English
Related papers

Related papers: GPU-based Low-dose 4DCT Reconstruction via Tempora…

200 papers

This paper introduces a novel method for reconstructing cone beam computed tomography (CBCT) images for arbitrary orbits using a differentiable shift-variant filtered backprojection (FBP) neural network. Traditional CBCT reconstruction…

Computer Vision and Pattern Recognition · Computer Science 2024-10-22 Chengze Ye , Linda-Sophie Schneider , Yipeng Sun , Mareike Thies , Siyuan Mei , Andreas Maier

Reconstructing dynamic, time-varying scenes with computed tomography (4D-CT) is a challenging and ill-posed problem common to industrial and medical settings. Existing 4D-CT reconstructions are designed for sparse sampling schemes that…

Image and Video Processing · Electrical Eng. & Systems 2021-04-26 Albert W. Reed , Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley , Jingu Kang , Suren Jayasuriya

Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing motion artifacts,…

Computer Vision and Pattern Recognition · Computer Science 2025-06-17 Yuan Gao , Shaoyan Pan , Mingzhe Hu , Huiqiao Xie , Jill Remick , Chih-Wei Chang , Justin Roper , Zhen Tian , Xiaofeng Yang

Fourier Ptychographic Microscopy (FPM) is a computational imaging technique that enables high-resolution imaging over a large field of view. However, its application in the biomedical field has been limited due to the long image…

Image and Video Processing · Electrical Eng. & Systems 2024-08-27 Ruiqing Sun , Delong Yang , Yiyan Su , Shaohui Zhang , Qun Hao

The Computed Tomography (CT) for diagnosis of lesions in human internal organs is one of the most fundamental topics in medical imaging. Low-dose CT, which offers reduced radiation exposure, is preferred over standard-dose CT, and therefore…

Image and Video Processing · Electrical Eng. & Systems 2023-09-26 Wenjie Liu

Cone beam computed tomography (CBCT)-guided puncture has become an established approach for diagnosing and treating early- to mid-stage thoracic tumours, yet the associated radiation exposure substantially elevates the risk of secondary…

Computer Vision and Pattern Recognition · Computer Science 2025-12-02 Haoshen Wang , Lei Chen , Wei-Hua Zhang , Linxia Wu , Yong Luo , Zengmao Wang , Yuan Xiong , Chengcheng Zhu , Wenjuan Tang , Xueyi Zhang , Wei Zhou , Xuhua Duan , Lefei Zhang , Gao-Jun Teng , Bo Du , Huangxuan Zhao

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…

Circular cone-beam (CCB) Computed Tomography (CT) has become an integral part of industrial quality control, materials science and medical imaging. The need to acquire and process each scan in a short time naturally leads to trade-offs…

Image and Video Processing · Electrical Eng. & Systems 2020-10-02 Marinus J. Lagerwerf , Daniel M Pelt , Willem Jan Palenstijn , K Joost Batenburg

X-ray Computed Tomography (CT) is an important tool in medical imaging to obtain a direct visualization of patient anatomy. However, the x-ray radiation exposure leads to the concern of lifetime cancer risk. Low-dose CT scan can reduce the…

Medical Physics · Physics 2018-10-30 Guoyang Ma , Chenyang Shen , Xun Jia

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

Image and Video Processing · Electrical Eng. & Systems 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

Low-dose CT imaging requires reconstruction from noisy indirect measurements which can be defined as an ill-posed linear inverse problem. In addition to conventional FBP method in CT imaging, recent compressed sensing based methods exploit…

Image and Video Processing · Electrical Eng. & Systems 2025-11-14 Mehmet Ozan Unal , Metin Ertas , Isa Yildirim

This paper applies the recent fast iterative neural network framework, Momentum-Net, using appropriate models to low-dose X-ray computed tomography (LDCT) image reconstruction. At each layer of the proposed Momentum-Net, the model-based…

Image and Video Processing · Electrical Eng. & Systems 2020-09-10 Siqi Ye , Yong Long , Il Yong Chun

In this study we evaluated the task-based image quality of a low contrast clinical task for the abdomen protocol (e.g., pancreatic tumour) of three different CT vendors, exploiting three model-based iterative reconstruction (MBIR) levels.…

Medical Physics · Physics 2023-01-23 G. Muti , S. Riga , L. Berta , D. Curto , C. De Mattia , M. Felisi , F. Rizzetto , A. Torresin , A. Vanzulli , P. E. Colombo

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations…

Four-dimensional MRI (4D-MRI) is an promising technique for capturing respiratory-induced motion in radiation therapy planning and delivery. Conventional 4D reconstruction methods, which typically rely on phase binning or separate template…

Computer Vision and Pattern Recognition · Computer Science 2025-09-24 Xinyang Wu , Muheng Li , Xia Li , Orso Pusterla , Sairos Safai , Philippe C. Cattin , Antony J. Lomax , Ye Zhang

Our aim was to enhance visual quality and quantitative accuracy of dynamic positron emission tomography (PET)uptake images by improved image reconstruction, using sophisticated sparse penalty models that incorporate both 2D spatial+1D…

Computer Vision and Pattern Recognition · Computer Science 2019-06-17 Ida Häggström , Yizun Lin , Si Li , Andrzej Krol , Yuesheng Xu , C. Ross Schmidtlein

Low dose X-ray computed tomography (LDCT) is desirable for reduced patient dose. This work develops image reconstruction methods with deep learning (DL) regularization for LDCT. Our methods are based on unrolling of proximal…

Image and Video Processing · Electrical Eng. & Systems 2020-08-26 Qiaoqiao Ding , Gaoyu Chen , Xiaoqun Zhang , Qiu Huang , Hui Jiand Hao Gao

Motion during acquisition of a set of projections can lead to significant motion artifacts in computed tomography reconstructions despite fast acquisition of individual views. In cases such as cardiac imaging, motion may be unavoidable and…

Image and Video Processing · Electrical Eng. & Systems 2022-01-19 Kunal Gupta , Brendan Colvert , Francisco Contijoch

4D time-space reconstruction of dynamic events or deforming objects using X-ray computed tomography (CT) is an important inverse problem in non-destructive evaluation. Conventional back-projection based reconstruction methods assume that…

Image and Video Processing · Electrical Eng. & Systems 2025-02-27 K. Aditya Mohan , Massimiliano Ferrucci , Chuck Divin , Garrett A. Stevenson , Hyojin Kim

Limited data and low dose constraints are common problems in a variety of tomographic reconstruction paradigms which lead to noisy and incomplete data. Over the past few years sinogram denoising has become an essential pre-processing step…

Computer Vision and Pattern Recognition · Computer Science 2016-03-15 Faisal Mahmood , Nauman Shahid , Pierre Vandergheynst , Ulf Skoglund