Related papers: Cyclinac Medical Accelerators Using Pulsed C6+/H2+…
The main `bottleneck' limiting the beam power in circular machines is caused by space charge effects that produce beam instabilities. To increase maximally the beam power of a `proton driver', it is proposed to build a facility consisting…
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving…
In proton therapy, depth scanning of the irradiated object is performed by changing the Output Energy (OE) of the accelerated beam. In pulsed linear accelerators, adjustment of the OE is usually by changing the amplitude and/or phase of the…
The HICAT project is a Heavy Ion accelerator for light ion Cancer Treatment to be built for the clinics in Heidelberg, Germany. It consists of a 7 MeV/u linac, a compact synchrotron and three treatment places, one of them equipped with a…
The construction of the initial part of a normally conducting linac for hydrogen ion beams with a pulsed current of ~20 mA up to an energy of ~70 MeV is considered. The RFQ at a frequency of ~160 MHz accelerates ions to an energy of ~4 MeV.…
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current…
We present experimental studies on ion acceleration from ultra-thin diamond-like carbon (DLC) foils irradiated by ultra-high contrast laser pulses of energy 0.7 J focussed to peak intensities of 5*10^{19} W/cm^2. A reduction in electron…
The conception of High Power Linac developed in Russian accelerator centres is based on the use of independently phased SC resonators with quadrupole lenses between them. The type and parameters of the resonators as well as focusing…
Laser acceleration promises innovation in particle beam therapy of cancer where an ultra-compact accelerator system for cancer beam therapy can become affordable to a broad range of patients. This is not feasible without the introduction of…
The two-frequency heating technique was studied to increase the beam intensities of highly charged ions provided by the high-voltage extraction configuration (HEC) ion source at the National Institute of Radiological Sciences (NIRS). The…
The Pohang Accelerator Laboratory operates an electron linac for the pulsed neutron source as one of the long-term nuclear R&D programs at the Korea Atomic Energy Research Institute. The designed beam parameters are as follows; The nominal…
The `Laser-hybrid Accelerator for Radiobiological Applications', LhARA, is conceived as a novel, uniquely-flexible facility dedicated to the study of radiobiology. The technologies demonstrated in LhARA, which have wide application, will be…
Ion sources are key components of accelerators devoted to different types of medical applications: hadron-therapy facilities (accelerating protons or carbon ions), high-intensity accelerators for boron-neutron capture therapy (using intense…
The Large Hadron electron Collider (LHeC) is a proposed future particle-physics project colliding 60 GeV electrons from a six-pass recirculating energy-recovery Linac (ERL) with 7 TeV protons stored in the LHC. The ERL technology allows for…
The article considers an opportunity of simultaneous pulsed acceleration of seven proton beams with current one hundred milliamps in each beam. The accelerator consists of two parts. In the first part of the accelerator having the length…
Using H2+ ions is expected to mitigate the two major impediments to accelerating very high currents in cyclotrons, due to lower space charge at injection, and stripping extraction. Planning for peak currents of 10 particle milliamps at 800…
An S-band linear accelerator is the source of particles and the front end of the Advanced Photon Source injector. In addition, it supports a low-energy undulator test line (LEUTL) and drives a free-electron laser (FEL). A…
Purpose: In this study, procedures were developed to achieve efficient reversible conversion of a clinical linear accelerator (LINAC) and deliver electron FLASH (eFLASH) or conventional beams to the treatment room isocenter. Material &…
We present a Circular Energy Recovery Collider (CERC) as an alternative approach for a high-energy high-luminosity electron-positron collider to current designs for high-energy electron-positron colliders either based on two storage rings…
A possible solution to realize a conventional positron source driven by a several-GeV electron beam for the International Linear Collider is proposed. A 300 Hz electron linac is employed to create positrons with stretching pulse length in…