Related papers: New Insights into Particle Detection with Superhea…
The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of…
The combined measurement of dark matter interactions with different superheated liquids has recently been suggested as a cross-correlation technique in identifying WIMP candidates. We describe the fabrication of high concentration…
It is shown that under realistic background considerations, an improvement in Cold Dark Matter sensitivity of several orders of magnitude is expected from a detector based on superheated liquid droplets. Such devices are totally insensitive…
We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of…
Energy calibration of superheated droplet detector is discussed in terms of the effective recoil nucleus threshold energy and the reduced superheat. This provides a universal energy calibration curve valid for different liquids used in this…
The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection…
Superheated droplets are proven to be excelent detectors for neutrons and could be used as a neutron dosimeter. To detect accurately the volume of the vapour formed upon nucleation and hence to observe the nucleation quantitatively an air…
Superheated drops are known to vaporise when exposed to energetic nuclear radiation since the discovery of bubble chamber. As the degree of superheat increases in a given liquid, less and less energetic neutrons are required to cause…
The PICO experiment uses bubble chambers filled with superheated C$_3$F$_8$ for spin-dependent WIMP dark matter searches. One of the main sources of background in these detectors is alpha particles from decays of environmental…
Bubble chambers and droplet detectors used in dosimetry and dark matter particle search experiments use a superheated metastable liquid in which nuclear recoils trigger bubble nucleation. This process is described by the classical heat…
We suggest the use of moderately superheated liquids in the form of superheated droplet detectors for a new type of neutralino search experiment. The advantage of this method for Dark Matter detection is, that the detector material is…
The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerized gel. This detection…
Superheated drops are known to detect neutrons through the nucleation caused by the recoil nuclei produced by the interactions of neutrons with the atoms constituting the superheated liquid molecule. A novel method of finding the neutron…
The SIMPLE Collaboration has reported results from their superheated C2ClF5 droplet detectors, including a description of acoustic discrimination between \alpha decays and nuclear recoils. Our concern is that the events in the neutron…
We discuss the operation principle of a detector based on superheated droplets of Freon-12 and its feasibility for the search of weakly interacting cold dark matter particles. In particular we are interested in a neutralino search…
Phase II of SIMPLE (Superheated Instrument for Massive ParticLe Experiments) searched for astroparticle dark matter using superheated liquid C$_{2}$ClF$_{5}$ droplet detectors. Each droplet generally requires an energy deposition with…
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent…
The bubble nucleation in superheated liquid can be controlled by adjusting the ambient pressure and temperature. At higher pressure the threshold energy for bubble nucleation increases and we have observed that the amplitude of the acoustic…
The bubble nucleation process in superheated droplet detector (SDD) is associated with the emission of an acoustic pulse that can be detected by an acoustic sensor. We have studied the neutron and gamma-ray induced nucleation events in a…
Ton-scale direct dark matter search experiments should be sensitive to neutrino-induced recoil events from either $^8$B solar neutrinos or the brief but intense flux from a core collapse supernova in the Milky Way. These low-threshold…