English
Related papers

Related papers: Model of the response function of large mass bolom…

200 papers

Large-mass bolometers are used in particle physics experiments to search for rare processes. The energy threshold of such detectors plays a critical role in their capability to search for dark matter interactions and rare nuclear decays. We…

Instrumentation and Methods for Astrophysics · Physics 2015-03-17 Sergio Di Domizio , Filippo Orio , Marco Vignati

Bolometric detectors are used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. By operating at cryogenic temperatures, they are able to detect particle…

Instrumentation and Detectors · Physics 2011-09-01 M. Carrettoni , M. Vignati

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters…

Instrumentation and Detectors · Physics 2022-08-01 CUORE Collaboration , D. Q. Adams , C. Alduino , K. Alfonso , F. T. Avignone , O. Azzolini , G. Bari , F. Bellini , G. Benato , M. Beretta , M. Biassoni , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , A. Caminata , A. Campani , L. Canonica , X. G. Cao , S. Capelli , C. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , D. Chiesa , M. Clemenza , S. Copello , O. Cremonesi , R. J. Creswick , A. D'Addabbo , I. Dafinei , F. Del Corso , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , V. Dompè , D. Q. Fang , G. Fantini , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , S. H. Fu , B. K. Fujikawa , S. Ghislandi , A. Giachero , A. Gianvecchio , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , R. G. Huang , H. Z. Huang , J. Johnston , G. Keppel , Yu. G. Kolomensky , R. Kowalski , M. Li , R. Liu , L. Ma , Y. G. Ma , L. Marini , R. H. Maruyama , D. Mayer , Y. Mei , S. Morganti , T. Napolitano , M. Nastasi , J. Nikkel , C. Nones , E. B. Norman , A. Nucciotti , I. Nutini , T. O'Donnell , M. Olmi , J. L. Ouellet , S. Pagan , C. E. Pagliarone , L. Pagnanini , M. Pallavicini , L. Pattavina , M. Pavan , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , C. Rosenfeld , S. Sangiorgio , B. Schmidt , N. D. Scielzo , V. Sharma , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , F. Terranova , C. Tomei , K. J. Vetter , M. Vignati , S. L. Wagaarachchi , B. S. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , S. Zimmermann , S. Zucchelli

In nuclear, particle and astroparticle physics experiments, calorimeters are used to measure the properties of particles with kinetic energies that range from a fraction of 1 eV to 10^20 eV or more. These properties are not necessarily…

Instrumentation and Detectors · Physics 2018-10-17 Richard Wigmans

During the last couple of decades, the use of arrays of bolometers has represented one of the leading techniques for the search for rare events. CUORE, an array of 988 TeO$_2$ bolometers that is taking data since April 2017 at the…

Instrumentation and Detectors · Physics 2018-12-07 S. Di Domizio , A. Branca , A. Caminata , L. Canonica , S. Copello , A. Giachero , E. Guardincerri , L. Marini , M. Pallavicini , M. Vignati

The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale cryogenic experiment designed to search for neutrinoless double-beta decay of $^{130}$Te and other rare events. The CUORE detector consists of 988 TeO$_2$…

Instrumentation and Detectors · Physics 2016-11-24 J. S. Cushman , A. Dally , C. J. Davis , L. Ejzak , D. Lenz , K. E. Lim , K. M. Heeger , R. H. Maruyama , A. Nucciotti , S. Sangiorgio , T. Wise

CUORE will be a 1 ton experiment made of about 1000 TeO$_2$ bolometers. It will probe the neutrinoless double beta decay (0$\nu$DBD) of $^{130}$Te, a tool to test the neutrino nature and mass. The excellent energy resolution and the low…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 M. Vignati

Among the detectors used for rare event searches, such as neutrinoless Double Beta Decay (0$\nu$DBD) and Dark Matter experiments, bolometers are very promising because of their favorable properties (excellent energy resolution, high…

Nuclear Experiment · Physics 2015-06-03 L. Gironi

The CUORE experiment will search for neutrinoless double beta decay (0nDBD) of 130Te using an array of 988 TeO_2 bolometers operated at 10 mK in the Laboratori Nazionali del Gran Sasso (Italy). The detector is housed in a large cryogen-free…

