English
Related papers

Related papers: Cryogenic environment and performance for testing …

200 papers

"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test…

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221 Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled…

Instrumentation and Methods for Astrophysics · Physics 2010-01-27 G. Morgante , D. Pearson , F. Melot , P. Stassi , L. Terenzi , P. Wilson , B. Hernandez , L. Wade , A. Gregorio , M. Bersanelli , C. Butler , N. Mandolesi

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best…

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature…

This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221). Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz.…

Reflection measurements give access to the complex impedance of a material on a wide frequency range. This is of interest to study the dynamical properties of various materials, for instance disordered superconductors. However reflection…

Instrumentation and Detectors · Physics 2015-06-17 P. Diener , F. Couëdo , C. Marrache-Kikuchi , M. Aprili , J. Gabelli

The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70…

Instrumentation and Methods for Astrophysics · Physics 2010-01-27 M. Tomasi , B. Cappellini , A. Gregorio , F. Colombo , M. Lapolla , L. Terenzi , G. Morgante , M. Bersanelli , R. C. Butler , S. Galeotta , N. Mandolesi , M. Maris , A. Mennella , L. Valenziano , A. Zacchei

70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described…

The LFI radiometers use a pseudo-correlation design where the signal from the sky is continuously compared with a stable reference signal, provided by a cryogenic reference load system. The reference unit is composed by small pyramidal…

We describe a cryogenic instrumentation platform incorporating commercially-available field-programmable gate arrays (FPGAs) configured to operate well beyond their specified temperature range. The instrument enables signal routing,…

Instrumentation and Detectors · Physics 2016-01-20 I. D. Conway Lamb , J. I. Colless , J. M. Hornibrook , S. J. Pauka , S. J. Waddy , M. K. Frechtling , D. J. Reilly

Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is…

Trapping ions in Paul traps requires high radio-frequency voltages, which are generated using resonators. When operating traps in a cryogenic environment, an in-vacuum resonator showing low loss is crucial to limit the thermal load to the…

Instrumentation and Detectors · Physics 2016-06-22 Matthias F. Brandl , Philipp Schindler , Thomas Monz , Rainer Blatt

A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…

Instrumentation and Methods for Astrophysics · Physics 2011-09-19 Eric W. Bryerton

