Related papers: LFI 30 and 44 GHz receivers Back-End Modules
This paper presents the characterization of the in-flight beams, the beam window functions and the associated uncertainties for the Planck Low Frequency Instrument (LFI). Knowledge of the beam profiles is necessary for determining the…
The Low Frequency Instrument (LFI) of the "Planck Surveyor" ESA mission will perform high-resolution imaging of the Cosmic Microwave Background anisotropies at four frequencies in the 30-100 GHz range. We review the LFI main scientific…
We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44 and 70 GHz. In particular, we…
The Radiometer Electronics Box Assembly (REBA) is the control and data processing on board computer of the Low Frequency Instrument (LFI) of the Planck mission (ESA). The REBA was designed and built incorporating state of the art…
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal…
In-flight measurement of the antenna main beams of the Planck instruments is a crucial input to the data analysis pipeline. We study the main beam reconstruction achievable through external planets using a flight simulator to model their…
The detector readout architecture introduced in this paper is intended for small to medium size physics experiments that have moderate bandwidth needs, and applications that require an ultimately low background radioactivity for the parts…
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz,…
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a…
We report on the development of W-band (75-110 GHz) heterodyne receiver technology for large-format astronomical arrays. The receiver system is designed to be both mass-producible, so that the designs could be scaled to thousands of…
The Planck mission will provide full-sky maps of the Cosmic Microwave Background with unprecedented angular resolution (~ 10') and sensitivity (DT / T = 10^-6). This requires cryogenically cooled, high sensitivity detectors as well as an…
We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The…
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at…
Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for…
LED degradation is usually associated with defects in the active region. Whereby the noise analysis can be a strong instrument to reveal them. The results of optical noise measurements for commercially available blue LED samples in a wide…
We constrain polarized foreground emission between 30 and 70 GHz with the Planck Low Frequency Instrument (LFI) and WMAP data within the global Bayesian BeyondPlanck framework. We combine for the first time full-resolution Planck LFI…
Planar light-emitting diodes (LEDs) fabricated within a single high-mobility quantum well are demonstrated. Our approach leads to a dramatic reduction of radiative lifetime and junction area with respect to conventional vertical LEDs,…
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands…
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature…