Related papers: Silicon photomultiplier timing performance study
A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…
The LHCb experiment at CERN has been upgraded for the Run 3 operation of the Large Hadron Collider (LHC). A new concept of tracking detector based on Scintillating Fibres (SciFi) read out with multichannel silicon photomultipliers (SiPMs)…
The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…
The use of silicon photomultipliers (SiPMs) in imaging atmospheric Cherenkov telescopes is expected to extend the observation times of very-high-energy gamma-ray sources, particularly within the highest energy domain of 50-300 TeV, where…
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $\sigma_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with…
Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large…
Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as…
Silicon Photomultipliers (SiPMs) are state-of-the-art photon detectors used in particle physics, medical imaging, and beyond. They are sensitive to individual photons in the optical wavelength regime and achieve time resolutions of a few…
The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…
The temperature of a nonneutral plasma confined in a Penning-Malmberg trap can be determined by slowly lowering one side of the trap's electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles…
We demonstrate fast counting and multiphoton detection abilities of a Silicon Photo Multiplier (SiPM). In fast counting mode we are able to detect two consecutive photons separated by only 2.3 ns corresponding to 430 MHz. The counting…
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…
Many of the characteristics of Silicon Photomultipliers (SiPMs), such as high Photon Detection Efficiency (PDE), are well matched to the requirements of the cameras of the Small-Sized Telescopes (SSTs) proposed for the Cherenkov Telescope…
The development of detectors using Silicon Photo-Multipliers for acquisition of fast light signals coming from Cherenkov and fluorescence emissions started by particle showers in the terrestrial atmosphere is the main goal of the Italian…
Visible light photon counters (VLPCs) offer many attractive features as photon detectors, such as high quantum efficiency and photon number resolution. We report measurements of the single-photon timing jitter in a VLPC, a critical…
The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and…
We have investigated the effects of X-ray irradiation to doses of 0, 200 Gy, 20 kGy, 2 MGy, and 20 MGy on the Hamamatsu silicon-photomultiplier (SiPM) S10362-11-050C. The SiPMs were irradiated without applied bias voltage. From…
Novel generation of silicon-based photodetectors are attractive alternatives to the traditional phototubes. They offer significant advantages but they present new challenges too. Presence of afterpulses may affect many characteristics of…
We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor…