Related papers: R&D Status and Plan for FPCCD VTX
Pixel Detectors, as the current technology of choice for the innermost vertex detection, have reached a stage at which large detectors have been built for the LHC experiments and a new era of developments, both for hybrid and for monolithic…
This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…
Purpose: CMOS pixel sensors have become extremely attractive for future high performance tracking devices. Initial R\&D work has been conducted for the vertex detector for the proposed Circular Electron Positron Collider that will allow…
Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders requires the use of time information in tracking, due to the increasing levels…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The capacitance of the charge collection node of a sensor system is an important parameter for the design of the analog front-end electronics. The analog front-end of high-granularity sensors like for example hybrid pixel detectors need to…
The physics goals at the future e+e- linear collider require high performance vertexing and impact parameter resolution. Two possible technologies for the vertex detector of an experimental apparatus are outlined in the paper: an evolution…
The Linear Collider Flavour Identification (LCFI) collaboration studies CCD detectors for quark flavour identification in the framework of a future linear e+e- collider. The flavour identification is based on precision reconstruction of…
The DEPFET Collaboration pursues the development of a high resolution pixel vertex detector for future colliders (like ILC), based on the integration of amplifying transistors into a fully depleted bulk. In August 2008, six DEPFET…
The concept of capacitive coupling between sensors and readout chips is under study for the vertex detector at the proposed high-energy CLIC electron positron collider. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is an active…
Being accurate, efficient, and compact is essential to a facial landmark detector for practical use. To simultaneously consider the three concerns, this paper investigates a neat model with promising detection accuracy under wild…
In the construction of High-Luminosity Large Hadron Collider (HL-LHC) and Future Circular Collider (FCC) experiments, 3D pixel sensors have become indispensable components due to their superior radiation hardness, fast response, and low…
The pixel detector is the innermost tracking device in CMS, reconstructing interaction vertices and charged particle trajectories. The sensors located in the innermost layers of the pixel detector must be upgraded for the ten-fold increase…
The e+e- linear collider physics programme sets highly demanding requirements on the accurate determination of charged particle trajectories close to their production point. A new generation of Vertex Trackers, based on different…
Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of…
Two finely segmented and very compact calorimeters are foreseen for the instrumentation of the very forward region of the ILC and the CLIC detectors; a luminometer to measure the rate of low angle Bhabha scattering events with a precision…
We describe the commissioning of a system which has been built to investigate optimal operation of CCDs for the LSST telescope. The test system is designed for low vibration, high stability operation and is capable of illuminating a…
We present a readout chip prototype for future pixel detectors with timing capabilities. The prototype is intended for characterizing 4D pixel arrays with a pixel size of $100\times100~\mu \text{m}^2$, where the sensors are Low Gain…
Results of detailed simulations of the charge transfer inefficiency of a prototype CCD chip are reported. The effect of radiation damage in a particle detector operating at a future accelerator is studied by examining two electron trap…
The High Luminosity upgrade of the CERN Large Hadron Collider will be able to reach a peak instantaneous luminosity of 5E34/cm2 s. The innermost detectors of the CMS and ATLAS experiments will have to cope with unprecedented requirements on…