Related papers: Test Beam Results Using an RPC Semi-Digital HCAL
A novel charged particle tracking device, a high precision time projection chamber with gas electron multiplier and pad readout, is a leading candidate as the central tracker for an experiment at the International Linear Collider. To…
We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property…
The CALICE collaboration has constructed a highly granular hadronic sampling calorimeter prototype with small scintillator tiles individually read out by silicon photomultipliers (SiPM) to evaluate technologies for the ILC. The imaging…
A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…
The CALICE analog HCAL is a highly granular calorimeter, proposed for the International Linear Collider. It is based on scintillator tiles, read out by silicon photomultipliers (SiPMs). The effects of gaps between the calorimeter tiles, as…
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial…
The CALICE collaboration is developing highly granular calorimeters for experiments at a future lepton collider primarily to establish technologies for particle flow event reconstruction. These technologies also find applications elsewhere,…
A large volume Time Projection Chamber (TPC) has been proposed as main tracking device at the International Linear Collider (ILC). Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…
The CMS Resistive Plate Chamber (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to a factor five more than the…
A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an…
For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro-Pattern Gaseous…
The Resistive Plate Chambers (RPC) are low-cost charged-particle detectors with good timing resolution and potentially good spatial resolution. Using RPC as gamma detector provides an opportunity for application in positron emission…
In this article, we describe the key features of the recently completed technical design for the International Linear Collider (ILC), a 200-500 GeV linear electron-positron collider (expandable to 1 TeV) that is based on 1.3 GHz…
The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…
The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…
We report on several versions of the calibration and monitoring system dedicated to scintillator tile calorimeters built within the CALICE collaboration and intended for future linear collider experiments. Whereas the first, a 1 m3 analogue…
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section…
A novel concept for position-sensitive thermal neutron detectors based on thin-gap Resistive Plate Chambers (RPC) lined with a neutron converter layer is presented and its feasibility is discussed. Several detector architectures…