Related papers: Pulse-Shape Discrimination of CaF2(Eu)
Density fluctuations in the ionised interstellar medium have a profound effect on radio pulsar observations, through angular scattering, intensity scintillations, and small changes in time delays from dispersion. Here we show that it is…
We investigate the limitations arising from atomic collisions on the storage and delay times of probe pulses in EIT experiments. We find that the atomic collisions can be described by an effective decay rate that limits storage and delay…
A novel method was developed for the extraction of short emission times of light particles from the projectile-like fragments in peripheral deep-inelastic collisions in the Fermi energy domain. We have taken an advantage of the fact that in…
The radioactive contamination of a BaF$_2$ scintillation crystal with mass of 1.714 kg was measured over 101 hours in the low-background DAMA/R&D set-up deep underground (3600 m w.e.) at the Gran Sasso National Laboratories of INFN (LNGS,…
We report the first measurement of discrimination between low-energy helium recoils and electron recoils in liquid xenon. This result is relevant to proposed low-mass dark matter searches which seek to dissolve light target nuclei in the…
The dependence on applied electric field ($0 - 40$ kV/cm) of the scintillation light produced by fast electrons and $\alpha$ particles stopped in liquid helium in the temperature range of 0.44 K to 3.12 K is reported. For both types of…
We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass…
Electronically excited atoms or molecules may deexcite by emission of a secondary electron through an Auger-Meitner decay. This deexcitation process is typically considered to be exponential in time. This is strictly speaking, however, only…
We present new measurements of the scintillation and ionization yields in liquid xenon for low energy electronic (about 3--7 keV$_{ee}$) and nuclear recoils (about 8--20 keV$_{nr}$) at different drift fields from 236 V/cm to 3.93 kV/cm,…
We present the responses of a NaI(Tl) crystal in terms of the light yield and pulse shape characteristics of nuclear recoil events at two different temperatures: 22 C (room temperature) and -35 C (low temperature). The light yield is…
We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber…
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two…
We report an absolute energy response function to electronic and nuclear recoils for germanium and liquid xenon detectors. As a result, we show that the detection energy threshold of nuclear recoils for a dual-phase xenon detector can be a…
We report on the response of a high light-output NaI(Tl) crystal to nuclear recoils induced by neutrons from an Am-Be source and compare the results with the response to electron recoils produced by Compton scattered 662 keV $\gamma$-rays…
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to…
Copper (Cu), gold (Au) (111) crystals were illuminated with 120 fs pulses and probed by 600 fs X-ray pulses. Rocking curves were measured versus 267 nm (UV) pump- 0.154 nm probe delay time. Curve width broadening, peak diffracted intensity…
Progress in neutron decay experiments requires better methods for the characterization of electron detectors. I show that for such \b{eta}-decay studies, electron time-of-flight can be used for in-situ calibration of electron detectors.…
In the framework of the ``ULTIMA'' project, we use ultra cold superfluid 3He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after…
The SNO+ liquid scintillator experiment is under construction in the SNOLAB facility in Canada. The success of this experiment relies upon accurate characterization of the liquid scintillator, linear alkylbenzene (LAB). In this paper,…
In the field of chemistry, where nuclear motion has traditionally been a focal point, we now explore the ultra-rapid electronic motion spanning attoseconds to femtoseconds, demonstrating that it is equally integral and relevant to the…