Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the likelihood of rigid…

Image and Video Processing · Electrical Eng. & Systems 2019-12-02 Alexander Preuhs , Michael Manhart , Philipp Roser , Bernhard Stimpel , Christopher Syben , Marios Psychogios , Markus Kowarschik , Andreas Maier

Cone Beam Computed Tomography (CBCT) is widely used in medical imaging. However, the limited number and intensity of X-ray projections make reconstruction an ill-posed problem with severe artifacts. NeRF-based methods have achieved great…

Image and Video Processing · Electrical Eng. & Systems 2025-06-25 Zhuowei Xu , Han Li , Dai Sun , Zhicheng Li , Yujia Li , Qingpeng Kong , Zhiwei Cheng , Nassir Navab , S. Kevin Zhou

In this work, we propose a new paradigm of iterative model-based reconstruction algorithms for providing real-time solution for zooming-in and refining a region of interest in medical and clinical tomographic images. This algorithmic…

Image and Video Processing · Electrical Eng. & Systems 2025-12-01 Junqi Tang , Guixian Xu , Jinglai Li

Reconstruction of few-view x-ray Computed Tomography (CT) data is a highly ill-posed problem. It is often used in applications that require low radiation dose in clinical CT, rapid industrial scanning, or fixed-gantry CT. Existing analytic…

Image and Video Processing · Electrical Eng. & Systems 2019-10-15 Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley

Cone Beam Computed Tomography(CBCT) is a now known method to conduct CT imaging. Especially, The Low Dose CT imaging is one of possible options to protect organs of patients when conducting CT imaging. Therefore Low Dose CT imaging can be…

Computer Vision and Pattern Recognition · Computer Science 2021-04-05 Wooram Kang , Mayank Patwari

Cone-Beam Computed Tomography (CBCT) is an indispensable technique in medical imaging, yet the associated radiation exposure raises concerns in clinical practice. To mitigate these risks, sparse-view reconstruction has emerged as an…

Image and Video Processing · Electrical Eng. & Systems 2024-07-09 Yiqun Lin , Hualiang Wang , Jixiang Chen , Xiaomeng Li

Abstract Objective. Cone-beam computed tomography is becoming more and more popular in applications such as 3D dental imaging. Iterative methods compared to the standard Feldkamp algorithm have shown improvements in image quality of…

Signal Processing · Electrical Eng. & Systems 2024-11-15 Louise Friot-Giroux , Françoise Peyrin , Voichita Maxim

Simulation of x-ray projection images plays an important role in cone beam CT (CBCT) related research projects. A projection image contains primary signal, scatter signal, and noise. It is computationally demanding to perform accurate and…

Medical Physics · Physics 2015-06-04 Xun Jia , Hao Yan , Laura Cervino , Michael Folkerts , Steve B. Jiang

Recently, a number of approaches to low-dose computed tomography (CT) have been developed and deployed in commercialized CT scanners. Tube current reduction is perhaps the most actively explored technology with advanced image reconstruction…

Medical Physics · Physics 2018-09-05 Hoyeon Lee , Jongha Lee , Hyeongseok Kim , Byungchul Cho , Seungryong Cho

Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…

Computed tomography (CT) uses X-ray measurements taken from sensors around the body to generate tomographic images of the human body. Conventional reconstruction algorithms can be used if the X-ray data are adequately sampled and of high…

Image and Video Processing · Electrical Eng. & Systems 2021-12-28 Ruiwen Xing , Thomas Humphries , Dong Si

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with…

Medical Physics · Physics 2025-01-09 Yabo Fu , Hao Zhang , Weixing Cai , Huiqiao Xie , Licheng Kuo , Laura Cervino , Jean Moran , Xiang Li , Tianfang Li

In radiation therapy (RT), the reliance on pre-treatment computed tomography (CT) images encounter challenges due to anatomical changes, necessitating adaptive planning. Daily cone-beam CT (CBCT) imaging, pivotal for therapy adjustment,…

Computer Vision and Pattern Recognition · Computer Science 2024-09-20 Joonil Hwang , Sangjoon Park , NaHyeon Park , Seungryong Cho , Jin Sung Kim

Circular cone-beam (CCB) Computed Tomography (CT) has become an integral part of industrial quality control, materials science and medical imaging. The need to acquire and process each scan in a short time naturally leads to trade-offs…

Image and Video Processing · Electrical Eng. & Systems 2020-10-02 Marinus J. Lagerwerf , Daniel M Pelt , Willem Jan Palenstijn , K Joost Batenburg

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy (IGRT). It provides real time visualization at low cost and dose. However, photon scattering and beam hindrance cause artifacts in CBCT. These include…

Medical Physics · Physics 2025-09-29 Alzahra Altalib , Chunhui Li , Alessandro Perelli

To shorten the door-to-puncture time for better treating patients with acute ischemic stroke, it is highly desired to obtain quantitative cerebral perfusion images using C-arm cone-beam computed tomography (CBCT) equipped in the…

Image and Video Processing · Electrical Eng. & Systems 2024-12-30 Haotian Zhao , Ruifeng Chen , Jing Yan , Juan Feng , Jun Xiang , Yang Chen , Dong Liang , Yinsheng Li

Cone Beam Computed Tomography (CBCT) plays a vital role in clinical imaging. Traditional methods typically require hundreds of 2D X-ray projections to reconstruct a high-quality 3D CBCT image, leading to considerable radiation exposure.…

Image and Video Processing · Electrical Eng. & Systems 2024-10-08 Zhentao Liu , Yu Fang , Changjian Li , Han Wu , Yuan Liu , Dinggang Shen , Zhiming Cui

Scatter can account for large errors in cone-beam CT (CBCT) due to its wide field of view, and its complicated nature makes its compensation difficult. Iterative polyenergetic reconstruction algorithms offer the potential to provide…

Medical Physics · Physics 2020-01-13 Jonathan H. Mason , Alessandro Perelli , William H. Nailon , Mike E. Davies

This work is concerned with applying iterative image reconstruction, based on constrained total-variation minimization, to low-intensity X-ray CT systems that have a high sampling rate. Such systems pose a challenge for iterative image…

Medical Physics · Physics 2016-11-17 Emil Y. Sidky , Rick Chartrand , Yuval Duchin , Christer Ullberg , Xiaochuan Pan

High radiation dose in computed tomography (CT) scans increases the lifetime risk of cancer, which become a major clinical concern. The backprojection-filtration (BPF) algorithm could reduce radiation dose by reconstructing images from…

Medical Physics · Physics 2013-11-20 Yan Bin , Deng Lin , Han Yu , Zhang Feng , Wang Xian Chao , Li Lei