analysis environment typical of radiation physics experiments. The new package has been used in the context of a project for the validation of…

Computational Physics · Physics 2013-11-25 Andreas Pfeiffer , Maria Grazia Pia

preCICE is a free/open-source coupling library. It enables creating partitioned multi-physics simulations by gluing together separate software packages. This paper summarizes the development efforts in preCICE of the past five years. During…