The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific…

Instrumentation and Methods for Astrophysics · Physics 2015-03-17 Planck Collaboration , P. A. R. Ade , N. Aghanim , M. Arnaud , M. Ashdown , J. Aumont , C. Baccigalupi , M. Baker , A. Balbi , A. J. Banday , R. B. Barreiro , E. Battaner , K. Benabed , A. Benoit , J. P. Bernard , M. Bersanelli , P. Bhandari , R. Bhatia , J. J. Bock , A. Bonaldi , J. R. Bond , J. Borders , J. Borrill , F. R. Bouchet , B. Bowman , T. Bradshaw , E. Breelle , M. Bucher , C. Burigana , R. C. Butler , P. Cabella , P. Camus , C. M. Cantalupo , B. Cappellini , J. F. Cardoso , A. Catalano , L. Cayon , A. Challinor , A. Chamballu , J. P. Chambelland , J. Charra , M. Charra , L. Y Chiang , C. Chiang , P. R. Christensen , D. L. Clements , B. Collaudin , S. Colombi , F. Couchot , A. Coulais , B. P. Crill , M. Crook , F. Cuttaia , C. Damasio , L. Danese , R. D. Davies , R. J. Davis , P. de Bernardis , G. de Gasperis , A. de Rosa , J. Delabrouille , J. M. Delouis , F. -X. Desert , U. Doerl , K. Dolag , S. Donzelli , O. Dore , M. Douspis , X. Dupac , G. Efstathiou , T. A. Enslin , H. K. Eriksen , F. Finelli , S. Foley , O. Forni , P. Fosalba , J. J. Fourmond , M. Frailis , E. Franceschi , S. Galeotta , K. Ganga , E. Gavila , M. Giard , G. Giardino , Y. Giraud-Heraud , J. Gonzalez-Nuevo , K. M. Gorski , S. Gratton , A. Gregorio , A. Gruppuso , G. Guyot , D. Harrison , G. Helou , S. Henrot-Versille , C. Hernandez-Monteagudo , D. Herranz , S. R. Hildebrandt , E. Hivon , M. Hobson , W. A. Holmes , A. Hornstrup , W. Hovest , R. J. Hoyland , K. M. Huffenberger , U. Israelsson , A. H. Jaffe , W. C. Jones , M. Juvela , E. Keihanen , R. Keskitalo , T. S. Kisner , R. Kneissl , L. Knox , H. Kurki-Suonio , G. Lagache , J. M. Lamarre , P. Lami , A. Lasenby , R. J. Laureijs , C. R. Lawrence , S. Leach , R. Leonardi , C. Leroy , P. B. Lilje , M. Lopez-Caniego , P. M. Lubin , J. F. Macias-Perez , T. Maciaszek , C. J. MacTavish , B. Maffei , D. Maino , N. Mandolesi , R. Mann , M. Maris , E. Martinez-Gonzalez , S. Masi , S. Matarrese , F. Matthai , P. Mazzotta , P. McGehee , P. R. Meinhold , A. Melchiorri , F. Melot , L. Mendes , A. Mennella , M. -A. Miville-Deschenes , A. Moneti , L. Montier , J. Mora , G. Morgante , N. Morisset , D. Mortlock , D. Munshi , A. Murphy , P. Naselsky , A. Nash , P. Natoli , C. B. Netterfield , D. Novikov , I. Novikov , I. J. O'Dwyer , S. Osborne , F. Pajot , F. Pasian , G. Patanchon , D. Pearson , O. Perdereau , L. Perotto , F. Perrotta , F. Piacentini , M. Piat , S. Plaszczynski , P. Platania , E. Pointecouteau , G. Polenta , N. Ponthieu , T. Poutanen , G. Prezeau , M. Prina , S. Prunet , J. L. Puget , J. P. Rachen , R. Rebolo , M. Reinecke , C. Renault , S. Ricciardi , T. Riller , I. Ristorcelli , G. Rocha , C. Rosset , J. A. Rubiino-Martin , B. Rusholme , M. Sandri , D. Santos , B. M. Schaefer , D. Scott , M. D. Seiffert , P. Shellard , G. F. Smoot , J. -L. Starck , P. Stassi , F. Stivoli , V. Stolyarov , R. Stompor , R. Sudiwala , J. -F. Sygnet , J. A. Tauber , L. Terenzi , L. Toffolatti , M. Tomasi , J. -P. Torre , M. Tristram , J. Tuovinen , L. Valenziano , L. Vibert , P. Vielva , F. Villa , N. Vittorio , L. A. Wade , B. D. Wandelt , C. Watson , S. D. M. White , A. Wilkinson , P. Wilson , D. Yvon , A. Zacchei , B. Zhang , A. Zonca

The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands…

CERN is now setting up String 2, a full-size prototype of a regular cell of the LHC arc. It is composed of two quadrupole, six dipole magnets, and a separate cryogenic distribution line (QRL) for the supply and recovery of the cryogen. An…

Instrumentation and Detectors · Physics 2007-05-23 A. Suraci , T. Bager , Ch. Balle , E. Blanco , J. Casas , P. Gomes , S. Pelletier , L. Serio , N. Vauthier

RFI mitigation in Radioastronomy can be achieved adopting cryogenic filters in appropriate typologies. A study has been conducted in L, C and X band with the evaluation of the filter architecture in copper, with theoretical estimation,…

Astrophysics · Physics 2007-05-23 G. Tuccari , A. Caddemi , S. Barbarino , G. Nicotra , F. Consoli , F. Schilliro , F. Catalfamo

Cryogenic test facilities are critical infrastructure for physics experiments in a variety of fields, perhaps most notably for particle detection with noble liquid detectors, low-temperature device development, and quantum information…

‹ Prev 1 2 3 10 Next ›