Related papers: Response of a TeO_2 bolometer to alpha particles
An active discrimination of the dominant $\alpha$-background is the prerequisite for future neutrinoless double-beta decay experiments based on TeO$_{2}$ bolometers. We investigate such $\alpha$-particle rejection in cryogenic TeO$_{2}$…
We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g each, show an…
Bolometers are ideal devices in the search for neutrinoless Double Beta Decay. Enlarging the mass of individual detectors would simplify the construction of a large experiment, but would also decrease the background per unit mass induced by…
Among the detectors used for rare event searches, such as neutrinoless Double Beta Decay (0$\nu$DBD) and Dark Matter experiments, bolometers are very promising because of their favorable properties (excellent energy resolution, high…
In the present work, we describe the results obtained with a large ($\approx 133$ cm$^3$) TeO$_2$ bolometer, with a view to a search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{130}$Te. We demonstrate an efficient $\alpha$…
We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different…
Bolometric detectors are excellent devices for the investigation of neutrinoless double-beta decay (0$\nu\beta\beta$). The observation of such decay would demonstrate the violation of lepton number, and at the same time it would necessarily…
We investigate the performances of two ZnMoO4 scintillating crystals operated as bolometers, in view of a next generation experiment to search the neutrinoless double beta decay of Mo-100. We present the results of the alpha vs beta/gamma…
CUORE, an array of 988 TeO$_2$ bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the background from $\alpha$ radioactivity.…
Bolometric detectors are used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. By operating at cryogenic temperatures, they are able to detect particle…
A large cylindrical cadmium molybdate crystal with natural isotopic abundance has been used to fabricate a scintillating bolometer. The measurement was performed above ground at milli-Kelvin temperature, with simultaneous readout of the…
The first detailed study on the performance of a ZnO-based cryogenic scintillating bolometer as a detector to search for rare processes in zinc isotopes was performed. A 7.2 g ZnO low-temperature detector, containing more than 80\% of zinc…
We report on the development of thermal detectors based on large-size tellurium dioxide crystals (45x45x45 mm), containing tellurium enriched in $^{130}$Te to about 91%, for the CROSS double-beta decay experiment. A powder used for the…
We report the performance of two prototype TeO2 macrobolometers, operated at ~25 mK, able to identify events due to energy deposited at the detector surface. This capability is obtained by thermally coupling thin Ge active layers to the…
The cryogenic phonon scintillating bolometer is a promising and extremely attractive option to search for the nuclide neutrinoless double beta decay. In this paper, a pre-study of bolometer based on Li2MoO4 (LMO) crystal is presented, in…
Neutrinoless double beta decay (0nbb) is a direct probe of physics beyond the Standard Model. Its discovery would demonstrate that the lepton number is not a symmetry of nature and would provide us with unique information on the nature and…
Active background reduction in high resolution calorimeters is a promising approach to achieve ultimate sensitivity in neutrinoless double beta decay experiments. We propose Cerenkov emission from beta rays in bolometric crystals as a…
We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors…
Bolometers have proven to be good instruments to search for rare processes because of their excellent energy resolution and their extremely low intrinsic background. In this kind of detectors, the capability of discriminating alpha…
The next generation of cosmology space missions will be sensitive to parasitic signals arising from cosmic rays. Using a composite bolometer, we have investigated pulses produced by $\alpha$ particles in order to understand the movement of…