Related papers: An improved design of an inductive fault current l…
We present general principles of the parameters calculation and application of two power devices: an inductive fault current limiter and a current-limiting transformer. Both the devices are based on the superconducting - normal state…
Numerous proposed and developed superconducting fault current limiters and self-limiting transformers limit successfully fault currents but do not provide uninterrupted supplying of consumers. A design investigated in the work combines the…
We reveal obstacles related to the application of HTS cylinders in current limiting devices based on the superconducting - normal state transition. It is shown that, at the critical current density achieved presently in bulk materials, and…
For many technological applications of superconductors the performance of a material is determined by the highest current it can carry losslessly - the critical current. In turn, the critical current can be controlled by adding…
The working principle of a electric current transformer is based on electromagnetic induction, mainly composed of a closed iron core and windings. Its primary winding has relatively few turns and is connected in series with the current…
The influence of a superconducting fault current limiter (FCL) on the transient stability of the synchronic operation of electric machines is analyzed for different locations of the inductive FCL in a network and for different parameters of…
A superconducting fault current limiter of the transformer type (inductive FCL) based on magnetic coupling between a superconducting element and a protected circuit has been investigated by many authors for various parameters and…
Short circuit fault currents are increasing due to growing demand for electricity and high complexity in power systems. Because the fault currents reach the highest value which the breakers are unable to restrict, the electrical grid…
This paper outlines reduced-order models for grid-forming virtual-oscillator-controlled inverters with nested current- and voltage-control loops, and current-limiting action for over-current protection. While a variety of model-reduction…
In the past few years there has been a significant rise in the short-circuit current levels in transmission and distribution networks, it due to the increasing demands on power and the addition of sources of distributed generations. It…
The increase of current uniformity along of a resistive type superconductor fault current limiter (R-SFCL) in the design of this type of limiters is well perceived as an important issue. The non-uniform distribution of current in R-SFCL…
Superconducting fault current limiters (SFCLs) are new high-precision and fast-response devices which help to reduce the fault current within the breaking capacity of the protective relays. Nevertheless, the reconfigurable structure of the…
In the last decades, the applications of power inverter increased rapidly. As a result, in spite of rectifier, an inverter with a high-power electronic oscillator has capability to convert direct current (DC) into alternating current (AC)…
We propose that the superconducting diode (SD) efficiency can be significantly enhanced near the transition between two superconducting states by choosing parameters where, before the system goes normal with increasing supercurrent, it…
A planar DC-blocker suitable for differential mode signaling applications is designed and fabricated. The theory of this component is explained in a new form which utilizes the wave scattering transfer matrix. The proposed interpretation of…
The paper deals with the modelling and control of a double winded induction generator. The controlled process is an induction generator with distinct excitation winding. At the generator terminal is connected a load (electrical consumer).…
This article proposes a "cross-forming" control concept for grid-forming inverters operating against grid faults. Cross-forming refers to voltage angle forming and current magnitude forming. It differs from classical grid-forming and…
The possibility of a substantial reduction of weight and size of electrical generators is the main incentive behind the effort to develop superconducting armature windings based on coated conductors in the form of wide tapes with large…
Learning from two-level voltage source converters, the existing impedance-based stability analyses of modular multilevel converters (MMCs) primarily focus on system modes with finite closed-loop transfer functions, which consider…
Experiments on potential differences in the low-temperature vortex solid phase of monocrystalline platelets of superconducting Bi(2)Sr(2)CaCu(2)O(8) (BSCCO) subjected to currents driven either through an "ab" surface or from one such…