Related papers: A High-resolution Scintillating Fiber Tracker With…
Imaging hadronic calorimeters with scintillator readout use small scintillator tiles individually read out by silicon photomultipliers to achieve the necessary granularity needed for sophisticated reconstruction algorithms at future…
Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…
An intense 146 MeV/c pion beam was stopped inside a scintillating fiber detector made out of 12 planes with 16 pixels each, where every pixel consists out of 8 times 8 scintillating fibers of 500 mkm diameter dense packed. The detector was…
The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…
Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…
The matrices formed of silicon photomultipliers (SiPMs) are very promising photosensors for the scintillation detectors. The use of SiPM matrices with appropriate optical collector gives, in principle, a possibility to do a snapshot of…
Purpose: To demonstrate a proton imaging system based on well-established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use. Methods:…
The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…
A scintillation muon telescope module with fiber-optic light collection using silicon photomultipliers was developed, tested, and installed for continuous monitoring to study cosmic ray variations. The aim of this study was to create a…
Plastic scintillators are widely used for the detection of elementary particles, and 3D reconstruction of particle tracks is achieved by segmenting the detector into 3D granular structures. In this study, we present a novel prototype…
We present preliminary results on efficiency and light collection uniformity read out performances of different assemblies of scintillator tiles, coupled with solid state photon detectors of different make. Our test beam data suggest that…
A fiber detector concept has been realized allowing to registrate particles within less than 100 nsec with a space point precision of about 0.1 mm at low occupancy. Three full size prototypes have been build by different producers and…
Silicon photomultipliers (SiPMs) are semiconductor-based light-sensors offering a high gain, a mechanically and optically robust design and high photon detection efficiency. Due to these characteristics, they started to replace conventional…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…
Tomographic imaging techniques using the Coulomb scattering of cosmic-ray muons are increasingly being exploited for the non-destructive assay of shielded containers in a wide range of applications. One such application is the…
This study constructs a hybrid module with a multi-material collaborative detection architecture by integrating silicon pixel layers into the longitudinally segmented scintillating fiber sampling calorimeter module and optimizes the…
Light yield and spatial uniformity for a large variety of configurations of scintillator tiles was studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light…
We report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5 cm diameter x 5 cm thick and 7 cm diameter x 7 cm thick {\it trans}-stilbene crystals read out with the passively summed output of three different…
We present light yield and uniformity measurements of square and hexagonal tiles read out with silicon photomultipliers via a Y11 wavelength-shifting fiber or directly from the side or from the center at the top face. All tiles are 3~mm…
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…