Nuclear Experiment · Physics 2010-01-15 S. Sangiorgio , L. M. Ejzak , K. M. Heeger , R. H. Maruyama , A. Nucciotti , M. Olcese , T. S. Wise , A. L. Woodcraft

CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for…

Instrumentation and Detectors · Physics 2017-12-15 CUORE Collaboration , C. Alduino , K. Alfonso , D. R. Artusa , F. T. Avignone , O. Azzolini , G. Bari , J. W. Beeman , F. Bellini , G. Benato , A. Bersani , M. Biassoni , A. Branca , C. Brofferio , C. Bucci , A. Camacho , A. Caminata , L. Canonica , X. G. Cao , S. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , L. Cassina , D. Chiesa , N. Chott , M. Clemenza , S. Copello , C. Cosmelli , O. Cremonesi , R. J. Creswick , J. S. Cushman , A. D'Addabbo , D. D'Aguanno , I. Dafinei , C. J. Davis , S. Dell'Oro , M. M. Deninno , S. Di Domizio , M. L. Di Vacri , A. Drobizhev , D. Q. Fang , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , B. K. Fujikawa , A. Giachero , L. Gironi , A. Giuliani , L. Gladstone , P. Gorla , C. Gotti , T. D. Gutierrez , E. E. Haller , K. Han , E. Hansen , K. M. Heeger , R. Hennings-Yeomans , H. Z. Huang , R. Kadel , G. Keppel , Yu. G. Kolomensky , A. Leder , C. Ligi , K. E. Lim , Y. G. Ma , M. Maino , L. Marini , M. Martinez , R. H. Maruyama , Y. Mei , N. Moggi , S. Morganti , P. J. Mosteiro , T. Napolitano , M. Nastasi , C. Nones , E. B. Norman , V. Novati , A. Nucciotti , T. O'Donnell , J. L. Ouellet , C. E. Pagliarone , M. Pallavicini , V. Palmieri , L. Pattavina , M. Pavan , G. Pessina , G. Piperno , C. Pira , S. Pirro , S. Pozzi , E. Previtali , C. Rosenfeld , C. Rusconi , M. Sakai , S. Sangiorgio , D. Santone , B. Schmidt , J. Schmidt , N. D. Scielzo , V. Singh , M. Sisti , A. R. Smith , L. Taffarello , F. Terranova , C. Tomei , M. Vignati , S. L. Wagaarachchi , B. S. Wang , H. W. Wang , B. Welliver , J. Wilson , L. A. Winslow , T. Wise , A. Woodcraft , L. Zanotti , G. Q. Zhang , S. Zimmermann , S. Zucchelli

