Results of a search for Kr-78 double K-capture at the second stage of the experiment with high-pressure copper proportional counters are presented. The method is based on comparison of spectra measured with natural and enriched krypton. The…

The results of the experiment searching for 2K-capture with large low-background proportional counter are presented. The comparison of spectra of the background of the proportional counter filled with Kr enriched in $^{78}$Kr (8400 hr) and…

A pulse shape analysis algorithm and a method for suppressing the noise component of signals from a large copper proportional counter in the experiment aimed at searching for 2K capture of Kr-78 are described. These signals correspond to a…

Instrumentation and Detectors · Physics 2014-11-20 Yu. M. Gavriljuk , A. M. Gangapshev , V. V. Kazalov , V. V. Kuzminov , S. I. Panasenko , S. S. Ratkevich , S. P. Yakimenko

Features of data accumulated at 1817 hours in the experimental search for 2K(2 \nu)-capture decay mode of Kr-78 are discussed. The new limit for this decay half-life is found to be T_{1/2} > 2.3 *10^{20} yr. (90% C.L.).

Nuclear Experiment · Physics 2009-10-31 Ju. M. Gavriljuk , V. V. Kuzminov , N. Ya. Osetrova , S. S. Ratkevich

The results of the experimental search for two-neutrino $2K$-capture in $^{124}$Xe with a large copper proportional counter obtained by processing the data for an exposure of 37.7 kg$\times$day are presented. The experimental setup is…

A technique to search for 2K-capture of $^{78}$Kr with large low-background proportional counter filled with an enriched in $^{78}$Kr up to 99.8% sample of Krypton at a pressure of 4.51 is described in this paper. The results of first…

The results of a search for two neutrino mode of double K-capture of Xe-124 using a large copper low-background proportional counter are presented. Data collected during 3220 hours of measurements with 58.6 g of $^{124}$Xe provides us to a…

First result of experiment for searching of 2K-capture of Xe-124 with the large-volume copper proportional counter is given. The 12 litre sample with 63.3% (44 g) of Xe-124 was used in measurements. The limit on the half-life of Xe-124 with…

The broad physics reach of the LUX-ZEPLIN (LZ) experiment covers rare phenomena beyond the direct detection of dark matter. We report precise measurements of the extremely rare decay of $^{124}$Xe through the process of two-neutrino double…

Nuclear Experiment · Physics 2024-12-10 J. Aalbers , D. S. Akerib , A. K. Al Musalhi , F. Alder , C. S. Amarasinghe , A. Ames , T. J. Anderson , N. Angelides , H. M. Araújo , J. E. Armstrong , M. Arthurs , A. Baker , S. Balashov , J. Bang , J. W. Bargemann , E. E. Barillier , K. Beattie , A. Bhatti , A. Biekert , T. P. Biesiadzinski , H. J. Birch , E. Bishop , G. M. Blockinger , B. Boxer , C. A. J. Brew , P. Brás , S. Burdin , M. Buuck , M. C. Carmona-Benitez , M. Carter , A. Chawla , H. Chen , Y. T. Chin , N. I. Chott , M. V. Converse , R. Coronel , A. Cottle , G. Cox , D. Curran , C. E. Dahl , A. David , J. Delgaudio , S. Dey , L. de Viveiros , L. Di Felice , C. Ding , J. E. Y. Dobson , E. Druszkiewicz , S. Dubey , S. R. Eriksen , A. Fan , N. M. Fearon , N. Fieldhouse , S. Fiorucci , H. Flaecher , E. D. Fraser , T. M. A. Fruth , R. J. Gaitskell , A. Geffre , J. Genovesi , C. Ghag , R. Gibbons , S. Gokhale , J. Green , M. G. D. van der Grinten , J. J. Haiston , C. R. Hall , S. Han , E. Hartigan-O'Connor , S. J. Haselschwardt , M. A. Hernandez , S. A. Hertel , G. Heuermann , G. J. Homenides , M. Horn , D. Q. Huang , D. Hunt , E. Jacquet , R. S. James , J. Johnson , A. C. Kaboth , A. C. Kamaha , M. Kannichankandy , D. Khaitan , A. Khazov , I. Khurana , J. Kim , Y. D. Kim , J. Kingston , R. Kirk , D. Kodroff , L. Korley , E. V. Korolkova , H. Kraus , S. Kravitz , L. Kreczko , V. A. Kudryavtsev , D. S. Leonard , K. T. Lesko , C. Levy , J. Lin , A. Lindote , W. H. Lippincott , M. I. Lopes , W. Lorenzon , C. Lu , S. Luitz , P. A. Majewski , A. Manalaysay , R. L. Mannino , C. Maupin , M. E. McCarthy , G. McDowell , D. N. McKinsey , J. McLaughlin , J. B. McLaughlin , R. McMonigle , E. Mizrachi , A. Monte , M. E. Monzani , E. Morrison , B. J. Mount , M. Murdy , A. St. J. Murphy , A. Naylor , H. N. Nelson , F. Neves , A. Nguyen , C. L. O'Brien , I. Olcina , K. C. Oliver-Mallory , J. Orpwood , K. Y Oyulmaz , K. J. Palladino , J. Palmer , N. J. Pannifer , N. Parveen , S. J. Patton , B. Penning , G. Pereira , E. Perry , T. Pershing , A. Piepke , Y. Qie , J. Reichenbacher , C. A. Rhyne , Q. Riffard , G. R. C. Rischbieter , E. Ritchey , H. S. Riyat , R. Rosero , T. Rushton , D. Rynders , D. Santone , A. B. M. R. Sazzad , R. W. Schnee , G. Sehr , B. Shafer , S. Shaw , T. Shutt , J. J. Silk , C. Silva , G. Sinev , J. Siniscalco , R. Smith , V. N. Solovov , P. Sorensen , J. Soria , A. Stevens , K. Stifter , B. Suerfu , T. J. Sumner , M. Szydagis , D. R. Tiedt , M. Timalsina , Z. Tong , D. R. Tovey , J. Tranter , M. Trask , M. Tripathi , A. Vacheret , A. C. Vaitkus , O. Valentino , V. Velan , A. Wang , J. J. Wang , Y. Wang , J. R. Watson , L. Weeldreyer , T. J. Whitis , K. Wild , M. Williams , W. J. Wisniewski , L. Wolf , F. L. H. Wolfs , S. Woodford , D. Woodward , C. J. Wright , Q. Xia , J. Xu , Y. Xu , M. Yeh , D. Yeum , W. Zha , E. A. Zweig

