Related papers: Evaluation of Compton scattering sequence reconstr…
Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental…
The recent development of scintillation crystals combined with $\gamma$-rays sources opens the way to an imaging concept based on Compton scattering, namely Compton scattering tomography (CST). The associated inverse problem rises many…
Accurate reconstruction of recoil-electron directions is critical for enhancing the point-spread function of electron-tracking Compton cameras (ETCCs) in gamma-ray imaging. Although full three-dimensional (3D) readout systems achieve…
We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe…
The development of germanium Compton telescopes for nuclear gamma-ray astrophysics (~0.2-20 MeV) requires new event reconstruction techniques to accurately determine the initial direction and energy of photon events, as well as to…
PETALO (Positron Emission TOF Apparatus based on Liquid xenOn) exploits the unique characteristics of liquid xenon as a scintillator for use in a PET detector. Here initial simulation studies are detailed which highlight the potential of…
Compton cameras (CCs) are a kind of gamma cameras which are designed to determine the directions of incident gammas based on the Compton scatter. However, the reconstruction of CCs face problems of severe artifacts and deformation due to…
Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…
COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of…
Results from the simulations of a Compton gamma camera based on compact configuration of detectors consisting in two detection modules, each of them having two stages of high-resolution position- and energy-sensitive radiation detectors…
Cosmic ray muon computed tomography ({\mu}CT) is a new imaging modality with unique characteristics that could be particularly important for diverse applications including nuclear nonproliferation, spent nuclear fuel monitoring, cargo…
We have been developing a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60…
Coded Aperture Imaging (CAI) has been proposed as an alternative collimation technique in nuclear imaging. To maximize spatial resolution small pinholes in the coded aperture mask are required. However, a high-resolution detector is needed…
Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide…
A novel method for localization and estimation of compact sources of gamma radiation for Micro Aerial Vehicles (MAVs) is presented in this paper. The method is developed for a novel single-detector Compton camera, developed by the authors.…
A Compton/Pair telescope, designed to provide spectral resolved images of cosmic photons from sub-MeV to GeV energies, records a wealth of data in a combination of tracking detector and calorimeter. Onboard event classification can be…
In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…
We present a Monte Carlo collisional scheme that models single Compton scattering between leptons and photons in particle-in-cell codes. The numerical implementation of Compton scattering can deal with macro-particles of different weights…
Coplanar-grid (CPG) particle detectors were designed for materials such as CdZnTe (CZT) in which charge carriers of only one sign have acceptable transport properties. The presence of two independent anode signals allows for a…