Related papers: X-ray analog pixel array detector for single synch…
We present design and realization of an ultra-broadband optical spectrometer capable of measuring the spectral intensity of multi-octave-spanning light sources on a single-pulse basis with a dynamic range of up to 8 orders of magnitude. The…
A facility for sub-nanosecond time-resolved (pump-probe) infrared spectroscopy has been developed at the National Synchrotron Light Source of Brookhaven National Laboratory. A mode-locked Ti:sapphire laser produces 2 ps duration, tunable…
The operation of an inverse-Compton scattering source of x-rays or gamma-rays requires the precision alignment and synchronization of highly focused electron bunches and laser pulses at the collision point. The arrival times of electron and…
Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…
Single photon detection and timing gathered increasing interest in the last few years due to both its necessity in the field of quantum sensing and the advantages of single quanta detection in the field of low level light imaging. While…
Sub-angstrom spatial resolution of electron density coupled with sub-femtosecond temporal resolution is required to directly observe the dynamics of the electronic structure of a molecule after photoinitiation or some other ultrafast…
One-time readout temporal ghost imaging is attempted by utilizing optoelectronic devices that are not originally intended for signal photon detection purposes and as such slow by design. A visible light-emitting diode having a response time…
Pulse trains emitted from dual-comb systems are designed to have low relative timing jitter, making them useful for many optical measurement techniques such as optical ranging and spectroscopy. However, the characterization of low-jitter…
The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to…
The M\"ONCH hybrid pixel detector, with a 25 \textmu m pixel pitch and fast charge-integrating readout, has demonstrated subpixel resolution capabilities for X-ray imaging and deep learning-based electron localization in electron…
A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…
We design and experimentally characterize a balanced homodyne detector optimized for high-repetition-rate (100 MHz) pulsed optical sources. Unlike conventional transimpedance-amplifier architectures, which suffer from nonlinearities and…
Several charge integrating CMOS pixel front-ends utilizing charge removal techniques have been fabricated to extend dynamic range for x-ray diffraction applications at synchrotron sources and x-ray free electron lasers (XFELs). The pixels…
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of…
Data center interconnects (DCIs) will have to support throughputs of 400 Gbps or more per wavelength in the near future. To achieve such high data rates, coherent modulation and detection is used, which conventionally requires high-speed…
The hybrid pixel detector Timepix3 allows the measurement of the time and energy deposition of an event simultaneously in each 55 $\mu$m pixel, which makes Timepix3 a promising approach for a compact Compton camera. However, the angular…
A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to…
Novel event-based electron detector platforms provide an avenue to extend the temporal resolution of electron microscopy into the ultrafast domain. Here, we characterize the timing accuracy of a detector based on a TimePix3 architecture…
In contrast with imaging using position-resolving cameras, single-pixel imaging uses a bucket detector along with spatially structured illumination for image recovery. This emerging imaging technique is a promising candidate for a broad…
An array of compound refractive X-ray lenses (CRL) with 20x20 lenslets, a focal distance of 20 cm and a visibility of 0.93 is presented. It can be used as a Shack-Hartmann sensor for hard X-rays (SHARX) for wavefront sensing and permits for…