A scintillation proportional counter with wavelength shifting fiber readout filled with Xe or Kr under a pressure of up to 20 atm is proposed for the low-background experiments on search for dark matter of the Universe and 2K-decay of 78…

Instrumentation and Detectors · Physics 2008-02-03 D. Yu. Akimov , A. A. Burenkov , V. F. Kuzichev , V. L. Morgunov , V. N. Solovov

The ultimate detection limit of optical biosensors is often limited by various noise sources, including those introduced by the optical measurement setup. While sophisticated modifications to instrumentation may reduce noise, a simpler…

Signal Processing · Electrical Eng. & Systems 2021-09-07 Simon J. Ward , Rabeb Layouni , Sofia Arshavsky-Graham , Ester Segal , Sharon M. Weiss

A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro…

A wavelet transform spectrum analyzer operating in real time within the frequency range 3X10^(-5) - 1.3X10^5 Hz has been implemented on a low-cost Digital Signal Processing board operating at 150MHz. The wavelet decomposition of the signal…

Statistical Mechanics · Physics 2009-11-07 Doriano Brogioli , Alberto Vailati

The K2K Long--Baseline neutrino oscillation experiment has been aquiring data since mid-1999 and has analysed those up to March of 2001. Forty-four fully contained events are observedin the fiducial volume of the far detector where…

High Energy Physics - Experiment · Physics 2019-08-14 James E. Hill

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales (~ 1 degree). Between 2008 October and 2010…

A search for various double electron capture modes of $^{74}$Se has been performed using an ultralow background Ge-detector in the Felsenkeller laboratory, Germany. Especially for the potentially resonant transition into the 1204.2 keV…

Nuclear Experiment · Physics 2016-07-20 B. Lehnert , T. Wester , D. Degering , D. Sommer , L. Wagner , K. Zuber

A radiopure cadmium tungstate crystal scintillator, enriched in 106-Cd to 66%, with mass of 216 g (106-CdWO4) was used in coincidence with four ultra-low background HPGe detectors contained in a single cryostat to search for double beta…

During the first half of the K2K run, data corresponding to 4.8x10^19 POT were accumulated. In this data set, 56 accelerator-produced neutrino events were observed in the far detector, while the expected number from the near site…

High Energy Physics - Experiment · Physics 2007-05-23 Takanobu Ishii

We carried out the comparative study of the signal from the decay of double $K$-shell vacancy production that follows after single $K$-shell electron capture of $^{81}$Kr and double $K$-shell electron capture of $^{78}$Kr. The radiative…

We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to…