English
Related papers

Related papers: GPU-based Fast Cone Beam CT Reconstruction from Un…

200 papers

Cone-Beam Computed Tomography (CBCT) is essential in medical imaging, and the Feldkamp-Davis-Kress (FDK) algorithm is a popular choice for reconstruction due to its efficiency. However, FDK is susceptible to noise and artifacts. While…

Image and Video Processing · Electrical Eng. & Systems 2025-05-21 Yipeng Sun , Linda-Sophie Schneider , Chengze Ye , Mingxuan Gu , Siyuan Mei , Siming Bayer , Andreas Maier

Dynamic cone-beam computed tomography (CBCT) can capture high-spatial-resolution, time-varying images for motion monitoring, patient setup, and adaptive planning of radiotherapy. However, dynamic CBCT reconstruction is an extremely…

Medical Physics · Physics 2023-12-05 Hua-Chieh Shao , Mengke Tielige , Tinsu Pan , You Zhang

Reconstructing 3D cone beam computed tomography (CBCT) images from a limited set of projections is an important inverse problem in many imaging applications from medicine to inertial confinement fusion (ICF). The performance of traditional…

Image and Video Processing · Electrical Eng. & Systems 2025-10-06 Xiaojian Xu , Marc Klasky , Michael T. McCann , Jason Hu , Jeffrey A. Fessler

Cone beam computed tomography (CBCT) images can be used for dose calculation in adaptive radiation therapy (ART). The main challenges are the large artefacts and inaccurate Hounsfield unit (HU) values. Currently, deformed planning CT images…

Medical Physics · Physics 2019-09-04 Xiao Liang , Liyuan Chen , Dan Nguyen , Zhiguo Zhou , Xuejun Gu , Ming Yang , Jing Wang , Steve Jiang

High quality reconstruction with interventional C-arm cone-beam computed tomography (CBCT) requires exact geometry information. If the geometry information is corrupted, e. g., by unexpected patient or system movement, the measured signal…

While Model Based Iterative Reconstruction (MBIR) of CT scans has been shown to have better image quality than Filtered Back Projection (FBP), its use has been limited by its high computational cost. More recently, deep convolutional neural…

Image and Video Processing · Electrical Eng. & Systems 2018-12-21 Amirkoushyar Ziabari , Dong Hye Ye , Somesh Srivastava , Ken D. Sauer , Jean-Baptiste Thibault , Charles A. Bouman

Cone-beam computed tomography (CBCT) is an important tool facilitating computer aided interventions, despite often suffering from artifacts that pose challenges for accurate interpretation. While the degraded image quality can affect…

Image and Video Processing · Electrical Eng. & Systems 2024-07-02 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART)…

The recent application of Fourier Based Iterative Reconstruction Method (FIRM) has made it possible to achieve high-quality 2D images from a fan beam Computed Tomography (CT) scan with a limited number of projections in a fast manner. The…

Image and Video Processing · Electrical Eng. & Systems 2020-06-24 N. Teyfouri , H. Rabbani , R. Kafieh , Iraj Jabbari

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

Medical Physics · Physics 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

Time-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection without phase sorting or binning), is highly desired for regular and irregular motion characterization,…

Medical Physics · Physics 2025-07-28 Jiacheng Xie , Hua-Chieh Shao , You Zhang

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…

Cone-beam X-ray Computed Tomography (XCT) with large detectors and corresponding large-scale 3D reconstruction plays a pivotal role in micron-scale characterization of materials and parts across various industries. In this work, we present…

Computer Vision and Pattern Recognition · Computer Science 2025-01-27 Aniket Pramanik , Obaidullah Rahman , Singanallur V. Venkatakrishnan , Amirkoushyar Ziabari

Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…

Medical Physics · Physics 2016-10-18 Steven Tilley , Wojciech Zbijewski , Jeffrey H. Siewerdsen , J. Webster Stayman

The fastCAT application uses pre-calculated Monte Carlo (MC) CBCT phantom-specific scatter and detector response functions to reduce simulation time for megavoltage (MV) and kilovoltage (kV) CBCT imaging. Pre-calculated x-ray beam energy…

Medical Physics · Physics 2021-09-15 Jericho O'Connell , Magdalena Bazalova-Carter

Obtaining accurate and reliable images from low-dose computed tomography (CT) is challenging. Regression convolutional neural network (CNN) models that are learned from training data are increasingly gaining attention in low-dose CT…

Image and Video Processing · Electrical Eng. & Systems 2019-08-06 Il Yong Chun , Xuehang Zheng , Yong Long , Jeffrey A. Fessler

Computed tomography (CT) is widely used in screening, diagnosis, and image-guided therapy for both clinical and research purposes. Since CT involves ionizing radiation, an overarching thrust of related technical research is development of…

Image and Video Processing · Electrical Eng. & Systems 2019-06-25 Chenyu You , Guang Li , Yi Zhang , Xiaoliu Zhang , Hongming Shan , Shenghong Ju , Zhen Zhao , Zhuiyang Zhang , Wenxiang Cong , Michael W. Vannier , Punam K. Saha , Ge Wang

Proton computed tomography (pCT) is a novel medical imaging modality for mapping the distribution of proton relative stopping power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range…

Four-dimensional cone-beam computed tomography (4D CBCT) provides respiration-resolved images and can be used for image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw…

Image and Video Processing · Electrical Eng. & Systems 2024-10-01 Ziheng Deng , Hua Chen , Yongzheng Zhou , Haibo Hu , Zhiyong Xu , Jiayuan Sun , Tianling Lyu , Yan Xi , Yang Chen , Jun Zhao

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

Image and Video Processing · Electrical Eng. & Systems 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu
‹ Prev 1 3 4 5 6 7 10 Next ›