Related papers: Imaging with high Dynamic using an Ionization Cham…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial…
Detecting light is fundamental to all optical experiments and applications. At the single photon level, the quantised nature of light requires specialised detectors, which typically saturate for more than one photon, rendering the…
A thick gas electron multiplier (THGEM) chamber with an effective readout area of 10$\times$10 cm$^{2}$ and a 11.3 mm ionization gap has been tested along with two regular gas electron multiplier (GEM) chambers in a cosmic ray test system.…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
We present a novel way of wavefront sensing using a commercially available, continuous-wave time-of-flight camera with QVGA-resolution. This CMOS phase camera is capable of sensing externally modulated light sources with frequencies up to…
Ptychographic imaging with soft X-rays, especially in the water window energy range, suffers from limited detector dynamic range that directly influences the maximum spatial resolution achievable. High-dynamic-range data can be obtained by…
A crucial limitation of current high-resolution 3D photoacoustic tomography (PAT) devices that employ sequential scanning is their long acquisition time. In previous work, we demonstrated how to use compressed sensing techniques to improve…
Recent innovations shows that blending of details captured by single Low Dynamic Range (LDR) sensor overcomes the limitations of standard digital cameras to capture details from high dynamic range scene. We present a method to produce…
High speed mid-wave infrared (MWIR) photodetectors have important applications in the emerging areas such high-precision frequency comb spectroscopy and light detection and ranging (LIDAR). In this work, we report a high-speed…
A compact, portable and large field-of-view gamma camera to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities, which allow one to use…
High gradient accelerator injectors have been widely studied throughout the world-leading accelerator facilities. The demand for high frequency cavities have led the Detector, Accelerator and instrumentation laboratory (KAHVELab) in…
A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout…
We describe a method aiming at increasing the dynamic range of X-ray detectors. Two X-ray exposures of an object are acquired at different dose levels and constitute the only input data. The values of the parameters which are needed to…
Photonic sensors based upon high-quality optical microcavities have found a wide variety of applications ranging from inertial sensing, electro- and magnetometry to chemical and biological sensing. These sensors have a dynamic range limited…
The Madison AWAKE Prototype (MAP) is a high-power, high-density helicon plasma experiment. The project's main goal is to develop a scalable plasma source for use in a beam-driven plasma wakefield accelerator as part of the AWAKE project. We…
A possible implementation of the Micro Drift Chamber (MDC) technique as a high resolution vertex detector in the upstream part of the DIRAC spectrometer was investigated in this paper. Simulations of different MDC layout were performed with…
We present recent laboratory results demonstrating high-contrast coronagraphy for the future space-based large IR/Optical/Ultraviolet telescope recommended by the Decadal Survey. The High-contrast Imager for Complex Aperture Telescopes…
We present an approach for in situ dynamic four-dimensional (4D=3D space + 1D time) laser induced strong field ionization tomography, particularly suited for measuring far-from-equilibrium systems, such as supersonic and hypersonic pulsed…
An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our…