Related papers: Cross-calibrating X-ray detectors with clusters of…
We extend a previous cross-calibration study by the International Astronomical Consortium for High Energy Calibration (IACHEC) on XMM-Newton/EPIC, Chandra/ACIS and BeppoSAX/MECS X-ray instruments with clusters of galaxies to Suzaku/XIS…
Cosmological constraints from clusters rely on accurate gravitational mass estimates, which strongly depend on cluster gas temperature measurements. Therefore, systematic calibration differences may result in biased, instrument-dependent…
We applied a scientific approach to the problem of the effective area cross-calibration of the XMM-Newton EPIC instruments. Using a sample of galaxy clusters observed with the XMM-Newton EPIC, we quantified the effective area…
Galaxy cluster gas temperatures ($T$) play a crucial role in many cosmological and astrophysical studies. However, it has been shown that $T$ measurements can vary between different X-ray telescopes. These $T$ biases can propagate to…
On behalf of the International Astronomical Consortium for High Energy Calibration (IACHEC), we present results from the cross-calibration campaigns in 2012 on 3C 273 and in 2013 on PKS 2155-304 between the then active X-ray observatories…
The use of galaxy clusters to constrain cosmology is limited in part due to uncertainties in derived cluster masses, which often depend on the gas temperature. Unfortunately, there exists a longstanding discrepancy in temperature…
We aim to examine the relative cross-calibration accuracy of the on-axis effective areas of the XMM-Newton EPIC pn and MOS instruments. Spectra from a sample of 46 bright, high-count, non-piled-up isolated on-axis point sources are stacked…
We present results on the spectroscopic analysis of XMM-Newton EPIC data of the central 0.5/h_50 Mpc regions of the clusters of galaxies Coma, A1795 and A3112. The temperature of the hot intracluster gas as determined by modeling the 2 - 7…
The mass of galaxy clusters can be inferred from the temperature of their X-ray emitting gas, $T_{\mathrm{X}}$. Their masses may be underestimated if it is assumed that the gas is in hydrostatic equilibrium, by an amount…
(Abridged) Spectral and time variability analysis of the region of the hard X-ray transient EXS 1737.9-2952 near the Galactic Centre (GC), using data from the Narrow Field Instruments of BeppoSAX is reported. The main results are the MECS…
This paper presents a ``man on the street'' view of the current status of the spectral cross calibration between the XMM-Newton EPIC, Chandra ACIS-S3, ASCA SIS and GIS, and ROSAT PSPC instruments. Using publicly released software for the…
We analyze four XMM-Newton galaxy clusters in order to test whether their soft X-ray excess emission in the 0.2-0.5 keV band as reported by Kaastra et al. (2003) maintains after the application of the current knowledge of the XMM-Newton…
We explore the band dependence of the inferred X-ray temperature of the intracluster medium (ICM) for 192 well-observed galaxy clusters selected from the Chandra Data Archive. If the hot ICM is nearly isothermal in the projected region of…
We study the X-ray emission in a sample of galaxy clusters using the BeppoSAX PDS instrument in the 20 -- 80 keV energy band. The non-thermal hard X-ray cluster emission (HXR) is detected at a 2 sigma level in 50% of the non-significantly…
We propose a new Monte Carlo method to study extended X-ray sources with the European Photon Imaging Camera (EPIC) aboard {\sl XMM-Newton}. The smoothed particle inference (SPI) technique, described in a companion paper, is applied here to…
We present results of X-ray observations of the Coma cluster with multiple instruments over a broad energy band. Using the data from INTEGRAL, RXTE and ROSAT observatories, we find that the Coma spectrum in the 0.5-107 keV energy band can…
We present new Chandra X-ray observations of the luminous X-ray cluster, MS0451.6-0305, at z=0.5386. Spectral imaging data for the cluster are consistent with an isothermal cluster of 10.0 - 10.6 +/-1.6 keV and an Fe abundance of 0.32-0.40…
The initial results from XMM-Newton observations of the rich cluster of galaxies Abell 1795 are presented. The spatially-resolved X-ray spectra taken by the European Photon Imaging Cameras (EPIC) show a temperature drop at a radius of $\sim…
We report the observation of the Intra-Cluster Medium (ICM) of Abell 85 by the X-ray satellite BeppoSAX. We have both analysed the spectrum obtained in the central 8 arcmin circular region centred on the Very Steep Spectrum Radio Source…
We summarize the outcome of the 10th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held in Beijing (People's Republic of China) in April 2015. Over 80 scientists directly involved in the…