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target…

Instrumentation and Detectors · Physics 2021-12-06 CUORE Collaboration , D. Q. Adams , C. Alduino , F. Alessandria , K. Alfonso , E. Andreotti , F. T. Avignone , O. Azzolini , M. Balata , I. Bandac , T. I. Banks , G. Bari , M. Barucci , J. W. Beeman , F. Bellini , G. Benato , M. Beretta , A. Bersani , D. Biare , M. Biassoni , F. Bragazzi , A. Branca , C. Brofferio , A. Bryant , A. Buccheri , C. Bucci , C. Bulfon , A. Camacho , J. Camilleri , A. Caminata , A. Campani , L. Canonica , X. G. Cao , S. Capelli , M. Capodiferro , L. Cappelli , L. Cardani , M. Cariello , P. Carniti , M. Carrettoni , N. Casali , L. Cassina , E. Celi , R. Cereseto , G. Ceruti , A. Chiarini , D. Chiesa , N. Chott , M. Clemenza , D. Conventi , S. Copello , C. Cosmelli , O. Cremonesi , C. Crescentini , R. J. Creswick , J. S. Cushman , A. D'Addabbo , D. D'Aguanno , I. Dafinei , V. Datskov , C. J. Davis , F. Del Corso , S. Dell'Oro , M. M. Deninno , S. Di Domizio , V. Dompè , M. L. Di Vacri , L. Di Paolo , A. Drobizhev , L. Ejzak , R. Faccini , D. Q. Fang , G. Fantini , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , S. H. Fu , B. K. Fujikawa , R. Gaigher , S. Ghislandi , A. Giachero , L. Gironi , A. Giuliani , L. Gladstone , J. Goett , P. Gorla , C. Gotti , C. Guandalini , M. Guerzoni , M. Guetti , T. D. Gutierrez , E. E. Haller , K. Han , E. V. Hansen , K. M. Heeger , R. Hennings-Yeomans , K. P. Hickerson , R. G. Huang , H. Z. Huang , M. Iannone , L. Ioannucci , J. Johnston , R. Kadel , G. Keppel , L. Kogler , Yu. G. Kolomensky , A. Leder , C. Ligi , K. E. Lim , R. Liu , L. Ma , Y. G. Ma , C. Maiano , M. Maino , L. Marini , M. Martinez , C. Martinez Amaya , R. H. Maruyama , D. Mayer , R. Mazza , Y. Mei , N. Moggi , S. Morganti , P. J. Mosteiro , S. S. Nagorny , T. Napolitano , M. Nastasi , J. Nikkel , S. Nisi , C. Nones , E. B. Norman , V. Novati , A. Nucciotti , I. Nutini , T. O'Donnell , M. Olcese , E. Olivieri , F. Orio , D. Orlandi , J. L. Ouellet , S. Pagan , C. E. Pagliarone , L. Pagnanini , M. Pallavicini , V. Palmieri , L. Pattavina , M. Pavan , M. Pedretti , R. Pedrotta , A. Pelosi , M. Perego , G. Pessina , V. Pettinacci , G. Piperno , C. Pira , S. Pirro , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , F. Reindl , F. Rimondi , L. Risegari , C. Rosenfeld , C. Rossi , C. Rusconi , M. Sakai , E. Sala , C. Salvioni , S. Sangiorgio , D. Santone , D. Schaeffer , B. Schmidt , J. Schmidt , N. D. Scielzo , V. Sharma , V. Singh , M. Sisti , A. R. Smith , D. Speller , F. Stivanello , P. T. Surukuchi , L. Taffarello , L. Tatananni , M. Tenconi , F. Terranova , M. Tessaro , C. Tomei , G. Ventura , K. J. Vetter , M. Vignati , S. L. Wagaarachchi , J. Wallig , B. S. Wang , H. W. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , T. Wise , L. Zanotti , C. Zarra , G. Q. Zhang , B. X. Zhu , S. Zimmermann , S. Zucchelli

Bolometric experiments searching for rare events usually require an extremely low radioactive background to prevent spurious signals from mimicking those of interest, spoiling the sensitivity of the apparatus. In such contexts, radioactive…

Instrumentation and Detectors · Physics 2018-03-28 P. Carniti , L. Cassina , A. Giachero , C. Gotti , G. Pessina

The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest…

Bolometers have proven to be very good detectors to search for rare processes thanks to their excellent energy resolution and their low intrinsic background. Further active background rejection can be obtained by the simultaneous readout of…

The Cryogenic Underground Observatory for Rare Events (CUORE) is a bolometric experiment for neutrinoless double-beta decay in $^{130}$Te search, currently taking data at the underground facility of Laboratori Nazionali del Gran Sasso…

The CALICE collaboration conducts calorimeter R&D for highly granular calorimeters, mainly for their application in detectors for a future lepton collider at the TeV scale. The activities ranges from generic R&D with small devices up to…

Instrumentation and Detectors · Physics 2013-03-12 The CALICE Collaboration

Bolometers are phonon mediated detectors used in particle physics experiments to search for rare processes, such as neutrinoless double beta decay and dark matter interactions. They feature an excellent energy resolution, which is a few keV…

Data Analysis, Statistics and Probability · Physics 2012-06-28 C. Mancini-Terracciano , M. Vignati

We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors…

Nuclear Experiment · Physics 2015-05-20 C. Arnaboldi , C. Brofferio , O. Cremonesi , L. Gironi , M. Pavan , G. Pessina , S. Pirro , E. Previtali

Cryogenic calorimetric detectors are a powerful tool in the search for rare events such as neutrinoless double beta decay ($0\nu\beta \beta$), due to their excellent energy resolution and low intrinsic background. The performance of these…

Instrumentation and Detectors · Physics 2026-05-22 Enzo Brandani , Yael Zayats , Vladyslav Berest , Tong Zhu , Yury Kolomensky
‹ Prev 1 2 3 10 Next ›