English
Related papers

Related papers: \textsc{MaGe} - a {\sc Geant4}-based Monte Carlo A…

200 papers

Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development…

Instrumentation and Detectors · Physics 2024-10-14 Lysander Miller , Airlie Chapman , Katie Auchettl , Jeremy M. C. Brown

The GERmanium Detector Array (GERDA) is a low background experiment located at the Laboratori Nazionali del Gran Sasso in Italy, which searches for neutrinoless double beta decay of $^{76}$Ge into $^{76}$Se+2e$^-$. GERDA has been conceived…

Instrumentation and Detectors · Physics 2021-04-10 GERDA collaboration , M. Agostini , A. M. Bakalyarov , E. Andreotti , M. Balata , I. Barabanov , L. Baudis , N. Barros , C. Bauer , E. Bellotti , S. Belogurov , G. Benato , A. Bettini , L. Bezrukov , T. Bode , D. Borowicz , V. Brudanin , R. Brugnera , D. Budjáš , A. Caldwell , C. Cattadori , A. Chernogorov , V. D'Andrea , E. V. Demidova , N. Di Marco , A. Domula , E. Doroshkevich , V. Egorov , R. Falkenstein , K. Freund , A. Gangapshev , A. Garfagnini , C. Gooch , P. Grabmayr , V. Gurentsov , K. Gusev , J. Hakenmüller , A. Hegai , M. Heisel , S. Hemmer , R. Hiller , W. Hofmann , M. Hult , L. V. Inzhechik , J. Janicskó Csáthy , J. Jochum , M. Junker , V. Kazalov , Y. Kermaidic , T. Kihm , I. V. Kirpichnikov , A. Kirsch , A. Kish , A. Klimenko , R. Kneißl , K. T. Knöpfle , O. Kochetov , V. N. Kornoukhov , V. V. Kuzminov , M. Laubenstein , A. Lazzaro , B. Lehnert , Y. Liao , M. Lindner , I. Lippi , A. Lubashevskiy , B. Lubsandorzhiev , G. Lutter , C. Macolino , B. Majorovits , W. Maneschg , M. Miloradovic , R. Mingazheva , M. Misiaszek , P. Moseev , I. Nemchenok , K. Panas , L. Pandola , K. Pelczar , A. Pullia , C. Ransom , S. Riboldi , N. Rumyantseva , C. Sada , F. Salamida , M. Salathe , C. Schmitt , B. Schneider , S. Schönert , A-K. Schütz , O. Schulz , B. Schwingenheuer , O. Selivanenko , E. Shevchik , M. Shirchenko , H. Simgen , A. Smolnikov , L. Stanco , C. A. Ur , L. Vanhoefer , A. A. Vasenko , A. Veresnikova , K. von Sturm , V. Wagner , A. Wegmann , T. Wester , C. Wiesinger , M. Wojcik , E. Yanovich , I. Zhitnikov , S. V. Zhukov , D. Zinatulina , A. J. Zsigmond , K. Zuber , G. Zuzel

The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses…

The search for neutrinoless double-beta decay is the most sensitive technique to establish the Majorana nature of neutrinos. Two operating experiments that look for such decays in $^{76}$Ge -- GERDA and the MAJORANA DEMONSTRATOR -- have…

Instrumentation and Detectors · Physics 2019-08-14 Jordan Myslik

Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The Majorana Collaboration proposes to assemble an…

Nuclear Experiment · Physics 2019-08-13 V. E. Guiseppe

The Majorana Experiment will use arrays of enriched HPGe detectors to search for the neutrinoless double-beta decay of 76Ge. Such a decay, if found, would show lepton-number violation and confirm the Majorana nature of the neutrino.…

Nuclear Experiment · Physics 2015-06-03 R. A. Johnson , T. H. Burritt , S. R. Elliott , V. M. Gehman , V. E. Guiseppe , J. F. Wilkerson

High purity germanium (HPGe) crystals will be used for the MAJORANA DEMONSTRATOR, where they serve as both the source and the detector for neutrinoless double beta decay. It is crucial for the experiment to understand the performance of the…

For several years, attempts have been made to interface Geant4 and other software packages with the aim of simulating the complete response of a gaseous particle detector. In such a simulation, Geant4 is always responsible for the primary…

A linear Breit-Wheeler module for the code Geant4 has been developed. This allows signal-to-noise ratio calculations of linear Breit-Wheeler detection experiments to be performed within a single framework. The interaction between two photon…

Plasma Physics · Physics 2023-05-31 R. A. Watt , S. J. Rose , B. Kettle , S. P. D. Mangles

Experiments measuring fission observables encounter false coincidences arising from timing overlap of separate fission product decays. Simulations of both fission observables and particles in detector systems exist, but have not yet been…

Instrumentation and Detectors · Physics 2025-06-10 Liam Walker , Jack Shire , Jacob Jaffe , Payton Sprando , Jack Olinger , Alexander Chemey

We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed…

We describe the LHCb detector simulation application (Gauss) based on the Geant4 toolkit. The application is built using the Gaudi software framework, which is used for all event-processing applications in the LHCb experiment. The existence…

Computational Physics · Physics 2007-05-23 I. Belyaev , Ph. Charpentier , S. Easo , P. Mato , J. Palacios , W. Pokorski , F. Ranjard , J. van Tilburg

The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation. Segmented germanium detectors can be used to identify photons and thus reduce…

Nuclear Experiment · Physics 2008-11-26 I. Abt , A. Caldwell , K. Kröninger , J. Liu , X. Liu , B. Majorovits

High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays…

To increase by a major step the present sensitivity for dark matter and double beta decay search, a new project is suggested, which would operate 'naked' GErmanium detectors in liquid NItrogen as shielding in an Underground Setup (GENIUS).…

High Energy Physics - Phenomenology · Physics 2007-05-23 H. V. Klapdor-Kleingrothaus , L. Baudis , G. Heusser , B. Majorovits , H. Paes

In this paper we investigate, with a detailed Monte-Carlo simulation based on Geant4, the novel approach [Nucl. Instrum. Methods A588 (2008) 457] to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used…

Medical Physics · Physics 2011-09-23 M. Lenti , M. Veltri

A high efficiency, low background counting setup has been made at TIFR consisting of a special HPGe detector ($\sim$ 70%) surrounded by a low activity copper+lead shield. Detailed measurements are performed with point and extended geometry…

Instrumentation and Detectors · Physics 2014-08-21 N. Dokania , V. Singh , S. Mathimalar , V. Nanal , S. Pal , R. G. Pillay

The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding…

Instrumentation and Methods for Astrophysics · Physics 2009-12-02 S. Hauf , M. Kuster , M. G. Pia , Z. Bell , U. Briel , R. Chipaux , D. H. H. Hoffmann , E. Kendziorra , P. Laurent , L. Strüder , C. Tenzer , G. Weidenspointer , A. Zoglauer