Related papers: Charge sensing amplification via weak values measu…
Recently, biased weak measurement(BWM) has shown higher precision than both conventional measurement and standard weak measurement(SWM) in optical metrology. In this paper, we propose a scheme of detecting rotation velocity in Sagnac's…
We study the amplification of weak magnetic field with Weak-value technique based on Faraday magneto-optic effect. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have demonstrated the…
The weak value of an observable is experimentally accessible by weak measurements as theoretically analyzed by Aharonov et al. and recently experimentally demonstrated. We introduce a weak operator associated with the weak values and give a…
Improving the phase resolution of interferometry is crucial for high-precision measurements of various physical quantities. Systematic phase errors dominate the phase uncertainties in most realistic optical interferometers. Here we propose…
Precision measurements of ultra-small linear velocities of one of the mirrors in a Michelson interferometer are performed using two different weak-values techniques. We show that the technique of Almost-Balanced Weak Values (ABWV) offers…
In this article we present an experimental proposal for the estimation of an optomechanical parameter in the presence of noise. The estimation is based on the technique of weak value amplification which can enlarge the radiation pressure…
Weak measurement is unique in enabling measurements of non-commuting operators as well as otherwise-undetectable peculiar phenomena predicted by the Two-State-Vector-Formalism (TSVF). This article, the first in two parts, explores novel…
We present a proof-of-concept experiment aimed at increasing the sensitivity of temperature sensors implemented with Fiber Bragg gratings by making use of a weak value amplification scheme. The technique requires only linear optics elements…
We study the amplification of rotation velocity with the Sagnac interferometer based on the concept of weak-value amplification. By using a different scheme to perform the Sagnac interferometer with the probe in momentum space, we have…
Historically, weak values have been associated with weak measurements performed on quantum systems. Over the past two decades, a series of works have shown that weak values can be determined via measurements of arbitrary strength. One such…
The viability of quantum communication schemes rely on sending quantum states of light over long distances. However, transmission loss can degrade the signal strength, adding noise. Heralded noiseless amplification of a quantum signal can…
We theoretically investigated the dephasing in an Aharonov-Bohm interferometer containing a lateral double quantum dot induced by coupling with a quantum dot charge sensor. We employed the interpolative 2nd-order perturbation theory to…
We report on a study of complementarity in a two-terminal "closed-loop" Aharonov-Bohm interferometer. In this interferometer, the simple picture of two-path interference cannot be applied. We introduce a nearby quantum point contact to…
In the weak measurement formalism of Y. Aharonov et al. the so-called weak value A_w of any observable A is generally a complex number. We derive a physical interpretation of its value in terms of the shift in the measurement pointer's mean…
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two…
The task of wavefront sensing is to measure the phase of the optical field. Here, we demonstrate that the widely used Shack-Hartmann wavefront sensor detects the weak value of transverse momentum, usually achieved by the method of quantum…
In a quantum-noise limited system, weak-value amplification using post-selection normally does not produce more sensitive measurements than standard methods for ideal detectors: the increased weak value is compensated by the reduced power…
Weak values of the spin operator Sz of massive particles, more precisely neutrons, have been experimentally determined by applying a novel measurement scheme. This is achieved by coupling the neutron's spin weakly to its spatial degree of…
We study the detection capability of the weak-value amplification on the basis of the statistical hypothesis testing. We propose a reasonable testing method in the physical and statistical senses to find that the weak measurement with the…
We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative…