Related papers: Numerical control matrix rotation for the LINC-NIR…
The National Ignition Facility (NIF) requires that pulses from each of the 192 laser beams be positioned on target with an accuracy of 50 um rms. Beam quality must be sufficient to focus a total of 1.8 MJ of 0.351-um light into a…
Light scattering inhibits high-resolution optical imaging, manipulation and therapy deep inside biological tissue by preventing focusing. To form deep foci, wavefront-shaping and time-reversal techniques that break the optical diffusion…
The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore's law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend…
Quantum imaging with spatially entangled photons offers advantages such as enhanced spatial resolution, robustness against noise, and counter-intuitive phenomena, while a biphoton spatial aberration generally degrades its performance.…
Recording changes in beam transverse positions re-ported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector (orbit response) is a powerful tool for analysis of accelerator optics and assisting…
An adaptive optics system with a single deformable mirror is being implemented on the THEMIS 90cm solar telescope. This system is designed to operate in the visible and is required to be as robust as possible in order to deliver the best…
The increased need in pointing performance for Earth observation and science Space missions together with the use of lighter and flexible structures directly come with the need of a robust pointing performance budget from the very beginning…
We study a mid-order wavefront sensor (MOWFS) to address fine cophasing errors in exoplanet imaging with future large segmented aperture space telescopes. Observing Earth analogs around Sun-like stars requires contrasts down to $10^{-10}$…
Adaptive optics is a strategy to compensate for sample-induced aberrations in microscopy applications. Generally, it requires the presence of "guide stars" in the sample to serve as localized reference targets. We describe an implementation…
The pyramid wavefront sensor (PyWFS) has become increasingly popular to use in adaptive optics (AO) systems due to its high sensitivity. The main drawback of the PyWFS is that it is inherently nonlinear, which means that classic linear…
Imaging faint objects, such as exoplanets or disks, around nearby stars is extremely challenging because host star images are dominated by the telescope diffraction pattern. Using a coronagraph is an efficient solution for removing…
As we look to the next generation of adaptive optics systems, now is the time to develop and explore the technologies that will allow us to image rocky Earth-like planets; wavefront control algorithms are not only a crucial component of…
We investigate methods to calibrate the non-common path aberrations at an adaptive optics system having a wavefront-correcting device working at an extremely high resolution (larger than 150x150). We use focal-plane images collected…
MORFEO (Multi-conjugate adaptive Optics Relay For ELT Observation) is the future multi-conjugate adaptive optics system for the ESO ELT that will feed the instrument MICADO (Multi-AO Imaging Camera for Deep Observations). It will use the 6…
We improved a previously proposed method of using closed-orbit modulation for linear optics correction. Instead of fitting individual closed orbits, the improved method decomposes the orbit oscillation data into two orthogonal modes and…
The current generation of ground-based coronagraphic instruments uses deformable mirrors to correct for phase errors and to improve contrast levels at small angular separations. Improving these techniques, several space and ground based…
Multifocal plane microscopy (MUM) allows three dimensional objects to be imaged in a single camera frame. Our approach uses dual orthogonal diffraction phase gratings with a quadratic distortion of the lines to apply defocus to the first…
The aberrations in an optical microscope are commonly measured and corrected at one location in the field of view, within the so-called isoplanatic patch. Full-field correction is desirable for high-resolution imaging of large specimens.…
We present a method to calibrate a high-resolution wavefront-correcting device with a single, static camera, located in the focal plane; no moving of any component is needed. The method is based on a localized diversity and differential…
The imaging performance of an optical microscope can be degraded by sample-induced aberrations. A general strategy to undo the effect of these aberrations is to apply wavefront correction with a deformable mirror (DM). In most cases, the DM…