Related papers: Luminosity Measurement at ILC
This is the first of the series of papers which present a precision method of the day-by-day monitoring of the absolute LHC luminosity. The method is based on the measurement of the rate of coplanar lepton pairs produced in peripheral…
Absolute normalisation of the LHC measurements with O(1%) precision and their relative normalisation, for the data collected at variable centre-of-mass energies, or for variable beam particle species, with O(0.1%) precision is crucial for…
Purpose: Luminosity measurement at the Circular Electron-Positron Collider (CEPC) is required to achieve 10^-4 precision when operating at the center-of-mass energy of the Z-pole. Approximately 10^12 Z-bosons will be collected to refine…
For both the FCC-ee and the ILC, to exploit properly the respective precision physics program, the theoretical precision tag on the respective luminosity will need to be improved from the analogs of the $ 0.054 \% (0.061\%)$ results at LEP…
Future electron-positron ($\ee$) colliders, operating as Higgs factories or Z factories, promise unprecedented precision electroweak measurements that are vital to testing the Standard Model (SM) and exploring physics beyond it. Here we…
The first part of the physics programme of the integrated FCC (Future Circular Colliders) proposal includes measurements of Standard Model processes in $e^+e^-$ collisions (FCC-ee) with an unprecedented precision. In particular, the…
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since…
A precision luminosity measurement is essential for LHC cross-section measurements to determine fundamental parameters of the standard model and constrain or discover beyond-the-standard-model phenomena. The luminosity of the CMS detector…
The possibility to determine the recorded integrated luminosity via the measurements of the W and Z boson production cross-sections with the ATLAS detector is discussed. The current results based on 2010 data are briefly summarized. Special…
Precision luminosity measurements are essential to determine the fundamental properties of the physics processes at the LHC. The estimation of the integrated luminosity at the CMS experiment requires absolute scale calibration of the…
The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…
Based on a paper published in 2019 by the FCAL Collaboration, this talk is giving an update of the Collaboration's effort to design prototype of highly compact calorimeter to instrument the very forward region of a detector at future…
The design luminosity for the future linear colliders is very demanding and challenging. Beam-based feedback systems will be required to achieve the necessary beam-beam stability and steer the two beams into collision. In particular we have…
We study the theoretical accuracy of various methods that have been proposed to measure the luminosity of the LHC pp collider, as well as for Run II of the Tevatron p barp collider. In particular we consider methods based on (i) the total…
In the high luminosity scenario of the LHC (HL-LHC), which will bring the instantaneous luminosity up to 7.5\,$\times$\,$10^{34}$\,cm$^{-2}$s$^{-1}$, ATLAS and CMS will need to operate at up to 200 interactions per 25\,ns beam crossing and…
The LHCb detector optimised its performance in Runs~1 and~2 by stabilising the instantaneous luminosity during a fill. This was achieved by tuning the distance between the two colliding beams according to the measurement of instantaneous…
A precise determination of absolute luminosity, using the bremsstrahlung process, at the future Electron-Ion Collider (EIC) will be very demanding, and its three major challenges are discussed herein. First, the bremsstrahlung rate…
In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the…
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The…
The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These…