Related papers: SST polarization model and polarimeter calibration
We present the polarization calibration of the 19-beam receiver at 1420 MHz within the full illumination of the Five-hundred-meter Aperture Spherical Telescope from October 2018 to March 2023. We perform spider observations to characterize…
Mueller matrices provide a complete description of a medium's response to excitation by polarized light, and their characterization is important across a broad range of applications from ellipsometry in material science to polarimetry in…
Taking advantage of the advances in array detector technology, an imaging polarimeter (IMPOL) has been constructed for measuring linear polarization in the wavelength band from 400-800 nm. It makes use of a Wollaston prism as the analyser…
This paper describes a concept for the high-accuracy absolute calibration of the instrumental polarization introduced by the primary mirror of a large-aperture telescope. This procedure requires a small aperture with polarization…
The SST-1M is a 4-m diameter mirror Davies-Cotton gamma-ray telescope. It has been designed to cover the energy range above 500 GeV and to be part of an array of telescopes separated by 150-200 m. Its innovative camera is featuring large…
We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…
A simple, self-calibrating, rotating-waveplate polarimeter is largely insensitive to light intensity fluctuations and is shown to be useful for determining the Stokes parameters of light. This study shows how to minimize the in situ…
We designed, built, and calibrated a new spectropolarimeter for the HiVIS spectrograph (R 12000-49000) on the AEOS telescope. We also did a polarization calibration of the telescope and instrument. We will introduce the design and use of…
The search for inflationary primordial gravitational waves and the measurement of the optical depth to reionization, both through their imprint on the large angular scale correlations in the polarization of the cosmic microwave background…
An easily constructed and operated polarimeter precisely determines the relative Stokes parameters that characterize the polarization of laser light. The polarimeter is calibrated in situ without removing or realigning its optical elements,…
A new method for absolute polarimetric calibration of large telescopes is presented. The proposed method is highly accurate and is based on the calibration of a small sub-aperture, which is then extended to the full system by means of…
We present a method based on Mueller calculus to calibrate linear polarimetric observations. The key advantages of the proposed way of calibration are: (1) that it can be implemented in a data reduction pipeline, (2) that it is possible to…
We present a pipeline that allows recovering reliable information for all four Stokes parameters with high accuracy. Its novelty relies on the treatment of the instrumental effects already prior to the computation of the Stokes parameters…
NICMOS cameras 1 and 2 each carry a set of three polarizing elements to provide high sensitivity observations of linearly polarized light. The polarizers are bandpass limited and provide diffraction-limited imaging in camera 1 at 0.8 -…
The DKIST is designed to deliver accurate spectropolarimetric calibrations across a wide wavelength range and large field of view for solar observations. Instruments deliver spectral resolving powers up to 300,000 in multiple cameras of…
Polarimetric interferometry is a method allowing the study of the distribution of polarized flux at diffraction-limited resolution. Its basic observable is the ratio $\mathcal{R}$ of the visibilities of the object in two orthogonal…
The findings of a nine orbit calibration plan carried out during HST Cycle 15, to fully determine the NICMOS camera 2 (2.0 micron) polarization calibration to high accuracy, are reported. Recently Ueta et al. and Batcheldor et al. have…
The value of accurately knowing the absolute calibration of the polarizing elements in the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) becomes especially important when conducting studies which require measuring degrees of…
Four Stokes parameters (1852) define the polarisation state of light. Measured changes of the Stokes vector of light traversing an inhomogeneous sample are linked to the local anisotropies of absorption and refraction and are harnessed over…
A high degree of linear polarization measured in the optical emission is an important observational feature of blazars. It provides strong evidence of the presence of relativistic particles and magnetic field ordering in the non-thermal…