Related papers: Gaseous Detectors: recent developments and applica…
Multiwire and microstrip porous detectors have been developed and investigated for DC operation. The multiwire porous detector consists of anode wires, an Al cathode and a gap between them filled with porous CsI. The microstrip porous…
MITPC is a gas-based time projection chamber used for detecting fast, MeV-scale neutrons. The standard version of the detector relies on a mixture of 600~torr gas composed of 87.5% $^4$He and 12.5% CF$_4$ for precisely measuring the energy…
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…
For the International Large Detector (ILD), foreseen to be built at the International Linear Collider (ILC), a Time Projection Chamber (TPC) is intended to be used as the main tracking detector. The amplification will be provided by Micro…
Gaseous detectors have long been used by particle physics experiments at beamlines or standalone experiments. Recently, their low momentum threshold has made them interesting as active targets for long baseline neutrino experiments. To…
Future high-energy physics experiments require a paradigm shift in radiation detector design. In response to this challenge, resistive LGADs that combine Low Gain Avalanche Diode technology with resistive readout have been developed. The…
The aim of the presented work is the development of single-stage amplification resistive Micro Pattern Gas Detectors (MPGD) based on Micromegas technology with the following characteristics: ability to efficiently operate up to 10…
For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro-Pattern Gaseous…
Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…
For identification and 3D-tracking of low-energy electrons a new type of gas-based detector was designed that minimizes scattering and energy loss. The current version of the detector is a combination of a plastic scintillator, serving as a…
Particle IDentification (PID) is a central requirement of the experiments at the future EIC. Hadron PID at high momenta by RICH techniques requires the use of low density gaseous radiators, where the challenge is the limited length of the…
The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade in 2016. Four new photon detectors, based on MPGD technology and covering a total active area larger than 1.2~$m^2$ have replaced the previously…
A GAGG detector capable of dissecting a multi-coincidence solar neutrino interaction on ${}^{71}$Ga is under development for potential space-based applications. We identify three distinct detection signatures when ${}^{71}$Ge$^*$ is…
In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and…
The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a…
Micromegas is presently in use by many experiments providing enhanced performance when used in high particle environment. Compared with other solid-state detectors or conventional gas counters Micromegas is robust and radiation hard. Recent…
For the first time we have fabricated a high granularity micropattern solid-state detector (MSSD) with the unipolar time-differential property for ultrafast pulse response. Optical, x-ray, and gamma-ray photoconductivity measurements prove…
Due to the Helium-3 crisis, alternatives to the standard neutron detection techniques are becoming urgent. In addition, the instruments of the European Spallation Source (ESS) require advances in the state of the art of neutron detection.…
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new…